The aim of this systematic review and meta-analysis was to analyze whether or not mandibular advancement devices (MADs) produce changes in blood pressure in patients with obstructive sleep apnea (OSA) in relation to use time and if the device is used at night or day. Materials and method: A systematic review of the literature and meta-analysis was carried out in accordance with PRISMA guidelines. In the bibliographic search, a total of four databases were consulted: PubMed-Medline, Scopus, Web of Science, and Cochrane. Of the 622 articles initially revealed, 160 duplicates were eliminated. After applying the selection criteria, 17 articles were included for the qualitative analysis and 4 for the meta-analysis. The studies were combined using a random effects model with the inverse method of variance, determining the mean differences in systolic and diastolic pressure before and after treatment using the MAD splint as the effect size. Day/night circadian effect and treatment time were analyzed using meta-regression with a mixed-effects model. Results: MAD treatment was not found to affect diastolic pressure. By combining the four studies with the control group in a meta-analysis (I2 = 75%; z = − 0.15; p-value = 0.882), the mean difference in diastolic pressure between the MAD group and the control group was estimated at − 0.06 (− 0.86; 0.74). The meta-regression also showed no significant effect of day/night (p = 0.560) or treatment time (p = 0.854) on diastolic pressure. When combining the four studies with the control group (I2 = 84%%; z = − 1.47; p-value = 0.142), a non-significant mean difference in systolic pressure between the MAD group and the control group of − 0.99 (− 2.31; 0.33) was estimated in the meta-analysis. However, when assessing the effect of day/night or treatment time on systolic blood pressure using a meta-regression, the latter showed significant covariates that reduce systolic blood pressure values in the model at night (p < 0.001) and in relation to treatment time (p < 0.001). Conclusions: Only systolic pressure appears to be affected by the use of the MAD in patients with OSA, and this decrease in systolic pressure is greater at night and when treatment time is longer.
The aim of this systematic review and meta-analysis was to analyze the association between periodontal disease and prostate inflammation with a null hypothesis stating that periodontal disease does not increase the incidence of prostate inflammation. Materials and methods: A systematic literature review and meta-analysis of longitudinal observational cohort and case-control studies that evaluated the odds ratio or hazard ratio and confidence interval was undertaken based on the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) recommendations (2020). A total of four databases were consulted in the literature search: PubMed-Medline, Scopus, Embase, and Web of Science. After eliminating duplicated articles and applying the inclusion criteria, seven articles were selected for the qualitative and quantitative analyses. Results: Four observational cohort studies and three observational cohort case-control studies were included in the meta-analysis. The four observational cohort studies were combined using the random effects model to estimate a hazard ratio of 1.32 with a confidence interval of 95% between 0.87 and 1.77. The meta-analysis presented high heterogeneity (Q test = 56.1; p value < 0.001; I2 = 94.9%). Moreover, the three observational case-control studies were combined using the random effects model to estimate an odds ratio of 1.62 with a confidence interval of 95% between 1.41 and 1.84. The meta-analysis presented high heterogeneity (Q test = 1.07; p value = 0.782; I2 = 0%). Conclusions: The incidence of periodontal disease does not increase the risk of the incidence of prostate inflammation.
An inaccurate bonding procedure of the attachments related to clear aligner systems could influence the predictability of tooth movement The aim of this study was to compare the positioning reliability of horizontal and vertical orthodontic clear aligner attachments. Materials and Methods: A total of 70 horizontal and 70 vertical orthodontic clear aligner attachments were bonded to five upper and five lower experimental anatomically based acrylic resin models with 14 clinical crowns each. The experimental anatomically based acrylic resin models were randomly distributed to the following study groups: Group A—horizontal orthodontic clear aligner attachments (n = 70) (HORIZONTAL) and Group B—vertical orthodontic clear aligner attachments (n = 70) (VERTICAL). Afterward, the orthodontic clear aligner attachments were digitally planned using orthodontic planning software, and orthodontic templates were manufactured by thermoforming on 3D-printed models in trilayer glycol-modified polyethylene terephthalate. Both horizontal and vertical orthodontic clear aligner attachments were put through an intra-oral scan to obtain a postoperative digital image, and PAPver, PCPver, PMVver, AUver, Alver, PPMhor, PPDhor, PMVhor, AMhor and ADhor cephalometric parameters were analyzed using a t-test or a non-parametric Mann–Whitney–Wilcoxon test. Results: The results showed that all cephalometric parameters showed statistically significant differences (p < 0.05) between the accuracy of the indirect bonding technique for horizontal and vertical orthodontic clear aligner attachments, except for the PAPver (p = 0.6079) and PMVhor (p = 0.5001) cephalometric parameters. Conclusions: The vertical orthodontic clear aligner attachments are more accurate than the horizontal orthodontic clear aligner attachments through the indirect bonding technique.
This study aimed to evaluate the retrievability and potential damage to implant–abutment connections caused by fractured abutment screw removal using conventional and drilling techniques. A total of forty abutment screws were randomly inserted into forty dental implants, and then they were fractured and extracted using different removal methods: Group A employed a conventional approach utilizing an exploration probe and an ultrasonic device without irrigation (n = 10) (conventional); Group B used the Phibo drilling removal system without irrigation (n = 10) (Phibo); Group C utilized the Rhein83® drilling removal system without irrigation (n = 10) (Rhein83); and Group D implemented the Sanhigia® drilling removal system without irrigation (n = 10) (Sanhigia). Pre- and postoperative micro-computed tomography (micro-CT) scans were performed on the dental implants, and Standard Tessellation Language (STL) digital files were generated for morphometric analysis to measure the wear volume. ANOVA was used to assess the volumetric differences (mm3) and percentage ratios of the internal thread volumes of the implant–abutment connections before and after the procedures. Results: This study found no statistically significant differences in the volumetric and percentage ratios of internal threads among the implant groups (Phibo, Rhein83, Sanhigia, and conventional). However, the success rate for retrieving fractured abutment screws was higher (90%) with the drilling systems compared to the conventional technique (50%). These results suggest that drilling systems are more effective for the retrieval of damaged screws. Although drilling techniques without irrigation demonstrated higher removal efficiency compared to the conventional method, both approaches resulted in similar wear volumes at the implant–abutment connections when used to extract fractured screws.
The pontic design may influence the load-to-failure performance of fixed implant-supported screw-retained monolithic zirconia prostheses. This study aimed to evaluate the effect of pontic geometry on the fracture resistance of such restorations. Forty restorations were designed using dental CAD software and divided into four groups (n = 10 each): (A) Flat + Wide—pontics with a flat contour, 10 mm in width and 8 mm in height; (B) Concave + Wide—pontics with a concave contour, 10 mm in width and 5.5 mm in height; (C) Flat + Narrow—pontics with a flat contour, 6 mm in width and 8 mm in height; and (D) Concave + Narrow—pontics with a concave contour, 6 mm in width and 5.5 mm in height. All specimens underwent thermal and mechanical cycling, followed by a fracture load test using a three-point bending setup. Maximum fracture loads and displacements were analyzed using one-way ANOVA. Statistically significant differences were observed among the groups for both load to failure (p = 0.001) and displacement (p = 0.002). These findings indicate that pontic geometry significantly influences the fracture resistance and deformation behavior of monolithic zirconia prostheses.