Xiaomei Lin

Xiaomei Lin


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2022 in Journal of Electronic Imaging
Verified
Journal Article
Closed access
PDF file
JFJian Fang
Jian Fang
XLXiaomei Lin
Xiaomei Lin
JTJia Tian
Jia Tian
YWYue Wu
Yue Wu
With the rapid development of electronic computers and information technology, face recognition is widely used in fields such as enterprises, entertainment, information security, and daily life. However, the current face recognition technology is still relatively poor in distinguishing facial features, resulting in a low accuracy of face recognition, which cannot meet increasing application requirements. For this reason, it is necessary to develop more accurate face recognition technology. Residual neural network (ResNet) neural network is a deep residual learning convolutional neural network, which can be used to solve the degeneration problem (i.e., after adding more layers to the neural network, the performance drops rapidly) of deep-learning neural networks. We aim to study the specific principles, calculation methods, and characteristics of the ResNet neural network, analyze the complexity of the classroom environment, propose the use of ResNet network for face feature extraction, and use additive angular margin loss for deep face recognition (ArcFace) as the loss function of the ResNet network to improve the ResNet network. Because the ArcFace function has the advantages of high performance, easy programming, low complexity and high training efficiency. We use this scheme to conduct field tests of face recognition on many students in the classroom. The test results show that this scheme enhances the discrimination of facial features and improves the accuracy of face recognition. In the case of different numbers of people, facial defects, and strong light exposure, the system can still detect and recognize faces stably. In the case of facial defects, the recognition accuracy rate is still 63.3%, and the recognition accuracy rate is still more than 60% under the illumination of strong light, and the recognition accuracy rate under correct conditions is more than 70%.

23 March 2026 in Processes
Verified
Journal Article
Open access
PDF file
LYLei Yu
Lei Yu
LALingling An
Lingling An
XLXiaomei Lin
Xiaomei Lin
Kai-Hung LuKai-Hung Lu
Kai-Hung Lu
HZHongqing Zheng
Hongqing Zheng
As modern power markets integrate more renewable generation, day-ahead energy clearing remains the central procurement step, while flexibility products are procured to ensure that the cleared energy schedule can be operated securely. This paper proposes a closed-loop framework linking the Power Exchange (PX) and the Independent System Operator (ISO) to bridge energy-market settlement and network-feasible operation. The PX performs staged day-ahead clearing with energy settled first, followed by aAutomatic generation control (AGC) and spinning reserve (SR) procured from the residual headroom of committed (energy-awarded) units. The ISO then validates the cleared schedule using an equivalent current injection (ECI)-based screening. This paper uses a single-period (single-hour) IEEE 30-bus case setting; multi-period scheduling and intertemporal constraints are not modeled. When congestion is detected, power-flow tracing identifies the main contributors and guides a minimal-change redispatch. The ISO-feasible dispatch is then sent back to the PX for re-clearing, aligning prices and welfare with an executable operating point. The resulting nonconvex clearing problems with valve-point effects and prohibited operating zones are solved by Artificial Protozoa Optimizer with Social Learning (APO–SL) and evaluated against representative metaheuristic baselines. IEEE 30-bus studies show that off-peak and average-load cases pass ISO screening directly, whereas the peak case tightens reserve headroom (SR capped at 39.08 MW) and triggers congestion. After ISO feedback and energy re-clearing, line loadings return within limits. The ISO-feasible dispatch changes the marginal accepted offer and lifts the MCP (3.73 → 4.38 $/MWh). The welfare value reported here follows the paper’s settlement-based definition (purchase total minus accepted offer cost), and it increases accordingly (113.77 → 190.17 $/h).

