Marco Pennazio

Marco Pennazio

orcid

Research Focus & Metrics

Academic Career Length

37Years (1990-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 November 2022 in Endoscopy
Verified
Journal Article
Closed access
PDF file
MPMarco Pennazio
Marco Pennazio
EREmanuele Rondonotti
Emanuele Rondonotti
EDEdward J. Despott
Edward J. Despott
XDXavier Dray
Xavier Dray
MKMartin Keuchel
Martin Keuchel
Konstantinos TriantafyllouKonstantinos Triantafyllou
Konstantinos Triantafyllou
Main Recommendations: MR1 ESGE recommends small-bowel capsule endoscopy as the first-line examination, before consideration of other endoscopic and radiological diagnostic tests for suspected small-bowel bleeding, given the excellent safety profile of capsule endoscopy, its patient tolerability, and its potential to visualize the entire small-bowel mucosa.Strong recommendation, moderate quality evidence. MR2 ESGE recommends small-bowel capsule endoscopy in patients with overt suspected small-bowel bleeding as soon as possible after the bleeding episode, ideally within 48 hours, to maximize the diagnostic and subsequent therapeutic yield.Strong recommendation, high quality evidence. MR3 ESGE does not recommend routine second-look endoscopy prior to small-bowel capsule endoscopy in patients with suspected small-bowel bleeding or iron-deficiency anemia.Strong recommendation, low quality evidence. MR4 ESGE recommends conservative management in those patients with suspected small-bowel bleeding and high quality negative small-bowel capsule endoscopy.Strong recommendation, moderate quality evidence. MR5 ESGE recommends device-assisted enteroscopy to confirm and possibly treat lesions identified by small-bowel capsule endoscopy.Strong recommendation, high quality evidence. MR6 ESGE recommends the performance of small-bowel capsule endoscopy as a first-line examination in patients with iron-deficiency anemia when small bowel evaluation is indicated.Strong recommendation, high quality evidence. MR7 ESGE recommends small-bowel capsule endoscopy in patients with suspected Crohn’s disease and negative ileocolonoscopy findings as the initial diagnostic modality for investigating the small bowel, in the absence of obstructive symptoms or known bowel stenosis.Strong recommendation, high quality evidence. MR8 ESGE recommends, in patients with unremarkable or nondiagnostic findings from dedicated small-bowel cross-sectional imaging, small-bowel capsule endoscopy as a subsequent investigation if deemed likely to influence patient management.Strong recommendation, low quality evidence. MR9 ESGE recommends, in patients with established Crohn’s disease, the use of a patency capsule before small-bowel capsule endoscopy to decrease the capsule retention rate.Strong recommendation, moderate quality evidence. MR10 ESGE recommends device-assisted enteroscopy (DAE) as an alternative to surgery for foreign bodies retained in the small bowel requiring retrieval in patients without acute intestinal obstruction.Strong recommendation, moderate quality evidence. MR11 ESGE recommends DAE-endoscopic retrograde cholangiopancreatography (DAE-ERCP) as a first-line endoscopic approach to treat pancreaticobiliary diseases in patients with surgically altered anatomy (except for Billroth II patients).Strong recommendation, moderate quality evidence.

28 April 2022 in Diagnostics
Verified
Journal Article
Open access
PDF file
PVPablo Cortegoso Valdivia
Pablo Cortegoso Valdivia
Karolina Skonieczna-ŻydeckaKarolina Skonieczna-Żydecka
Karolina Skonieczna-Żydecka
AEAlfonso ELOSUA
Alfonso ELOSUA
MSMartina Sciberras
Martina Sciberras
SPStefania Piccirelli
Stefania Piccirelli
Anastasios KoulaouzidisAnastasios Koulaouzidis
Anastasios Koulaouzidis
Background: Capsule endoscopy (CE) has become a widespread modality for non-invasive evaluation of the gastrointestinal (GI) tract, with several CE models having been developed throughout the years. The aim of this systematic review and meta-analysis is to evaluate performance measures such as completion, detection and retention rates of CE. Methods: Literature through to August 2021 was screened for articles regarding all capsule types: small bowel, double-headed capsule for the colon or PillCam®Crohn’s capsule, magnetically-controlled capsule endoscopy, esophageal capsule and patency capsule. Primary outcomes included detection rate (DR), completion rate (CR) and capsule retention rate (RR). DR, CR and RR were also analyzed in relation to indications such as obscure GI bleeding (OGIB), known/suspected Crohn’s disease (CD), celiac disease (CeD), neoplastic lesions (NL) and clinical symptoms (CS). Results: 328 original articles involving 86,930 patients who underwent CE were included. OGIB was the most common indication (n = 44,750), followed by CS (n = 17,897), CD (n = 11,299), NL (n = 4989) and CeD (n = 947). The most used capsule type was small bowel CE in 236 studies. DR, CR and RR for all indications were 59%, 89.6% and 2%, respectively. According to specific indications: DR were 55%, 66%, 63%, 52% and 62%; CR were 90.6%, 86.5%, 78.2%, 94% and 92.8%; and RR were 2%, 4%, 1%, 6% and 2%. Conclusions: Pooled DR, CR and RR are acceptable for all capsule types. OGIB is the most common indication for CE. Technological advancements have expanded the scope of CE devices in detecting GI pathology with acceptable rates for a complete examination.

