The X-IFU is the cryogenic spectrometer onboard the future ATHENA X-ray observatory. It is based on a large array of TES microcalorimeters, which work in combination with a Cryogenic AntiCoincidence detector (CryoAC). This is necessary to reduce the particle background level thus enabling part of the mission science goals. Here we present the first joint test of X-IFU TES array and CryoAC Demonstration Models, performed in a FDM setup. We show that it is possible to operate properly both detectors, and we provide a preliminary demonstration of the anti-coincidence capability of the system achieved by the simultaneous detection of cosmic muons.
20 December 2019 in Journal of Low Temperature Physics
The determination of the absolute neutrino mass scale remains a fundamental open question in particle physics, with profound implications for both the standard model and cosmology. Direct kinematic measurements, independent of model-dependent assumptions, provide the most robust approach to address this challenge. Here we present the most stringent upper bound on the effective electron neutrino mass ever obtained with a calorimetric measurement of the electron capture decay of Ho 163 . The HOLMES experiment employs an array of ion-implanted transition-edge sensor (TES) microcalorimeters, achieving an average energy resolution of 6 eV FWHM with a scalable, multiplexed readout technique. With a total of 7 × 10 7 decay events recorded over two months and a Bayesian statistical analysis, we derive an upper limit of m β < 27 eV / c 2 at 90% credibility. These results validate the feasibility of Ho 163 calorimetry for next-generation neutrino mass experiments and demonstrate the potential of a scalable TES-based microcalorimetric technique to push the sensitivity of direct neutrino mass measurements beyond the current state of the art.
Athena (advanced telescope for high-energy astrophysics) is an ESA large-class mission, at present under a re-definition “design-to-cost” phase, planned for a prospective launch at L1 orbit in the second half of the 2030s. It will be an observatory alternatively focusing on two complementary instruments: the X-IFU (X-ray Integral Field Unit), a TES (TransitionEdge Sensor)-based kilo-pixel array which is able to perform simultaneous high-grade energy spectroscopy (~3 eV@7 keV) and imaging over 4′ FoV (field of view), and the WFI (Wide Field Imager), which has good energy spectral resolution (~170 eV@7 keV) and imaging on wide 40′ × 40′ FoV. Athena will be a truly transformational observatory, operating in conjunction with other large observatories across the electromagnetic spectrum available in the 2030s like ALMA, ELT, JWST, SKA, CTA, etc., and in multi-messenger synergies with facilities like LIGO A+, Advanced Virgo+, LISA, IceCube and KM3NeT. The Italian team is involved in both instruments. It has the co-PIship of the cryogenic instrument for which it has to deliver the TES-based Cryogenic AntiCoincidence detector (CryoAC) necessary to guarantee the X-IFU sensitivity, degraded by a primary particle background of both solar and galactic cosmic ray (GCR) origins, and by secondary electrons produced by primaries interacting with the materials surrounding the main detector. The outcome of Geant4 studies shows the necessity for adopting both active and passive techniques to guarantee the residual particle background at 5 × 10−3 cts cm−2 s−1 keV−1 level in 2–10 keV scientific bandwidth. The CryoAC is a four-pixel detector made of Si-suspended absorbers sensed by Ir/Au TESes placed at <1 mm below the main detector. After a brief overview of the Athena mission, we will report on the particle background reduction techniques highlighting the impact of the Geant4 simulation on the X-IFU focal plane assembly design, then hold a broader discussion on the CryoAC program in terms of detection chain system requirements, test, design concept against trade-off studies and programmatic.