Additive manufacturing (AM) of metals has gained attention as a technology to rapidly produce complex components while reducing waste generated by traditional manufacturing methods. The corrosion properties of AM alloys are not well understood and merit further exploration. The goal of this study is to compare the atmospheric corrosion susceptibility of printed Al-10Si-Mg alloy to its cast counterpart over a range of heat treatments, including as-produced, T5, and T6 tempers. Atmospheric corrosion testing was performed in a salt-fog chamber using a modified G85-A2 cycle for 31 d. Additionally, potentiodynamic testing was used to assess the kinetics of each sample type in dilute Harrison’s solution. Comparison of corrosion damage revealed that cast and AM samples of similar temper had similar damage frequency and average damage depth, but AM samples had greater maximum depths. In as-built and T5 tempers, the AM samples showed preferential attack of the melt pool boundaries. The corrosion was dominated by a dissolution of Al that appeared to favor a path of least resistance through coarser or more discontinuous regions of the Si network at the melt pool boundary. The heat treatment protocol for the T6 temper removed the melt pool structure and resulted in a more general, and more severe, attack because the Si network was no longer present to impede dissolution. Heat treatments after printing were found to be deleterious to the atmospheric corrosion resistance of AM Al-10Si-Mg alloy.
In this work, the effects of tool bias as a processing parameter on an additive friction stir deposition repair of AA7050-T7451 plates were investigated. In this study, the asymmetrical material flow effect was assessed by subjecting a machined groove plate to different tool biases during the AFSD process. The tool bias effectiveness on repairs was quantified through mechanical testing and destructive and non-destructive evaluation. Monotonic tensile tests conducted in parallel with a digital image correlation method captured the mechanical performance of the repairs and the local strain effects of the heat-affected zone. X-ray computed tomography images of the different tool bias repairs were analyzed for any voids or defects to measure the overall bonding effectiveness. The results suggest that the advancing side tool bias had adequate bonding with the substrate, which yielded improved mechanical performance compared to the centered and retreating side depositions.
This paper investigates the effect of the microstructure on the corrosion behavior of cold sprayed (CS) AA5083 compared to its wrought counterpart. It has been shown that the microstructure of CS aluminum alloys, such as AA2024, AA6061, and AA7075, affects their corrosion behavior; however, investigations of the corrosion behavior of CS AA5083 with a direct comparison to wrought AA5083 have been limited. The microstructure and corrosion behavior of CS AA5083 were examined by scanning electron microscopy (SEM), transmission electron microscopy (TEM), energy dispersive X-ray spectroscopy (EDS), electron backscattered diffraction (EBSD), electrochemical and immersion tests, and ASTM G67. The CS process resulted in microstructural changes, such as the size and spatial distribution of intermetallic particles, grain size, and misorientation. The refined grain size and intermetallic particles along prior particle boundaries stimulated the initiation and propagation of localized corrosion. Electrochemical tests presented enhanced anodic kinetics with high pitting susceptibility, giving rise to extensive localized corrosion in CS AA5083. The ASTM G67 test demonstrated significantly higher mass loss for CS AA5083 compared to its wrought counterpart due to preferential attack within prior particle boundary regions in the CS microstructure. Possible mechanisms of intergranular corrosion (IGC) propagation at prior particle boundary regions have been discussed.
This paper investigates the initiation and propagation of localized corrosion on cold-sprayed (CS) aluminum alloy 2024 and 7075 deposits. CS deposits on AA2024-T351 and AA7075-T651 substrates were produced with commercially available AA2024 and AA7075 powders using helium as carrier gas. Electrochemical and immersion tests in 0.6 M NaCl and ASTM G110 test were used to evaluate the corrosion properties of CS AA2024 and AA7075 deposits. For analysis, optical microscopy, scanning electron microscopy, energy dispersive x-ray spectroscopy, and x-ray diffraction were utilized before and after the experiment. The results indicated that the initiation and propagation of localized corrosion highly depend on microstructural characteristics, such as the distribution and chemical composition of intermetallic networks with the matrix and propagated along these networks and prior particle boundaries, where an ultrafine grain structure is present. Accelerated localized corrosion tests generated deep penetration as well as a large area of defects owing to the coalescence of fissures.
30 December 2024 in Metallurgical and Materials Transactions A