Several models were successfully developed to reproduce the dynamic behavior of ZnO surge arrester, but the accuracy and reliability of these models are only evaluated for residual voltage calculations. This paper presents a model developed with the specific goal of achieving reliable and accurate modeling of the energy absorbed by a ZnO surge arrester during impulsive transients. To develop and test the model, an experimental database was built, composed of responses of ZnO varistors to current impulses. The database contains the response of varistors of different classes and manufacturers, subjected to current impulses with different waveforms and amplitudes. Then, using system identification techniques, a mathematical model was proposed and validated. The proposed model was successfully tested on the same circumstances that traditional models are used and its performance was compared with the most relevant existing ZnO model. The results indicate that the developed model is an overall valid model for ZnO surge arresters and that energy calculations performed with it are more accurate and reliable.
This work proposes a methodology for noise removal, separation, and classification of partial discharges in electrical system assets. Partial discharge analysis is an essential method for fault detection and evaluation of the operational conditions of high-voltage equipment. However, it faces several limitations in field measurements due to interference from radio signals, television transmissions, WiFi, corona signals, and multiple sources of partial discharges. To address these challenges, we propose the development of a clustering model to identify partial discharge sources and a classification model to identify the types of discharges. New features extracted from pulses are introduced to model the clustering and classification of discharge sources. The methodology is tested in the laboratory with controlled partial discharge sources, and field tests are conducted in substations to assess its practical applicability. The results of laboratory tests achieved an accuracy of 85% in classifying discharge sources. Field tests were performed in a substation of the Eletrobras group, allowing the identification of at least three potentially defective current transformers.
This paper introduces a novel approach for diagnosing failures within a turbogenerator mineral lube oil system, employing a fuzzy inference system (FIS) model. The study leverages real operational data collected from supervisory monitoring sensors across four turbogenerators over a three-year operational span, resulting in a dataset comprising 40,456,663 input parameters. The failure modes were established through expert knowledge, using the Failure Mode, Effect, and Criticality Analysis (FMECA) documentation as the basis. Initially, the model’s universe variables were constructed using the sensor calibration range, and then the fuzzy membership functions were formulated based on the operational thresholds inherent to each measured parameter. The fault identification mechanism is underpinned by an inference system employing predefined rules, extrapolated from expert judgments encapsulating failure typologies specific to the turbogenerators’ mineral lube oil system, as delineated in the FMECA. The FIS model demonstrates notable efficacy in failure diagnosis with an overall performance evaluation of the system yielding satisfactory outcomes, having a 98.35% true positive rate for failure classification, coupled with a 99.99% true negative rate for accurate classification during normal system operation. These results highlight the visibility of the FIS model in diagnosing failures within the turbogenerator mineral lube oil system, thereby showcasing its potential for enhancing operational reliability and maintenance efficiency.