1 January 2008 in World Journal of Gastroenterology
Verified
Journal Article
Open access
MPMarco Pennazio
Marco Pennazio
EREmanuele Rondonotti
Emanuele Rondonotti
RFRoberto de Franchis
Roberto de Franchis
Capsule endoscopy in neoplastic diseases

20 September 2021 in Diagnostics
Verified
Journal Article
Open access
PDF file
UDUlrik Deding
Ulrik Deding
PVPablo Cortegoso Valdivia
Pablo Cortegoso Valdivia
Anastasios KoulaouzidisAnastasios Koulaouzidis
Anastasios Koulaouzidis
GBgunnar baatrup
gunnar baatrup
Ervin TothErvin Toth
Ervin Toth
TBThomas Bjørsum-Meyer
Thomas Bjørsum-Meyer
Colon capsule endoscopy as an alternative to colonoscopy for the diagnosis of colonic disease may serve as a less invasive and more tolerable investigation for patients. Our aim was to examine patient-reported outcomes for colon capsule endoscopy compared to conventional optical colonoscopy including preference of investigation modality, tolerability and adverse events. A systematic literature search was conducted in Web of Science, PubMed and Embase. Search results were thoroughly screened for in- and exclusion criteria. Included studies underwent assessment of transparency and completeness, after which, data for meta-analysis were extracted. Pooled estimates of patient preference were calculated and heterogeneity was examined including univariate meta-regressions. Patient-reported tolerability and adverse events were reviewed. Out of fourteen included studies, twelve had investigated patient-reported outcomes in patients who had undergone both investigations, whereas in two the patients were randomized between investigations. Pooled patient preferences were estimated to be 52% (CI 95%: 41–63%) for colon capsule endoscopy and 45% (CI 95%: 33–57%) for conventional colonoscopy: not indicating a significant difference. Procedural adverse events were rarely reported by patients for either investigation. The tolerability was high for both colon capsule endoscopy and conventional colonoscopy. Patient preferences for conventional colonoscopy and colon capsule endoscopy were not significantly different. Procedural adverse events were rare and the tolerability for colon capsule endoscopy was consistently reported higher or equal to that of conventional colonoscopy.

2 October 2022 in Diagnostics
Verified
Journal Article
Open access
PDF file
PVPablo Cortegoso Valdivia
Pablo Cortegoso Valdivia
UDUlrik Deding
Ulrik Deding
TBThomas Bjørsum-Meyer
Thomas Bjørsum-Meyer
GBgunnar baatrup
gunnar baatrup
IFIgnacio Fernández-Urién
Ignacio Fernández-Urién
Anastasios KoulaouzidisAnastasios Koulaouzidis
Anastasios Koulaouzidis
Video-capsule endoscopy (VCE) reading is a time- and energy-consuming task. Agreement on findings between readers (either different or the same) is a crucial point for increasing performance and providing valid reports. The aim of this systematic review with meta-analysis is to provide an evaluation of inter/intra-observer agreement in VCE reading. A systematic literature search in PubMed, Embase and Web of Science was performed throughout September 2022. The degree of observer agreement, expressed with different test statistics, was extracted. As different statistics are not directly comparable, our analyses were stratified by type of test statistics, dividing them in groups of “None/Poor/Minimal”, “Moderate/Weak/Fair”, “Good/Excellent/Strong” and “Perfect/Almost perfect” to report the proportions of each. In total, 60 studies were included in the analysis, with a total of 579 comparisons. The quality of included studies, assessed with the MINORS score, was sufficient in 52/60 studies. The most common test statistics were the Kappa statistics for categorical outcomes (424 comparisons) and the intra-class correlation coefficient (ICC) for continuous outcomes (73 comparisons). In the overall comparison of inter-observer agreement, only 23% were evaluated as “good” or “perfect”; for intra-observer agreement, this was the case in 36%. Sources of heterogeneity (high, I2 81.8–98.1%) were investigated with meta-regressions, showing a possible role of country, capsule type and year of publication in Kappa inter-observer agreement. VCE reading suffers from substantial heterogeneity and sub-optimal agreement in both inter- and intra-observer evaluation. Artificial-intelligence-based tools and the adoption of a unified terminology may progressively enhance levels of agreement in VCE reading.

1 July 2019 in Digestive and Liver Disease
Verified
Journal Article
Closed access
MPMarco Pennazio
Marco Pennazio
LVLudovica Venezia
Ludovica Venezia
PVPablo Cortegoso Valdivia
Pablo Cortegoso Valdivia
EREmanuele Rondonotti
Emanuele Rondonotti