João Victor Jales de Melo

Ms. João Victor Jales de Melo

Federal University of Campina Grande, Campina Grande, Paraíba, Brazil
orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 August 2024 in Energies
Verified
Journal Article
Open access
PDF file
João Victor Jales de MeloJoão Victor Jales de Melo
João Victor Jales de Melo
GLGeorge Lira
George Lira
ECEdson Guedes Da Costa
Edson Guedes Da Costa
PVPablo Vilar
Pablo Vilar
FAFilipe Lucena Medeiros de Andrade
Filipe Lucena Medeiros de Andrade
AJAlmir Carlos dos Santos Júnior
Almir Carlos dos Santos Júnior
This work proposes a methodology for noise removal, separation, and classification of partial discharges in electrical system assets. Partial discharge analysis is an essential method for fault detection and evaluation of the operational conditions of high-voltage equipment. However, it faces several limitations in field measurements due to interference from radio signals, television transmissions, WiFi, corona signals, and multiple sources of partial discharges. To address these challenges, we propose the development of a clustering model to identify partial discharge sources and a classification model to identify the types of discharges. New features extracted from pulses are introduced to model the clustering and classification of discharge sources. The methodology is tested in the laboratory with controlled partial discharge sources, and field tests are conducted in substations to assess its practical applicability. The results of laboratory tests achieved an accuracy of 85% in classifying discharge sources. Field tests were performed in a substation of the Eletrobras group, allowing the identification of at least three potentially defective current transformers.

12 August 2022 in Energies
Verified
Journal Article
Open access
PDF file
João Victor Jales de MeloJoão Victor Jales de Melo
João Victor Jales de Melo
GLGeorge Lira
George Lira
ECEdson Guedes Da Costa
Edson Guedes Da Costa
ANAntonio Francisco Leite Neto
Antonio Francisco Leite Neto
Iago Batista OliveiraIago Batista Oliveira
Iago Batista Oliveira
Maintaining stability and control over the electric system requires increasing information about the consumers’ profiling due to changes in the form of electricity generation and consumption. To overcome this trouble, short-term load forecasting (STLF) on individual consumers gained importance in the last years. Nonetheless, predicting the profile of an individual consumer is a difficult task. The main challenge lies in the uncertainty related to the individual consumption profile, which increases forecasting errors. Thus, this paper aims to implement a load predictive model focused on individual consumers taking into account its randomness. For this purpose, a methodology is proposed to determine and select predictive features for individual STLF. The load forecasting of an individual consumer is simulated based on the four main machine learning techniques used in the literature. A 2.73% reduction in the forecast error is obtained after the correct selection of the predictive features. Compared to the baseline model (persistent forecasting method), the error is reduced by up to 19.8%. Among the techniques analyzed, support vector regression (SVR) showed the smallest errors (8.88% and 9.31%).

15 October 2025
Verified
Book Chapter
Open access
PDF file
ANAntonio Francisco Leite Neto
Antonio Francisco Leite Neto
ECEdson Guedes Da Costa
Edson Guedes Da Costa
BDBruno Albuquerque Dias
Bruno Albuquerque Dias
João Victor Jales de MeloJoão Victor Jales de Melo
João Victor Jales de Melo
This paper presents a study of the electric field in pin type insulators under the influence of an internal cavity. Polymeric insulators 15 kV were modeled with the aid of technical design software. Computational simulations to obtain the electric field were performed using COMSOL Multiphysics. The simulated cavity inside the insulator has spherical and elliptical geometry, with different values for its diameter. The position of the internal defect was varied from a region near the cable to a region near the hardware. For each simulated case, three levels of pollution were applied to the surface of the insulator, also considering the case in which it is intact. The results obtained for the case in which the insulator is intact does not present large variations in the electric field in the internal region. With the presence of a cavity, the electric field distortions in the cavity region assumed high values, surpassing in some cases the value of the dielectric strength of atmospheric air. The most critical defect detected was for elliptical geometry, whose electric field values were higher than the spherical case.

1 January 2026 in IEEE Access
Verified
Journal Article
Open access
ANAntonio Francisco Leite Neto
Antonio Francisco Leite Neto
PVPablo Vilar
Pablo Vilar
ECEdson Guedes Da Costa
Edson Guedes Da Costa
JAJalberth F. De Araujo
Jalberth F. De Araujo
ASAylla E. D. Santos
Aylla E. D. Santos
João Victor Jales de MeloJoão Victor Jales de Melo
João Victor Jales de Melo

1 January 2026 in IEEE Access
Verified
Journal Article
Open access
João Victor Jales de MeloJoão Victor Jales de Melo
João Victor Jales de Melo
GLGeorge Lira
George Lira
ECEdson Guedes Da Costa
Edson Guedes Da Costa
PVPablo Vilar
Pablo Vilar
ANAntonio Francisco Leite Neto
Antonio Francisco Leite Neto
FMFernando Do Nascimento Madia
Fernando Do Nascimento Madia

31 July 2026 in Energies
Verified
Journal Article
Open access
PDF file
Igor Monteiro SantosIgor Monteiro Santos
Igor Monteiro Santos
PVPablo Vilar
Pablo Vilar
BVBreno A. Vieira
Breno A. Vieira
João Victor Jales de MeloJoão Victor Jales de Melo
João Victor Jales de Melo
GGGiovanny Marcellus Marcellus Borges Borges Galdino
Giovanny Marcellus Marcellus Borges Borges Galdino
MMMaycon R. Macedo
Maycon R. Macedo
This paper proposes an integrated framework for predictive asset management in electric power distribution systems by combining machine learning with the Analytic Hierarchy Process (AHP). Distinct utility datasets were used according to the characteristics of each prediction task. Annual preventive- and corrective-maintenance records, including maintenance cost and frequency, covered the period from 2016 to 2023, whereas the SAIDI and SAIFI annual time series covered the period from 2014 to 2023. Remaining Useful Life (RUL) estimation was based on static asset-level records from the entire available equipment stock and therefore was not associated with a single time-series interval. Multiple machine learning algorithms were evaluated independently for each Type of Utility Component (TUC), and the best-performing models were selected according to their validation errors. The resulting predictions were incorporated into a two-level AHP hierarchy that integrates technical, economic, operational, and regulatory criteria for portfolio-level asset-renewal prioritization. For RUL estimation, the selected TUC-specific models reduced the mean MAE from 11.33 years for the historical-mean baseline to 2.70 years, corresponding to an absolute improvement of 8.63 years and a relative reduction of 76.15%. The resulting priority ranking was evaluated retrospectively using moving-average, cumulative-gain, and lift analyses. The top 20% of ranked assets captured 29.61% of the observed corrective-maintenance occurrences, corresponding to a lift of 1.4806 relative to random selection. The cumulative-gain curve yielded an area under the curve of 0.6337 and a ranking Gini coefficient of 0.2674, indicating moderate positive discrimination across the asset portfolio. These results show that the proposed ML–AHP framework can support the allocation of inspection, engineering-assessment, and renewal resources toward assets with comparatively greater maintenance demand and operational relevance. The framework provides a structured, data-driven decision-support approach for utility asset-renewal planning, while prospective field implementation remains necessary to quantify reductions in failures, corrective maintenance, continuity penalties, and total expenditure.