Richard Fitton

Dr. Richard Fitton

School of Science, Engineering and Environment, University of Salford, Salford, United Kingdom

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 December 2018 in Journal of Medical Internet Research
Verified
Journal Article
Open access
BMBrian McMillan
Brian McMillan
RERobert Eastham
Robert Eastham
BBBenjamin Brown
Benjamin Brown
Richard FittonRichard Fitton
Richard Fitton
DDDavid Dickinson
David Dickinson
Journal of Medical Internet Research - International Scientific Journal for Medical Research, Information and Communication on the Internet #Preprint #PeerReviewMe: Warning: This is a unreviewed preprint. Readers are warned that the document has not been peer-reviewed by expert/patient reviewers or an academic editor, may contain misleading claims, and is likely to undergo changes before final publication, if accepted, or may have been rejected/withdrawn. Readers with interest and expertise are encouraged to sign up as peer-reviewer, if the paper is within an open peer-review period. Please cite this preprint only for review purposes or for grant applications and CVs (if you are the author). This article briefly outlines the history of the medical record and the factors contributing to the adoption of computerised records in primary care in the United Kingdom. It discusses how both paper-based and electronic health records have traditionally been used in the past and goes on to examine how enabling patients to access their own primary care records online is changing the form and function of the patient record. It looks at the evidence for the benefits of online access and discusses some of the challenges faced in this transition. Finally, some suggestions are made regarding the future of the patient record and research questions that need to be addressed to help deepen our understanding of how they can be used more beneficially by both patients and clinicians.

19 March 2018 in Buildings
Verified
Journal Article
Open access
PDF file
AMAlex Marshall
Alex Marshall
JFJohann Francou
Johann Francou
Richard FittonRichard Fitton
Richard Fitton
William SwanWilliam Swan
William Swan
JOJacob Owen
Jacob Owen
MBMoaad Benjaber
Moaad Benjaber
U-values of building elements are often determined using point measurements, where infrared imagery may be used to identify a suitable location for these measurements. Current methods identify that surface areas exhibiting a homogeneous temperature—away from regions of thermal bridging—can be used to obtain U-values. In doing so, however, the resulting U-value is assumed to represent that entire building element, contrary to the information given by the initial infrared inspection. This can be problematic when applying these measured U-values to models for predicting energy performance. Three techniques have been used to measure the U-values of external building elements of a full-scale replica of a pre-1920s U.K. home under controlled conditions: point measurements, using heat flux meters, and two variations of infrared thermography at high and low resolutions. U-values determined from each technique were used to calibrate a model of that building and predictions of the heat transfer coefficient, annual energy consumption, and fuel cost were made. Point measurements and low-resolution infrared thermography were found to represent a relatively small proportion of the overall U-value distribution. By propagating the variation of U-values found using high-resolution thermography, the predicted heat transfer coefficient (HTC) was found to vary between 183 W/K to 235 W/K (±12%). This also led to subsequent variations in the predictions for annual energy consumption for heating (between 4923 kWh and 5481 kWh, ±11%); and in the predicted cost of that energy consumption (between £227 and £281, ±24%). This variation is indicative of the sensitivity of energy simulations to sensor placement when carrying out point measurements for U-values.

29 May 2017 in Energy Efficiency
Verified
Journal Article
Open access
PDF file
Richard FittonRichard Fitton
Richard Fitton
William SwanWilliam Swan
William Swan
THTara Hughes
Tara Hughes
MBMoaad Benjaber
Moaad Benjaber
The residential sector is responsible for 29% of the total energy consumption of the UK, with 62% of this energy being used for space heating. Heat loss through the fabric of building elements is a crucial factor in the energy efficiency of homes, and a wide number of studies have looked at physical interventions to improve the energy efficiency of existing buildings, commonly called retrofit. This research considers the impact of window coverings on reducing heat loss from homes, a measure that is not commonly considered an energy efficiency intervention. Although the amount of glazing varies widely between homes, all windows are a significant factor contributing to heat loss. While physical changes such as double and triple glazing can improve the energy performance of buildings, the impact of curtains and blinds is not well characterised. Previous research into window coverings has been undertaken using laboratory tests, such as hotbox and small climatic chamber environments. This study presents the impact of window coverings on heat loss within a unique whole house test facility. This allows for a better replication of a real heating system and the effects that it has on localised heat transfer. This gives a more detailed picture of in situ performance, similar to that which may be found in the field.

