This paper presents the experimental results on the Terapia Oncologica con Protoni-Intensity Modulated Proton Linear Accelerator (TOP-IMPLART) beam that is currently accelerated up to 35 MeV, with a final target of 150 MeV. The TOP-IMPLART project, funded by the Innovation Department of Regione Lazio (Italy), is led by Italian National Agency for New Technologies, Energy and Sustainable Economic Development (ENEA) in collaboration with the Italian Institute of Health and the Oncological Hospital Regina Elena-IFO. The accelerator, under construction and test at ENEA-Frascati laboratories, employs a commercial 425 MHz, 7 MeV injector followed by a sequence of 3 GHz accelerating modules consisting of side coupled drift tube linac (SCDTL) structures up to 71 MeV and coupled cavity linac structures for higher energies. The section from 7 to 35 MeV, consisting on four SCDTL modules, is powered by a single 10 MW klystron and has been successfully commissioned. This result demonstrates the feasibility of a “fully linear” proton therapy accelerator operating at a high frequency and paves the way to a new class of machines in the field of cancer treatment.
Lithium fluoride (LiF) crystals and thin films are utilized as radiation detectors for energy diagnostics of proton beams. This is achieved by analyzing the Bragg curves in LiF obtained by imaging the radiophotoluminescence of color centers created by protons. In LiF crystals, the Bragg peak depth increases superlinearly with the particle energy. A previous study has shown that, when 35 MeV protons impinge at grazing incidence onto LiF films deposited on Si(100) substrates, the Bragg peak in the films is located at the depth where it would be found in Si rather than in LiF due to multiple Coulomb scattering. In this paper, Monte Carlo simulations of proton irradiations in the 1–8 MeV energy range are performed and compared to experimental Bragg curves in optically transparent LiF films on Si(100) substrates. Our study focuses on this energy range because, as energy increases, the Bragg peak gradually shifts from the depth in LiF to that in Si. The impact of grazing incidence angle, LiF packing density, and film thickness on shaping the Bragg curve in the film is examined. At energies higher than 8 MeV, all these quantities must be considered, although the effect of packing density plays a minor role.
1 November 2021 in Review of Scientific Instruments
In a medical accelerator, real-time monitoring systems of the beam and dose delivered to the patient are mandatory. In this work, we present a compact current profile detector that has been designed and tested in the framework of the TOP-IMPLART (Intensity Modulated Proton Linear Accelerator for RadioTerapy) project. This project foresees the realization of a proton linear accelerator, currently under construction at ENEA Frascati, for proton therapy applications. The linac produces a pulsed proton beam with 3 µs duration at 50 Hz repetition rate with a pulse current between 0.5 and 50 μA. A large dynamic range and spatial constraints make the use of usual noninterceptive beam diagnostics unfeasible. Therefore, the use of a beam current monitor based on a passive RF cavity working in the TM010 mode has been proposed. This paper reports the electromagnetic design of the device guided by a simplified analytical model. A prototype of such a device has been realized, characterized, and tested on the linac with a 35 MeV beam varying the beam current. The test results in air and in vacuum, together with the signal detection systems used, are presented.
Protons are now increasingly used to treat pediatric medulloblastoma (MB) patients. We designed and characterized a setup to deliver proton beams for in vivo radiobiology experiments at a TOP-IMPLART facility, a prototype of a proton-therapy linear accelerator developed at the ENEA Frascati Research Center, with the goal of assessing the feasibility of TOP-IMPLART for small animal proton therapy research. Mice bearing Sonic-Hedgehog (Shh)-dependent MB in the flank were irradiated with protons to test whether irradiation could be restricted to a specific depth in the tumor tissue and to compare apoptosis induced by the same dose of protons or photons. In addition, the brains of neonatal mice at postnatal day 5 (P5), representing a very small target, were irradiated with 6 Gy of protons with two different collimated Spread-Out Bragg Peaks (SOBPs). Apoptosis was visualized by immunohistochemistry for the apoptotic marker caspase-3-activated, and quantified by Western blot. Our findings proved that protons could be delivered to the upper part while sparing the deepest part of MB. In addition, a comparison of the effectiveness of protons and photons revealed a very similar increase in the expression of cleaved caspase-3. Finally, by using a very small target, the brain of P5-neonatal mice, we demonstrated that the proton irradiation field reached the desired depth in brain tissue. Using the TOP-IMPLART accelerator we established setup and procedures for proton irradiation, suitable for translational preclinical studies. This is the first example of in vivo experiments performed with a “full-linac” proton-therapy accelerator.
14 January 2025 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
In certain experimental setups used for proton irradiations at the TOP-IMPLART linear accelerator at the ENEA Frascati Center, the energy spectrum of the proton beam is measured at the end of a propagation path, which includes transmission through different materials, such as air, windows, slabs, etc. In this paper, we develop and test an approximate mathematical method to calculate the energy spectrum at the accelerator exit from such a measured transmitted spectrum. In the first experimental test application, the spectrum measurement exploits the visible photoluminescence of F2 and F3+ color centers generated in lithium fluoride crystals by the interaction of the crystal lattice with protons. In the second test application, a simulated measurement of a propagated energy spectrum along a transport line is considered. In principle, the proposed method is applicable to the energy spectra of proton beams measured in any manner.