Mahdieh Yariesbouei

Dr. Mahdieh Yariesbouei


Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 January 2024 in Micromachines
Verified
Journal Article
Open access
PDF file
MYMahdieh Yariesbouei
Mahdieh Yariesbouei
RSRemco G. P. Sanders
Remco G. P. Sanders
RWRemco Wiegerink
Remco Wiegerink
JLJoost Lötters
Joost Lötters
This paper presents the first nickel-plated micro-Coriolis mass-flow sensor with integrated optical readout. The sensor consists of a freely suspended tube made of electroplated nickel with a total length of 60 mm, an inner diameter of 580 µm, and a wall thickness of approximately 8 µm. The U-shaped tube is actuated by Lorentz forces. An optical readout consisting of two LEDs and two phototransistors is used to detect the tube motion. Mass-flow measurements were performed at room temperature with water and isopropyl alcohol for flows up to 200 g/h and 100 g/h, respectively. The measured resonance frequencies were 1.67 kHz and 738 Hz for water and 1.70 kHz and 752 Hz for isopropyl alcohol for the twist and swing modes, respectively. The measured phase shift between the two readout signals shows a linear response to mass flow with very similar sensitivities for water and isopropyl alcohol of 0.41mdegg/h and 0.43 mdegg/h, respectively.

12 December 2024 in Sensors
Verified
Journal Article
Open access
PDF file
QYQihui Yu
Qihui Yu
MBMaarten Jan Sijmen Bonnema
Maarten Jan Sijmen Bonnema
MYMahdieh Yariesbouei
Mahdieh Yariesbouei
RWRemco Wiegerink
Remco Wiegerink
JLJoost Lötters
Joost Lötters
This paper introduces a Coriolis mass flow and density sensor. The sensor is made using Surface Channel Technology (SCT) but with selective wet etching to create the channels. This method forms suspended microfluidic channels with a larger cross-sectional area. Because of this larger cross-sectional area, the sensor has a much higher flow range, up to 50 g h−1 (for water) with a pressure drop of 1 bar, compared to the standard SCT-based Coriolis sensor, which is only 1.2 g h−1. The channel has a semi-elliptical cross-sectional area, measuring 200 micrometers wide and 70 micrometers deep. The channel wall is made of a stack of thin films with a total thickness of 2.5 μm. Water, isopropyl alcohol (IPA), and nitrogen (N2) are used to test and evaluate the sensor’s mass flow and density sensing performance.