13 November 2017 in International Journal of Building Pathology and Adaptation
Verified
Journal Article
Closed access
William SwanWilliam Swan
William Swan
Richard FittonRichard Fitton
Richard Fitton
LSLuke Smith
Luke Smith
CACarl Abbott
Carl Abbott
LSLiz Smith
Liz Smith
Purpose: The Retrofit State of the Nation Survey has tracked the perceptions of social housing sector professionals’ views of retrofit since 2010. It has taken the form of three surveys conducted in 2010, 2013 and 2015. Here, the authors bring together the three surveys to specifically address the adoption and perceived effectiveness of retrofit technology in social housing projects. The purpose of this paper is to identify the changing perceptions of social housing professionals over a period of significant policy change within in the sector. Design/methodology/approach: The research takes the form of a cross-sectional attitudinal, self-completion survey, covering sections considering the adoption levels and perceived effectiveness of different retrofit technologies. The target sample was medium to larger scale registered social housing providers. The surveys were conducted in 2010, 2013 and 2015. Findings: In terms of effectiveness, the reliance on tried and tested technologies is apparent. Emerging or more complex technologies have declined in perceived effectiveness over the period. It is clear that social housing has adopted a wide range of technologies, and the larger providers, with whom this survey is undertaken, potentially represent a significant pool of UK retrofit experience. Originality/value: The survey provides a record of the changing attitudes of social housing providers to specific technologies over the period of 2010-2015, which has seen significant changes in the energy and social housing policy. The findings show the link between policy instruments and adoption, with policy instruments mapping to adoption in the sector. Perceived effectiveness reflects a preference for more established technologies, an issue that is highlighted in the recent Bonfield Review.

5 June 2025 in Energies
Verified
Journal Article
Open access
PDF file
CTChristopher Tsang
Christopher Tsang
Ljubomir JankovicLjubomir Jankovic
Ljubomir Jankovic
William SwanWilliam Swan
William Swan
Richard FittonRichard Fitton
Richard Fitton
GHGrant Patrick Henshaw
Grant Patrick Henshaw
This study investigates the relative benefits of solar thermal (ST) and photovoltaic (PV) systems integrated with air-source heat pumps for domestic hot water production in newly built residential buildings. Using calibrated DesignBuilder simulations of “The Future Home” located in Energy House 2.0, an environmental chamber, the study analyzes energy performance and carbon emissions for eight scenarios: (1) baseline heat pump only, (2) heat pump with 4 m2 PV panels, (3) heat pump with 4 m2 ST panels, (4) heat pump with 2 m2 PV + 2 m2 ST panels, and (5–8) variants with increased hot water demand. While ST systems directly heat water through thermal energy transfer, PV systems contribute to water heating indirectly by providing electricity to power the heat pump. The results show that the ST system provides 964.6 kWh of thermal energy annually, increasing to 1528 kWh with enhanced hot water demand, while a similarly sized PV system generates 532.5 kWh of electricity. The research reveals that Standard Assessment Procedure methodology’s fixed hot water demand assumptions could significantly underpredict solar thermal benefits, potentially discouraging UK house builders from adopting this technology.

22 July 2025 in Sustainability
Verified
Journal Article
Open access
PDF file
CTChristopher Tsang
Christopher Tsang
Richard FittonRichard Fitton
Richard Fitton
XZXinyi Zhang
Xinyi Zhang
GHGrant Patrick Henshaw
Grant Patrick Henshaw
Heidi Díaz HernándezHeidi Díaz Hernández
Heidi Díaz Hernández
William SwanWilliam Swan
William Swan
This study provides a detailed dataset from two modern homes constructed inside an environmentally controlled chamber. These data are used to carefully calibrate a dynamic thermal simulation model of these homes. The calibrated models show good agreement with measurements taken under controlled conditions. The two case study homes, “The Future Home” and “eHome2”, were constructed within the University of Salford’s Energy House 2.0, and high-quality data were collected over eight days. The calibration process involved updating U-values, air permeability rates, and modelling refinements, such as roof ventilation, ground temperatures, and sub-floor void exchange rates, set as boundary conditions. Results demonstrated a high level of accuracy, with performance gaps in whole-house heat transfer coefficient reduced to 0.5% for “The Future Home” and 0.6% for “eHome2”, falling within aggregate heat loss test uncertainty ranges by a significant amount. The study highlights the improved accuracy of calibrated dynamic thermal simulation models, compared to results from the steady-state Standard Assessment Procedure model. By providing openly accessible calibrated models and a clearly defined methodology, this research presents valuable resources for future building performance modelling studies. The findings support the UK’s transition to dynamic modelling approaches proposed in the recently introduced Home Energy Model approach, contributing to improved prediction of energy efficiency and aligning with goals for zero carbon ready and sustainable housing development.