Yi Zhang

Yi Zhang


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2017 in Neural Plasticity
Verified
Journal Article
Open access
PDF file
CWCongxiao Wang
Congxiao Wang
YZYi Zhang
Yi Zhang
JDJie Ding
Jie Ding
ZZZhen Zhao
Zhen Zhao
CQCheng Qian
Cheng Qian
GTGao-Jun Teng
Gao-Jun Teng
Aims. Stroke is a leading cause of morbidity and mortality. This study aimed to determine whether nicotinamide administration could improve remyelination after stroke and reveal the underlying mechanism. Methods. Adult male C57BL/6J mice were intraperitoneally (i.p.) administered with nicotinamide (200 mg/kg, daily) or saline after stroke induced by photothrombotic occlusion of the middle cerebral artery. FK866 (3 mg/kg, daily, bis in die), an inhibitor of NAMPT, and ANA-12 (0.5 mg/kg, daily), an antagonist of tropomyosin-related kinase B (TrkB), were administered intraperitoneally 1 h before nicotinamide administration. Functional recovery, MRI, and histological assessment were performed after stroke at different time points. Results. The nicotinamide-treated mice showed significantly lower infarct area 7 d after stroke induction and significantly higher fractional anisotropy (FA) in the ipsilesional internal capsule (IC) 14 d after stroke induction than the other groups. Higher levels of NAD+, BDNF, and remyelination markers were observed in the nicotinamide-treated group. FK866 administration reduced NAD+ and BDNF levels in the nicotinamide-treated group. ANA-12 administration impaired the recovery from stroke with no effect on NAD+ and BDNF levels. Furthermore, lesser functional deficits were observed in the nicotinamide-treated group than in the control group. Conclusions. Nicotinamide administration improves remyelination after stroke via the NAD+/BDNF/TrkB pathway.

1 June 2024 in International Journal of Nanomedicine
Verified
Journal Article
Open access
PDF file
HDHao Du
Hao Du
WLWentao Li
Wentao Li
XLXueyi Li
Xueyi Li
ZQZhiyuan Qiu
Zhiyuan Qiu
JDJie Ding
Jie Ding
YZYi Zhang
Yi Zhang
Background: Poly-L-lactic acid (PLLA) stents have broad application prospects in the treatment of cardiovascular diseases due to their excellent mechanical properties and biodegradability. However, foreign body reactions caused by stent implantation remain a bottleneck that limits the clinical application of PLLA stents. To solve this problem, the biocompatibility of PLLA stents must be urgently improved. Albumin, the most abundant inert protein in the blood, possesses the ability to modify the surface of biomaterials, mitigating foreign body reactions—a phenomenon described as the “stealth effect”. In recent years, a strategy based on albumin camouflage has become a focal point in nanomedicine delivery and tissue engineering research. Therefore, albumin surface modification is anticipated to enhance the surface biological characteristics required for vascular stents. However, the therapeutic applicability of this modification has not been fully explored. Methods: Herein, a bionic albumin (PDA-BSA) coating was constructed on the surface of PLLA by a mussel-inspired surface modification technique using polydopamine (PDA) to enhance the immobilization of bovine serum albumin (BSA). Results: Surface characterization revealed that the PDA-BSA coating was successfully constructed on the surface of PLLA materials, significantly improving their hydrophilicity. Furthermore, in vivo and in vitro studies demonstrated that this PDA-BSA coating enhanced the anticoagulant properties and pro-endothelialization effects of the PLLA material surface while inhibiting the inflammatory response and neointimal hyperplasia at the implantation site. Conclusion: These findings suggest that the PDA-BSA coating provides a multifunctional biointerface for PLLA stent materials, markedly improving their biocompatibility. Further research into the diverse applications of this coating in vascular implants is warranted.

