Takumi Kobayashi

Dr. Takumi Kobayashi


Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 January 2024 in Electronics
Verified
Journal Article
Open access
PDF file
JHJunya Hoshino
Junya Hoshino
JHJaakko Hyry
Jaakko Hyry
TKTakumi Kobayashi
Takumi Kobayashi
DADaisuke Anzai
Daisuke Anzai
Managing medication status solves related complications and prevents increases in medical costs due to the improper management of prescriptions. An ingestible sensor can be used to confirm a patient’s real-time medical status by measuring the electromagnetic waves transmitted from an ingested medication from outside of the human body. However, concerns about costs of delivery arise, as it would be necessary to attach a sensor to each ingested medication. In this study, we focused on using an electromagnetic (EM) imaging method which can estimate the internal structure of various objects using a scattered electric field. With this method we can detect medication as it does not require the installation of a sensor. At first we performed an electromagnetic field simulation and based on the results we experimentally measured the external electric field, which changes with the medicine. Then, we evaluated the accuracy of the detection method by calculating the difference between the detection rate with the proposed detection method against a more conventional method. The results indicate the possibility of achieving a more than 20% higher accuracy than the conventional detection method with our proposed method using electromagnetic waves.

16 August 2024 in Information
Verified
Journal Article
Open access
PDF file
MFMitsuhiro Fukuda
Mitsuhiro Fukuda
JHJaakko Hyry
Jaakko Hyry
RORyosuke Omoto
Ryosuke Omoto
TSTakunori Shimazaki
Takunori Shimazaki
TKTakumi Kobayashi
Takumi Kobayashi
DADaisuke Anzai
Daisuke Anzai
Accurately obtaining a patient’s respiratory rate is crucial for promptly identifying any sudden changes in their condition during emergencies. Typically, the respiratory rate is assessed through a combination of impedance change measurements and electrocardiography (ECG). However, impedance measurements are prone to interference from body movements. Conversely, a capnometer coupled with a ventilator offers a method of measuring the respiratory rate that is unaffected by body movements. However, capnometers are mainly used to evaluate respiration when using a ventilator or an Ambu bag by measuring the CO2 concentration at the breathing circuit, and they are not used only to measure the respiratory rate. Furthermore, capnometers are not suitable as wearable devices because they require intubation or a mask that covers the nose and mouth to prevent air leaks during the measurement. In this study, we developed a reliable system for measuring the respiratory rate utilizing a small wearable MOx sensor that is unaffected by body movements and not connected to the breathing circuit. Subsequently, we conducted experimental assessments to gauge the accuracy of the rate estimation achieved by the system. In order to avoid the effects of abnormal states on the estimation accuracy, we also evaluated the classification performance for distinguishing between normal and abnormal respiration using a one-class SVM-based approach. The developed system achieved 80% for both true positive and true negative rates. Our experimental findings reveal that the respiratory rate can be precisely determined without being influenced by body movements.