Silica nanoparticles (SiNPs) are being studied and used for medical purposes. As nanotechnology grows rapidly, its biosafety and toxicity have frequently raised concerns. However, diverse results have been reported about the safety of SiNPs; several studies reported that smaller particles might exhibit toxic effects to some cell lines, and larger particles of 100 nm were reported to be genotoxic to the cocultured cells. Here, we investigated the in vivo toxicity of SiNPs of 150 nm in various dosages via intravenous administration in mice. The mice were observed for 14 days before blood examination and histopathological assay. All the mice survived and behaved normally after the administration of nanoparticles. No significant weight change was noted. Blood examinations showed no definite systemic dysfunction of organ systems. Histopathological studies of vital organs confirmed no SiNP-related adverse effects. We concluded that 150 nm SiNPs were biocompatible and safe for in vivo use in mice.
Articular cartilage defects affect millions of people worldwide, including children, adolescents, and adults. Progressive wear and tear of articular cartilage can lead to progressive tissue loss, further exposing the bony ends and leaving them unprotected, which may ultimately cause osteoarthritis (degenerative joint disease). Unlike other self-repairing tissues, cartilage has a low regenerative capacity; once injured, the cartilage is much more difficult to heal. Consequently, developing methods to repair this defect remains a challenge in clinical practice. In recent years, tissue engineering applications have employed the use of three-dimensional (3D) porous scaffolds for growing cells to regenerate damaged cartilage. However, these scaffolds are mainly chemically synthesized polymers or are crosslinked using organic solvents. Utilizing 3D printing technologies to prepare biodegradable natural composite scaffolds could replace chemically synthesized polymers with more natural polymers or low-toxicity crosslinkers. In this study, collagen/oligomeric proanthocyanidin/oxidized hyaluronic acid composite scaffolds showing high biocompatibility and excellent mechanical properties were prepared. The compressive strengths of the scaffolds were between 0.25–0.55 MPa. Cell viability of the 3D scaffolds reached up to 90%, which indicates that they are favorable surfaces for the deposition of apatite. An in vivo test was performed using the Sprague Dawley (SD) rat skull model. Histological images revealed signs of angiogenesis and new bone formation. Therefore, 3D collagen-based scaffolds can be used as potential candidates for articular cartilage repair.
1 September 2008 in Korean Journal of Chemical Engineering
A rapid identification of Salmonella, one of the most common foodborne pathogens worldwide, in clinical patients can enable better rational managements and prevent further outbreaks. The traditional immunochromatography using antibody–gold nanoparticles (Ab‐AuNPs), such as the home pregnancy test, has been used for the Salmonella detection. In this study, we developed a new and rapid method using DNA probe‐AuNPs for the detection of 16s ribosomal DNA of Salmonella. To evaluate the proposed method in clinical specimens, we performed a clinical test by identifying 159 stool samples on Hektoen agar containing black or crystalloid colonies using the method and the VITEK 2 system for confirmation. Eighty of the isolates were correctly identified as Salmonella to achieve 100% sensitivity. Seventy‐five samples were correctly identified as non‐Salmonella spp., but four were incorrectly identified as Salmonella. The specificity was 94·93%. The assay time is about 30 min after the DNA purification. The time‐consuming and labour‐intense biochemical tests can be replaced. We demonstrated that this assay is a rapid, convenient and cost‐effective tool for Salmonella identification of clinical faecal samples, which is worth for further promotion and clinical use. This is the first application of using 16s ribosomal DNA probe‐Au‐NPs and immunochromatography on clinical samples. Significance and Impact of the Study This is the first application of using 16s ribosomal DNA probe–gold nanoparticles and immunochromatography method on clinical samples with sensitivity 100% and specificity 94·93%. The assay time is about 30 min after the DNA purification. We find this assay a rapid, convenient, sensitive and inexpensive tool for Salmonella identification of clinical faecal samples, which is worth further promotion and clinical use and can replace the traditional time‐consuming and labour‐intense biochemical tests. The potential benefit of this approach is to develop a rapid point‐of‐care test that provides results while the patient is still at the doctors' office.
19 February 2008 in Journal of Applied Polymer Science