Jaakko Hyry

Dr. Jaakko Hyry

Graduate school of engineering, Nagoya Institute of Technology, Nagoya, Aichi, Japan
orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 August 2024 in Sensors
Verified
Journal Article
Open access
PDF file
RIRumi Iwai
Rumi Iwai
TSTakunori Shimazaki
Takunori Shimazaki
JHJaakko Hyry
Jaakko Hyry
YKYoshifumi Kawakubo
Yoshifumi Kawakubo
MFMasashi Fukuhara
Masashi Fukuhara
DADaisuke Anzai
Daisuke Anzai
Hemodialysis therapy is an extracorporeal circulation treatment that serves as a substitute for renal function. In Japan, patients receive this efficient four-hour treatment, three times per week, allowing them to maintain a social life nearly equivalent to that of healthy individuals. Before the treatment, two punctures are performed to establish extracorporeal circulation, and a high blood flow rate is essential to ensure efficient therapy. Specialized blood vessels created through arteriovenous fistula (AVF) surgery are utilized to achieve high blood flow rates. Although the AVF allows safe and efficient dialysis treatment, AVF stenosis leads to a serious problem in dialysis. To early detect this abnormal blood flow, auscultation and palpation methods are widely used in hospitals. However, these methods can only provide qualitative judgment of the AVF condition, so the results cannot be shared among other doctors and staff. Additionally, since the conventional methods require contact with the skin, some issues require consideration regarding infection and low reproducibility. In our previous study, we proposed an alternative method for auscultation using non-contact optical imaging technology. This study aims to construct a reliable AVF stenosis detection method using Thrill waveform analysis based on the developed non-contact device to solve the problem with the contact palpation method. This paper demonstrates the performance validation of the non-contact imaging in the normal AVF group (206 total data, 75 patients, mean age: 69.1 years) and in the treatable stenosis group (107 total data, 17 patients, mean age: 70.1 years). The experimental results of the Mann–Whitney U test showed a significant difference (p=0.0002) between the normal and abnormal groups, which indicated the effectiveness of the proposed method as a new possible alternative to palpation.

29 January 2024 in Electronics
Verified
Journal Article
Open access
PDF file
JHJunya Hoshino
Junya Hoshino
JHJaakko Hyry
Jaakko Hyry
TKTakumi Kobayashi
Takumi Kobayashi
DADaisuke Anzai
Daisuke Anzai
Managing medication status solves related complications and prevents increases in medical costs due to the improper management of prescriptions. An ingestible sensor can be used to confirm a patient’s real-time medical status by measuring the electromagnetic waves transmitted from an ingested medication from outside of the human body. However, concerns about costs of delivery arise, as it would be necessary to attach a sensor to each ingested medication. In this study, we focused on using an electromagnetic (EM) imaging method which can estimate the internal structure of various objects using a scattered electric field. With this method we can detect medication as it does not require the installation of a sensor. At first we performed an electromagnetic field simulation and based on the results we experimentally measured the external electric field, which changes with the medicine. Then, we evaluated the accuracy of the detection method by calculating the difference between the detection rate with the proposed detection method against a more conventional method. The results indicate the possibility of achieving a more than 20% higher accuracy than the conventional detection method with our proposed method using electromagnetic waves.

22 November 2024 in IEEE Access
Verified
Journal Article
Open access
DADaisuke Anzai
Daisuke Anzai
HKHisato Kobayashi
Hisato Kobayashi
JHJaakko Hyry
Jaakko Hyry
TKTakumi Kobayashi
Takumi Kobayashi
JKJens Kirchner
Jens Kirchner
Georg FischerGeorg Fischer
Georg Fischer
To improve the quality of medical treatment using implantable devices, accurate location information for implantable devices must be acquired and reliable implant communications for vital data transmission must be ensured. This paper focuses on an electromagnetic (EM) imaging-based method using scattered EM fields, which enables implant device localization without requiring any information regarding the human body structure. However, in conventional EM imaging-based methods, it is difficult to accurately estimate the capsule location at high frequencies because of significant signal attenuation. Herein, we propose an EM imaging-based localization method enhanced by peak-formed incident electric fields generated by overlaying multiple EM waves. Our proposed method utilizes information regarding scattered electric fields by sweeping the peak location without increasing the measurement points. The performance improvement by the proposed method was evaluated in two- and three-dimensional computer simulations such that the proposed EM imaging-based localization can be further optimized to achieve precise estimation accuracy at a high frequency of 2.4 GHz.

16 July 2025 in Sensors
Verified
Journal Article
Open access
PDF file
MTMasanobu Tsurumoto
Masanobu Tsurumoto
TSTakunori Shimazaki
Takunori Shimazaki
JHJaakko Hyry
Jaakko Hyry
YKYoshifumi Kawakubo
Yoshifumi Kawakubo
TYTakeshi Yokoyama
Takeshi Yokoyama
DADaisuke Anzai
Daisuke Anzai
Peripheral circulatory failure refers to a condition in which the blood flow through superficial capillaries is markedly reduced or completely occluded. In clinical practice, nurses strictly adhere to regular repositioning protocols to prevent peripheral circulatory failure, during which the skin condition is evaluated visually. In this study, skin colour changes resulting from pressure application were continuously captured using a camera, and supervised machine learning was employed to classify the data into two categories: before and after pressure. The evaluation of practical colour space components revealed that the h component of the JCh colour space demonstrated the highest discriminative performance (Area Under the Curve (AUC) = 0.88), followed by the a* component of the CIELAB colour space (AUC = 0.84) and the H component of the HSV colour space (AUC = 0.83). These findings demonstrate that it is feasible to quantitatively evaluate skin colour changes associated with pressure, suggesting that this approach can serve as a valuable indicator for dimensionality reduction in feature extraction for machine learning and is potentially an effective method for preventing pressure-induced skin injuries.

5 May 2024
Verified
Book Chapter
Open access
PDF file
JHJaakko Hyry
Jaakko Hyry
PKPasi Karppinen
Pasi Karppinen
TKTakumi Kobayashi
Takumi Kobayashi
DADaisuke Anzai
Daisuke Anzai
The Japanese and Finnish healthcare systems have several longstanding challenges from the scattered data in storing databases due to location sensitivity and sometimes unequal services for their users. In addition to the data itself, location plays another role for the citizens living in urban or rural areas. They suffer from different well-being outcomes as stress and sedentary lifestyles have presented negative impacts on the urban dwellers. As remote work and technological solutions have become more common, in this conceptual research, we explore the general healthcare and living area challenges and how to make services more equal to everyone. We also discuss the possible telehealth solutions and how, for example, wearable body sensors’ use could offer improvements to the availability and accessibility of healthcare services.

1 September 2026 in IEEE Journal of Electromagnetics, RF and Microwaves in Medicine and Biology
Verified
Journal Article
Open access
TKTakumi Kobayashi
Takumi Kobayashi
JHJaakko Hyry
Jaakko Hyry
MFManato Fujimoto
Manato Fujimoto
SAShingo Ata
Shingo Ata
DADaisuke Anzai
Daisuke Anzai
It is important to determine efficient transmit power for ultra-wideband (UWB) communications, especially in implantable medical devices, to overcome large signal attenuation from a human body and to ensure reliable high-speed transmission. This paper investigates the optimization of transmit pulse waveform to improve the communication characteristics under two regulations: extremely low power (ELP) regulation and specific absorption rate (SAR). Furthermore, a sparse control method is introduced to further optimize the balance between the performance and system complexity for medical implant applications. The proposed system achieved an average throughput of 40.3 Mbps as compared with the average throughput of 5.7 Mbps of the conventional UWB communication system.