31 January 2024 in Electronics
Verified
Journal Article
Open access
PDF file
TLTao Li
Tao Li
泉曾泉 曾
泉 曾
JLJinbiao Li
Jinbiao Li
CQCheng Qian
Cheng Qian
HYHanmei Yu
Hanmei Yu
SZShoujun Zhou
Shoujun Zhou
The development of a new generation of minimally invasive surgery is mainly reflected in robot-assisted diagnosis and treatment methods and their clinical applications. It is a clinical concern for robot-assisted surgery to use a multi-joint robotic arm performing human ultrasound scanning or ultrasound-guided percutaneous puncture. Among them, the motion control of the robotic arm, and the guiding and contact scanning processes of the ultrasonic (US-) probe determine the diagnosis effect, as well as the accuracy and safety of puncture surgery. To address these challenges, this study developed an intelligent robot-assisted system integrating autonomous US inspection and needle positioning, which has relation to several intelligent algorithms such as adaptive flexible control of the robot arm, autonomous US-scanning, and real-time attitude adjustment of the puncture needle. To improve the cooperativity of the spatial operation of the robot end-effector, we propose an adaptive flexible control algorithm that allows the operator to control the robot arm flexibly with low damping. To achieve the stability and uniformity of contact detection and imaging, we introduced a self-scanning method of US-probe based on reinforcement learning and built a software model of variable stiffness based on MuJoco to verify the constant force and velocity required by the end mechanism. We conducted a fixed trajectory scanning experiment at a scanning speed of 0.06 m/s. The force curve generally converges towards the desired contact force of 10 N, with minor oscillations around this value. For surgical process monitoring, we adopted the puncture needle detection algorithm based on Unet++ to acquire the position and attitude information of the puncture needle in real time. In short, we proposed and verified an adaptive control method and learning strategy by using an UR robotic arm equipped with a US-probe and puncture needle, and we improved the intelligence of the US-guided puncture robot.

22 January 2025 in Chinese Journal of Traumatology
Verified
Journal Article
Open access
SLShuo Leng
Shuo Leng
WLWentao Li
Wentao Li
YCYu Cai
Yu Cai
YZYi Zhang
Yi Zhang
Vasculature injury occurs rarely in traumatic brain injury but increases lifetime risk of ischemic or hemorrhage stroke. The diverse and nonspecific clinical manifestations make the diagnosis and treatment of these injuries highly challenging. With advancements in device design, endovascular treatments have become widely adopted, playing an increasingly vital role in the management of vascular diseases. The purpose of this review is to introduce and summarize endovascular treatments of traumatic cerebrovascular injury and other related pathological states after traumatic brain injury. Given the innovations of neuroendovascular devices and improvements in the techniques over the past decade, this review will outline several recent advancements in endovascular treatment strategies for cerebrovascular pathologies. Popularizing more treatment options to clinicians will benefit in dealing with a variety of clinical scenarios and reduce the overall morbidity of traumatic cerebrovascular injury.

31 May 2025 in Biopolymers
Verified
Journal Article
Closed access
JLJian Lv
Jian Lv
YZYi Zhang
Yi Zhang
RSRenhua Sun
Renhua Sun
XHXue Hu
Xue Hu
RHRixin Hua
Rixin Hua
GZGutian Zhao
Gutian Zhao

11 August 2025 in IEEE Sensors Journal
Verified
Journal Article
Closed access
XJXiaoliang Jin
Xiaoliang Jin
ASAiguo Song
Aiguo Song
JZJianjun Zhu
Jianjun Zhu
CWCheng Wang
Cheng Wang
YZYi Zhang
Yi Zhang
LZLifeng Zhu
Lifeng Zhu
Robot-assisted vascular interventional surgery (VIS) is an advanced treatment method that uses robotic systems to perform remote surgical procedures. Haptic feedback is crucial for restoring the interventionist’s sense of presence, allowing them to effectively operate instruments and accurately perceive surgical status. However, despite recent advancements, the quality of haptic feedback remains inferior to traditional manual operation, potentially compromising operational safety during surgery. Our previous work involved designing and developing a novel haptic feedback-based leader device that aligns with interventionists’ operating habits and accurately reproduces follower-side operating forces. This article further optimizes the leader device to improve haptic feedback. Furthermore, we propose a safe interaction control strategy that integrates force and morphological features of surgical instruments. Compared to existing methods, the proposed strategy incorporates an important control parameter—morphological features of surgical instruments. Verification results confirm this strategy’s effectiveness, enhancing robot system–interventionist interaction. This research has the potential to provide safer and more efficient treatment options.