The aim of this work was to analyze and compare the tooth structure removal between a free-hand preparation technique and a computer-aided preparation technique using an augmented reality appliance for complete-crowns preparation designs and “root mean square” (RMS) alignment value. Ten upper teeth representatives of all dental sectors were selected from a generic model library as “Standard Tessellation Language” (STL-1) digital files and 3D-printed in an anatomically based acrylic resin experimental model. Then these were randomly assigned to the following tooth preparation techniques: Group A: free-hand preparation technique (n = 5) (FHT) and Group B: computer-aided preparation technique using an augmented reality appliance (n = 5) (AR). Experimental models were submitted to a digital impression through an intraoral scan and (STL-2) uploaded into a reverse engineering morphometric software to measure the volumetric reduction in the planned and performed tooth structure (mm3) and RMS using the Student’s t-test and the Mann–Whitney non-parametric test. Statistically significant differences were observed between the volumetric reduction in the planned and performed tooth structure (mm3) of the AR and FHT study groups (p = 0.0001). Moreover, statistically significant differences were observed between the RMS of the planned and performed tooth preparations in both the AR and FHT study groups (p = 0.0005). The augmented reality appliance provides a more conservative and predictable complete-crowns preparation design than the free-hand preparation technique.
Purpose: The aim was to analyze the accuracy of digital models and 3D-printed casts from full-arch digital impressions using two intraoral scanners (iTeroTM and PrimescanTM). Materials and methods: A crossover reliability study was designed, scanning children and teenagers with iTeroTM and PrimescanTM. Accuracy was evaluated by measuring intercanine, intermolar, and ipsilateral canine–molar distances intraorally and comparing these measurements with those from plaster casts, digital models obtained with intraoral scanners, and 3D-printed casts. A paired comparison and a general linear model with a one-way repeated measures ANOVA procedure were carried out with a confidence level of 95% (p ≤ 0.05). Results: A total of 51 subjects were analyzed (mean age 12.35 ± 2.57). Statistical differences (p < 0.05) were found in the upper and lower arch regarding accuracy in comparison to intraoral measurements, except for the iTeroTM-printed cast and canine–molar upper right and intercanine lower distances (p > 0.05 for all comparisons). Regarding a comparison between reproduction methods, the plaster cast oversized the intercanine upper distance in comparison with both intraoral scanners’ digital models and the PrimescanTM-printed cast (p = 0.001), but there were no differences in the lower arch (p > 0.05 for all comparisons). Conclusion: Intraoral scanners reproduce tooth structures with similar accuracy to conventional methods.
An inaccurate bonding procedure of the attachments related to clear aligner systems could influence the predictability of tooth movement The aim of this study was to compare the positioning reliability of horizontal and vertical orthodontic clear aligner attachments. Materials and Methods: A total of 70 horizontal and 70 vertical orthodontic clear aligner attachments were bonded to five upper and five lower experimental anatomically based acrylic resin models with 14 clinical crowns each. The experimental anatomically based acrylic resin models were randomly distributed to the following study groups: Group A—horizontal orthodontic clear aligner attachments (n = 70) (HORIZONTAL) and Group B—vertical orthodontic clear aligner attachments (n = 70) (VERTICAL). Afterward, the orthodontic clear aligner attachments were digitally planned using orthodontic planning software, and orthodontic templates were manufactured by thermoforming on 3D-printed models in trilayer glycol-modified polyethylene terephthalate. Both horizontal and vertical orthodontic clear aligner attachments were put through an intra-oral scan to obtain a postoperative digital image, and PAPver, PCPver, PMVver, AUver, Alver, PPMhor, PPDhor, PMVhor, AMhor and ADhor cephalometric parameters were analyzed using a t-test or a non-parametric Mann–Whitney–Wilcoxon test. Results: The results showed that all cephalometric parameters showed statistically significant differences (p < 0.05) between the accuracy of the indirect bonding technique for horizontal and vertical orthodontic clear aligner attachments, except for the PAPver (p = 0.6079) and PMVhor (p = 0.5001) cephalometric parameters. Conclusions: The vertical orthodontic clear aligner attachments are more accurate than the horizontal orthodontic clear aligner attachments through the indirect bonding technique.
The objective of the present study was to evaluate and compare the accuracy of the computer-aided static navigation technique (NAV), augmented reality (AR) and freehand placement technique (FHT) for the bicortical orthodontic self-drilling mini-implants for maxillary skeletal expansion (MSE) appliances placed in palate. Material and Methods: A total of 120 bicortical orthodontic self-drilling mini-implants were placed in the palate of ten 3D printed anatomically based polyurethane models of a completely edentulous upper maxilla. The orthodontic mini-implants were randomly assigned to the following placement techniques: (A) computer-aided static navigation technique (n = 40) (NAV), (B) augmented reality device (n = 40) (AR) and (C) conventional freehand technique (n = 40) (FHT). Moreover, two implants were placed in each side of the midpalatal suture in every model according to the digital planification of the expander device. Subsequently, the orthodontic mini-implants were placed and postoperative CBCT scans were performed. Finally, coronal entry-point (mm), apical end-point (mm) and angular deviations (°) were calculated using a t-test. Results: Statistically significant differences were shown at coronal entry-point (p < 0.001), apical end-point (p < 0.001) and angular deviations (p < 0.001) between the three placement techniques of bicortical orthodontic mini-implants. Additionally, statistically significant differences were also shown between the orthodontic mini-implant positions concerning the entry point (p = 0.004) and angular deviation (p = 0.004). Conclusions: The augmented reality placement technique results are more accurate, followed by the computer-aided static navigation technique and the freehand technique for MSE appliances placed in palate.