Zhen Fang

Dr. Zhen Fang


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2026 in Tsinghua Science and Technology
Verified
Journal Article
Open access
PDF file
YYYicheng Yao
Yicheng Yao
PWPeng Wang
Peng Wang
ZBZhongrui Bai
Zhongrui Bai
ZHZhang Hao
Zhang Hao
PXPan Xia
Pan Xia
ZFZhen Fang
Zhen Fang
Detecting and treating older adults who fall in an environment without others is essential. Millimeter-wave radar sensors do not have the disadvantage of invading user privacy like cameras, nor do they require users to wear them in real-time like wearable devices. Actual samples of older adults fall are difficult to collect, and it is unethical to require older adults to fall repeatedly to collect data. In addition, different body types and action patterns will inevitably reduce the model’s performance when new users use the model. In this paper, we constructed a fall detection model based on anomaly detection. The model is trained only using non-fall samples and detects falls as abnormal actions. The proposed model uses a domain generalization architecture based on domain feature alignment to extract domain-invariant features of the model, thereby improving the model’s generalization ability. In addition, we introduced the idea of denoising learning into the feature extractor and feature predictor to improve the model’s anti-interference ability. We conducted sufficient experiments to explore the effectiveness of the proposed method. When tested with new domain data, the proposed model has a true positive rate of 96.12%, a false positive rate of 0.97%, and an area under the receiver operating characteristic of 0.9979.

2 December 2024 in Bioengineering
Verified
Journal Article
Open access
PDF file
ZBZhongrui Bai
Zhongrui Bai
PWPang Wu
Pang Wu
FGFanglin Geng
Fanglin Geng
ZHZhang Hao
Zhang Hao
XCXianxiang Chen
Xianxiang Chen
YWYirong Wu
Yirong Wu
Heartbeat inter-beat interval (IBI) extraction is a crucial technology for unobtrusive vital sign monitoring, yet its precision and robustness remain challenging. A promising approach is fusing heartbeat signals from different types of unobtrusive sensors. This paper introduces HSF-IBI, a novel and universal framework for unobtrusive IBI extraction using heterogeneous sensor fusion. Specifically, harmonic summation (HarSum) is employed for calculating the average heart rate, which in turn guides the selection of the optimal band selection (OBS), the basic sequential algorithmic scheme (BSAS)-based template group extraction, and the template matching (TM) procedure. The optimal IBIs are determined by evaluating the signal quality index (SQI) for each heartbeat. The algorithm is morphology-independent and can be adapted to different sensors. The proposed algorithm framework is evaluated on a self-collected dataset including 19 healthy participants and an open-source dataset including 34 healthy participants, both containing heterogeneous sensors. The experimental results demonstrate that (1) the proposed framework successfully integrates data from heterogeneous sensors, leading to detection rate enhancements of 6.25 % and 5.21 % on two datasets, and (2) the proposed framework achieves superior accuracy over existing IBI extraction methods, with mean absolute errors (MAEs) of 5.25 ms and 4.56 ms on two datasets.

29 May 2023 in arXiv
Verified
Preprint
Open access
PDF file
Lirui XuLirui Xu
Lirui Xu
PWPang Wu
Pang Wu
PXPan Xia
Pan Xia
FGFanglin Geng
Fanglin Geng
PWPeng Wang
Peng Wang
ZFZhen Fang
Zhen Fang
The local beat-to-beat local pulse pressure (PP) and blood pressure waveform of arteries, especially central arteries, are important indicators of the course of cardiovascular diseases (CVDs). Nevertheless, noninvasive measurement of them remains a challenge in the clinic. This work presents a three-element image-free ultrasound system with a low-computational method for real-time measurement of local pulse wave velocity (PWV) and diameter waveforms, enabling real-time and noninvasive continuous PP and blood pressure waveforms measurement without calibration. The developed system has been well-validated in vitro and in vivo. In in vitro cardiovascular phantom experiments, the results demonstrated high accuracy in the measurement of PP (error < 3 mmHg) and blood pressure waveform (root-mean-square-errors (RMSE) < 2 mmHg, correlation coefficient (r) > textgreater 0.99). In subsequent human carotid experiments, the system was compared with an arterial tonometer, which showed excellent PP accuracy (mean absolute error (MAE) = 3.7 +- 3.4 mmHg) and pressure waveform similarity (RMSE = 3.7 +- 1.6 mmHg, r = 0.98 +- 0.01). Furthermore, comparative experiments with the volume clamp device demonstrated the system's ability to accurately trace blood pressure changes (induced by deep breathing) over a period of one minute, with the MAE of DBP, MAP, and SBP within 5 +- 8 mmHg. The present results demonstrate the accuracy and reliability of the developed system for continuous and noninvasive measurement of arterial PP and blood pressure waveform measurements, with potential applications in the diagnosis and prevention of CVDs.