Abbas Javed

Dr. Abbas Javed

orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 August 2016 in IEEE Transactions on Industrial Informatics
Verified
Journal Article
Closed access
AJAbbas Javed
Abbas Javed
Hadi LarijaniHadi Larijani
Hadi Larijani
AAAli Ahmadinia
Ali Ahmadinia
DGDesmond Gibson
Desmond Gibson
Smart homes reduce human intervention in controlling the heating ventilation and air conditioning (HVAC) systems for maintaining a comfortable indoor environment. The embedded intelligence in the sensor nodes is limited due to the limited processing power and memory in the sensor node. Cloud computing has become increasingly popular due to its capability of providing computer utilities as internet services. In this study, a model for the intelligent controller by integrating internet of things (IoT) with cloud computing and web services is proposed. The wireless sensor nodes for monitoring the indoor environment and HVAC inlet air, and wireless base station for controlling the actuators of HVAC have been developed. The sensor nodes and base station communicate through RF transceivers at 915 MHz. Random neural network (RNN) models are used for estimating the number of occupants, and for estimating the predicted-mean-vote-based setpoints for controlling the heating, ventilation, and cooling of the building. Three test cases are studied (Case 1-Data storage and implementation of RNN models on the cloud, Case 2-RNN models implementation on base station, Case 3-Distributed implementation of RNN models on sensor nodes and base stations) for determining the best architecture in terms of power consumption. The results have shown that by embedding the intelligence in the base station and sensor nodes (i.e., Case 3), the power consumption of the intelligent controller was 4.4% less than Case 1 and 19.23% less than Case 2.

9 December 2016 in ACM Transactions on Internet Technology
Verified
Journal Article
Open access
PDF file
ASAhmed Saeed
Ahmed Saeed
Ali AhmadiniaAli Ahmadinia
Ali Ahmadinia
AJAbbas Javed
Abbas Javed
HLHadi Larijani
Hadi Larijani
Security and privacy of data are one of the prime concerns in today’s Internet of Things (IoT). Conventional security techniques like signature-based detection of malware and regular updates of a signature database are not feasible solutions as they cannot secure such systems effectively, having limited resources. Programming languages permitting immediate memory accesses through pointers often result in applications having memory-related errors, which may lead to unpredictable failures and security vulnerabilities. Furthermore, energy efficient IoT devices running on batteries cannot afford the implementation of cryptography algorithms as such techniques have significant impact on the system power consumption. Therefore, in order to operate IoT in a secure manner, the system must be able to detect and prevent any kind of intrusions before the network (i.e., sensor nodes and base station) is destabilised by the attackers. In this article, we have presented an intrusion detection and prevention mechanism by implementing an intelligent security architecture using random neural networks (RNNs). The application’s source code is also instrumented at compile time in order to detect out-of-bound memory accesses. It is based on creating tags, to be coupled with each memory allocation and then placing additional tag checking instructions for each access made to the memory. To validate the feasibility of the proposed security solution, it is implemented for an existing IoT system and its functionality is practically demonstrated by successfully detecting the presence of any suspicious sensor node within the system operating range and anomalous activity in the base station with an accuracy of 97.23%. Overall, the proposed security solution has presented a minimal performance overhead.

9 November 2016 in IEEE Internet of Things Journal
Verified
Journal Article
Closed access
AJAbbas Javed
Abbas Javed
Hadi LarijaniHadi Larijani
Hadi Larijani
AAAli Ahmadinia
Ali Ahmadinia
RERohinton Emmanuel
Rohinton Emmanuel
MMMike Mannion
Mike Mannion
DGDesmond Gibson
Desmond Gibson
Building energy management systems (BEMSs) monitor and control the heating ventilation and air conditioning (HVAC) of buildings in addition to many other building systems and utilities. Wireless sensor networks (WSNs) have become the integral part of BEMS at the initial implementation phase or latter when retro fitting is required to upgrade older buildings. WSN enabled BEMS, however, have several challenges which are managing data, controllers, actuators, intelligence, and power usage of wireless components (which might be battery powered). The wireless sensor nodes have limited processing power and memory for embedding intelligence in the sensor nodes. In this paper, we present a random neural network (RNN)-based smart controller on a Internet of Things (IoT) platform integrated with cloud processing for training the RNN which has been implemented and tested in an environment chamber. The IoT platform is modular and not limited to but has several sensors for measuring temperature, humidity, inlet air coming from the HVAC duct and PIR. The smart RNN controller has three main components: 1) base station; 2) sensor nodes; and 3) the cloud with embedded intelligence on each component for different tasks. This IoT platform is integrated with cloud processing for training the RNN. The RNN-based occupancy estimator is embedded in sensor node which estimates the number of occupants inside the room and sends this information to the base station. The base station is embedded with RNN models to control the HVAC on the basis of setpoints for heating and cooling. The HVAC of the environment chamber consumes 27.12% less energy with smart controller as compared to simple rule-based controllers. The occupancy estimation time is reduced by our proposed hybrid algorithm for occupancy estimation that combines RNN-based occupancy estimator with door sensor node (equipped with PIR and magnetic reed switch). The results show that accuracy of hybrid RNN occupancy estimator is 88%.

