Radiation is important for the propagation of streamers in dielectric liquids. Photoionization is a possibility, but the effect is difficult to differentiate from other contributions. In this work, we model radiation from the streamer head, causing photoionization when absorbed in the liquid. We find that photoionization is local in space (μm-scale). The radiation absorption cross section is modeled considering that the ionization potential (IP) is dependent on the electric field. The result is a steep increase in the ionization rate when the electric field reduces the IP below the energy of the first electronically excited state, which is interpreted as a possible mechanism for changing from slow to fast streamers. By combining a simulation model for slow streamers based on the avalanche mechanism with a change to fast mode based on a photoionization threshold for the electric field, we demonstrate how the conductivity of the streamer channel can be important for switching between slow and fast streamer propagation modes.
Propagation of positive streamers in dielectric liquids, modeled by the electron avalanche mechanism, is simulated in a needle–plane gap. The streamer is modeled as an RC-circuit where the channel is a resistor and the extremities of the streamer have a capacitance towards the plane. The addition of the RC-model introduces a time constant to the propagation model. Increase in capacitance as a streamer branch propagates reduces its potential, while conduction through the streamer channel increases its potential, as a function of the time constant of the RC-system. Streamer branching also increases the capacitance and decreases the potential of the branches. If the electric field within the streamer channel exceeds a threshold, a breakdown occurs in the channel, and the potential of the streamer is equalized with the needle electrode. This is interpreted as a re-illumination. According to this model, a low conductive streamer branch can propagate some distance before its potential is reduced to below the propagation threshold, and then the RC time constant controls the streamer propagation speed. Channel breakdowns, or re-illuminations, are less frequent when the channels are conductive and more frequent for more branched streamers.
The electrification of society, increasing renewable energy sources and mobility charging lead to new loading patterns for power transformers. Dynamic load conditions induce enhanced mechanical stress on the transformers’ windings, potentially causing degradation of the solid insulation over time and compromising the transformer’s short-circuit withstand capability. Thermal expansion of the windings, caused by losses in the copper conductors, occurring as the transformer is loaded, increases the stress. Conversely, magnetic losses in the core and tie plate expansion contribute to a reduction in stress. This paper presents the effect of step changes in core losses and copper losses by on-line measurements of the clamping pressure, to better understand the mechanical stresses acting upon the solid insulation cellulose materials. Energisation is found to decrease the clamping pressure following warming up of the transformer, and loading the transformer increased the pressure as the windings increased in temperature. The converse effect was found when unloading and de-energising. The on-line monitoring system provides a new and important step towards ensuring the short-circuit performance of power transformers.
Molecular properties are important to consider when designing dielectric liquids because breakdown properties are governed by molecular processes such as ionization. The molecular ionization potential varies with applied field strength, as the positive and negative charge centers in the molecule are separated when subject to an applied electric field, aiding ionization. In this work, we apply an analytical expression for the field-dependent molecular ionization potential based on a Taylor expansion of the molecular charge distribution to six representative molecules: cyclohexane, pyrene, N,N-dimethylaniline, trans-azobenzene, butylated hydroxytoluene and trans-5methyl-3-heptene. Thus, the field dependent molecular ionization potential may be calculated from zero-field properties, namely the molecular energy, dipole moment and polarizability. Vertical and adiabatic ionization potentials are calculated. This model replicates results found with other quantum chemical calculations up to 30 MV/cm, with notable exceptions for trans-azobenzene and N,Ndimethylaniline. The model works reasonably well in the field range 0 to 50 MV/cm, which is considered relevant for fields experienced during dielectric breakdown in transformer insulation liquids. The classical Frenkel term is sufficient to calculate the field-dependent ionization potential at this field range, as additional contributions are generally below ± 0.3 eV compared to the Frenkel term, which is 3.39 eV for all molecules at 20 MV/cm. The difference between the vertical and adiabatic ionization potential is between 0.57 and 0.11 eV for the aforementioned field range, compared to gas-phase ionization potentials of around 7-10 eV.
Molecular properties are important to consider when designing dielectric liquids because breakdown properties are governed by molecular processes such as ionization. The molecular ionization potential varies with applied field strength, as the positive and negative charge centers in the molecule are separated when subject to an applied electric field, aiding ionization. In this work, we apply an analytical expression for the field-dependent molecular ionization potential based on a Taylor expansion of the molecular charge distribution to six representative molecules: cyclohexane, pyrene, N,N-dimethylaniline, trans-azobenzene, butylated hydroxytoluene and trans-5methyl-3-heptene. Thus, the field dependent molecular ionization potential may be calculated from zero-field properties, namely the molecular energy, dipole moment and polarizability. Vertical and adiabatic ionization potentials are calculated. This model replicates results found with other quantum chemical calculations up to 30 MV/cm, with notable exceptions for trans-azobenzene and N,Ndimethylaniline. The model works reasonably well in the field range 0 to 50 MV/cm, which is considered relevant for fields experienced during dielectric breakdown in transformer insulation liquids. The classical Frenkel term is sufficient to calculate the field-dependent ionization potential at this field range, as additional contributions are generally below ± 0.3 eV compared to the Frenkel term, which is 3.39 eV for all molecules at 20 MV/cm. The difference between the vertical and adiabatic ionization potential is between 0.57 and 0.11 eV for the aforementioned field range, compared to gas-phase ionization potentials of around 7-10 eV.