8 July 2026 in Processes
Verified
Journal Article
Open access
PDF file
Kai-Hung LuKai-Hung Lu
Kai-Hung Lu
WQWenjun Qian
Wenjun Qian
JWJiajue Wu
Jiajue Wu
LYLei Yu
Lei Yu
LALingling An
Lingling An
XLXiaomei Lin
Xiaomei Lin
Low-carbon OPF studies usually include carbon cost or emission limits in generation-side dispatch, while carbon-accounting studies often evaluate emissions after dispatch. The link between transmission-side flow control and carbon settlement has received less attention. In particular, it remains unclear how UPFC-driven changes in branch flows and losses should affect allowance balance, trading volume, and settlement cost in preventive OPF. This paper therefore proposes a transmission-state-dependent carbon-trading settlement method for UPFC-assisted preventive OPF. Different from post-dispatch carbon accounting, the proposed method calculates carbon-trading quantities from the same network-feasible dispatch solution that determines UPFC-regulated flows, network losses, thermal generation, and contingency feasibility. The model is written in equivalent current injection form. A social-learning artificial bee colony algorithm with feasibility repair is used to solve the constrained problem, with infeasible trial solutions repaired according to power-balance, operating-limit, and carbon-trading constraints. The Taipower 345 kV transmission system is used for testing. Under the annual average daily load condition, line losses are reduced from 27,126.55 MWh to 21,281.92 MWh, while carbon emissions decrease from 300,988.72 tCO2 to 279,527.70 tCO2, corresponding to reductions of 21.55% and 7.13%. The generator-side profit remains positive at TWD 11,000,763. The combined UPFC-PCOPF case also satisfies the screened post-contingency line-loading and voltage constraints. The full-year cases show a similar reduction pattern. These results suggest that carbon-trading settlement is not a fixed post-dispatch accounting item. In UPFC-assisted dispatch, it is linked to transmission losses and thermal generation.

1 September 2026 in Electronics
Verified
Journal Article
Open access
PDF file
LYLei Yu
Lei Yu
YCYongjin Chen
Yongjin Chen
QXQiaoyun Xu
Qiaoyun Xu
Kai-Hung LuKai-Hung Lu
Kai-Hung Lu
LALingling An
Lingling An
XLXiaomei Lin
Xiaomei Lin
Power-electronic converter control is a key issue in the weak-grid integration of doubly fed induction generator (DFIG)-based offshore wind farms. In conventional fixed-reference DFIG control, the rotor-side power command is usually treated as a tracking target, although its suitability may change with the present point of common coupling (PCC) voltage and phase-angle condition. This paper proposes a weak-grid dynamic sensitivity-based model reference governor (WG-DSMRG) for DFIG offshore wind-farm converter control. The governor is inserted upstream of the RSC power-reference path, while the conventional RSC/GSC current controllers, phase-locked loop (PLL), coordinate transformations, and modulation structure are retained. The short-horizon relation between wind-farm power variation and PCC voltage-angle response is estimated from measured electrical signals. The RSC power command is then corrected through weak-grid scheduling and converter-capability projection. A 60-MW offshore DFIG wind farm connected to a weak AC grid is tested under an upstream voltage sag and a PCC single-line-to-ground fault. In the tested cases, the PCC reactive-power peak decreases from about 3.5 Mvar to 2.5 Mvar, and the DC-link voltage peak is reduced under both disturbances. The evaluated PCC voltage and current THD values are also lower with the proposed controller. These results show that reference-layer correction can improve weak-grid integration and power quality without replacing the established DFIG converter-control platform.

15 October 2026 in Electronics
Verified
Journal Article
Open access
PDF file
LYLei Yu
Lei Yu
LALingling An
Lingling An
Song WanqingSong Wanqing
Song Wanqing
XLXiaomei Lin
Xiaomei Lin
PCPiercarlo Cattani
Piercarlo Cattani
Since the degradation process of IGBTs is a slowly varying nonstationary stochastic process with random switching among three modes (active region, saturation region, and cut-off region), remaining useful life (RUL) prediction of IGBTs remains an urgent research issue. This paper investigates IGBT RUL prediction under DC voltage-controlled operating conditions. First, a health feature parameter (HFP) is constructed via the weighted linear combination of gate voltage, collector voltage, and temperature for fault feature extraction of degradation processes. Second, the Markov state transition matrix describing the three operating modes of IGBTs is established. Furthermore, a long-range dependent fractional Weibull process (fWp) prognostic model with three-mode characteristics is developed. Finally, validation is carried out on the public NASA IGBT thermal overload aging dataset. Error analysis demonstrates that the proposed method achieves superior prediction accuracy compared with four prognostic approaches: APE, OSGP, TDNN-GP, and SA-NN.