11 September 2020 in Applied Computing and Informatics
Verified
Journal Article
Open access
Jawad AhmadJawad Ahmad
Jawad Ahmad
HLH. Larijani
H. Larijani
Rohinton EmmanuelRohinton Emmanuel
Rohinton Emmanuel
MMM. Mannion
M. Mannion
AJAbbas Javed
Abbas Javed
Buildings use approximately 40% of global energy and are responsible for almost a third of the worldwide greenhouse gas emissions. They also utilise about 60% of the world’s electricity. In the last decade, stringent building regulations have led to significant improvements in the quality of the thermal characteristics of many building envelopes. However, similar considerations have not been paid to the number and activities of occupants in a building, which play an increasingly important role in energy consumption, optimisation processes, and indoor air quality. More than 50% of the energy consumption could be saved in Demand Controlled Ventilation (DCV) if accurate information about the number of occupants is readily available (Mysen et al., 2005). But due to privacy concerns, designing a precise occupancy sensing/counting system is a highly challenging task. While several studies count the number of occupants in rooms/zones for the optimisation of energy consumption, insufficient information is available on the comparison, analysis and pros and cons of these occupancy estimation techniques. This paper provides a review of occupancy measurement techniques and also discusses research trends and challenges. Additionally, a novel privacy preserved occupancy monitoring solution is also proposed in this paper. Security analyses of the proposed scheme reveal that the new occupancy monitoring system is privacy preserved compared to other traditional schemes.

25 October 2018 in IT Professional
Verified
Journal Article
Closed access
AJAbbas Javed
Abbas Javed
HLHadi Larijani
Hadi Larijani
AWAndrew Wixted
Andrew Wixted
The critical requirements for devices connected to the Internet of Things are long battery life, long coverage range, and low deployment cost. The authors developed a machine-learning-based smart controller for a commercial buildings HVAC (heating, ventilation, and air conditioning) system using LoRa (a long-range, low-power wireless platform) and compared it with short-range RF communication in an indoor setting. Results show that LoRas coverage range was 60.4 percent more than short-range communication inside the building. The smart controller was capable of identifying when a room was unoccupied and turning off the HVAC, reducing its energy consumption up to 19.8 percent.

5 June 2024 in Future Internet
Verified
Journal Article
Open access
PDF file
AJAbbas Javed
Abbas Javed
AEAmna Ehtsham
Amna Ehtsham
MJMuhammad Jawad
Muhammad Jawad
MAMuhammad Naeem Awais
Muhammad Naeem Awais
AQAyyaz-ul-Haq Qureshi
Ayyaz-ul-Haq Qureshi
Hadi LarijaniHadi Larijani
Hadi Larijani
Smart home devices, also known as IoT devices, provide significant convenience; however, they also present opportunities for attackers to jeopardize homeowners’ security and privacy. Securing these IoT devices is a formidable challenge because of their limited computational resources. Machine learning-based intrusion detection systems (IDSs) have been implemented on the edge and the cloud; however, IDSs have not been embedded in IoT devices. To address this, we propose a novel machine learning-based two-layered IDS for smart home IoT devices, enhancing accuracy and computational efficiency. The first layer of the proposed IDS is deployed on a microcontroller-based smart thermostat, which uploads the data to a website hosted on a cloud server. The second layer of the IDS is deployed on the cloud side for classification of attacks. The proposed IDS can detect the threats with an accuracy of 99.50% at cloud level (multiclassification). For real-time testing, we implemented the Raspberry Pi 4-based adversary to generate a dataset for man-in-the-middle (MITM) and denial of service (DoS) attacks on smart thermostats. The results show that the XGBoost-based IDS detects MITM and DoS attacks in 3.51 ms on a smart thermostat with an accuracy of 97.59%.