This paper reports a flow-through sensor for the real-time measurement of the relative permittivity of a flowing fluid. The proposed sensor contains multiple parallel microchannels. Each channel acts as a parallel plate capacitor in which the electrodes are isolated from the fluid. This approach results in a low pressure drop and high sensitivity while the internal volume is only 50 nl. The fabrication technology allows for controllable scaling of the channel geometry. Equally deep microchannels with widths varying between 5 µm and 50 m are fabricated. The fabrication technology is compatible with other flow-through sensors, enabling further on-chip integration. The sensor has been characterised using 10 different fluids with relative permittivity values ranging from 1 to 80—including water and water-containing mixtures—at a measurement frequency of 300 kHz. The results show an accuracy within 3% of full scale and the repeated measurements with nitrogen and water show standard deviations of 1.20 and 1.03, respectively.
This paper introduces a Coriolis mass flow and density sensor. The sensor is made using Surface Channel Technology (SCT) but with selective wet etching to create the channels. This method forms suspended microfluidic channels with a larger cross-sectional area. Because of this larger cross-sectional area, the sensor has a much higher flow range, up to 50 (for water) with a pressure drop of 1 bar, compared to the standard SCT-based Coriolis sensor, which is only 1.2 . The channel has a semi-elliptical cross-sectional area, measuring 200 micrometers wide and 70 micrometers deep. The channel wall is made of a stack of thin films with a total thickness of 2.5 . Water, isopropyl alcohol (IPA), and nitrogen (N2) are used to test and evaluate the sensor’s mass flow and density sensing performance.
25 March 2026 in Sensors and Actuators A: Physical
This paper reports on a microfluidic sensor for inline measurement of the thermal conductivity of liquids at flow rates up to 1 g/h. The sensor contains a highly-doped silicon heater suspended in a 1 mm long microchannel that is 60 μm wide and 60 μm deep. The heater element is positioned 30 μm deep inside the microchannel to increase the contact area with the fluid and to reduce heat losses to the environment. Moreover, cavities at either side are designed to thermally isolate the microchannel, reducing the power consumption of the heater to 10 mW. The sensor is characterised through a range of different binary liquid mixtures, yielding a thermal conductivity range from 0.169 W/(m·K) (ethanol) up to 0.617 W/(m·K) (water). The analytical model coincides closely with the measurements. For practical applications, calibration curves are provided, yielding accuracies within 4% and 5% at 0 g/h and 1 g/h, respectively. Furthermore, the fabrication technology allows for further on-chip integration with other inline microfluidic sensors, which is relevant for compensating the response of microfabricated thermal flow sensors and fluid composition analysis.