The detection depth of current borehole acoustic reflection imaging is only tens of meters without high resolution. This considerably limits its wide application in the identification and fine description of unconventional reservoirs and in the optimization of drilling trajectories. Increasing the directional energy from the transmitter to a geological structure is an excellent way to solve this issue. In this study, a plasma source with a parabolic reflector was introduced during borehole acoustic reflection imaging. First, an experimental system was built for testing the plasma source. Next, the acoustic-electrical characteristics and directional radiation of the source were studied using experiments and a numerical simulation. Finally, the advantages, disadvantages, and feasibility of the plasma-transmitting source were analyzed; some suggestions for further work on the source and its logging application were proposed. The experimental and simulation results show that the use of a plasma source with a parabolic reflector can increase the detection depth of borehole acoustic reflection imaging to hundreds of meters with high resolution. This is crucial in imaging the geological structures near boreholes and enhancing oil–gas exploration and development.
To improve the performance of acoustic logging tool in detecting three-dimensional formation, larger and more complicated transducer arrays have been used, which will greatly increase the difficulty of fault diagnosis during tool assembly and maintenance. As a result, traditional passive diagnostic methods become inefficient, and very skilled assemblers and maintainers are required. In this study, fault-diagnosis requirement for the acoustic logging tool at different levels has been analyzed from the perspective of the tool designer. An intelligent fault-diagnosis system consisting of a master-slave hardware architecture and a systemic diagnosis strategy was developed. The hardware system is based on the embedded technology, while the diagnosis strategy is built upon fault-tree analysis and data-driven methods. Diagnostic practice shows that this intelligent system can achieve four levels of fault diagnosis for the acoustic logging tool: System, subsystem, circuit board, and component. This study provided a more rigorous and professional fault diagnosis during tool assembly and maintenance. It is expected that this proposed method would be of great help in achieving cost reduction and improving work efficiency.
A security-enhanced, spectral-efficient, and power-efficient multi-beam wireless communication scheme based on random frequency diverse array (RFDA) is proposed in this paper. (AN)-aided directional modulation (DM) schemes. Furthermore, with the aid of spatial modulation (SM) technology and cooperative legitimate users (LUs), we can transmit more information bits by the use of LU number informations than the single modulation symbols. Unlike conventional zero-forcing (ZF) beamforming for multi-beam DM, we design a FDA beamforming vector for each LU based on the minimum transmit power method. Numerical simulations show that (1) the proposed scheme is power-efficient compared to the conventional schemes, (2) the proposed scheme can transmit more information bits than the conventional schemes, and (3) the proposed scheme can ensure communication security when eavesdroppers (Eves) are proximal to LUs or even in same locations.
24 June 2020 in Wireless Communications and Mobile Computing
In this paper, we research synthesis scheme for secure wireless communication in multibeam directional modulation (MBDM) system, which consists of multiple legitimate users (LUs) receiving their own individual confidential messages, respectively, and multiple eavesdroppers (Eves) intercepting confidential messages. We propose a new type of array antennas, termed frequency diverse arrays (FDA), to enhance security of confidential messages. Leveraging FDA technology and artificial noise (AN) technology, we aim to address the PHY security problem for MBDM by jointly optimizing the frequency offsets, the precoding matrix and the AN projection matrix. In the first stage, with known locations of Eves, precoding matrix is designed to minimize Eve’s receiving power of confidential message (Min-ERP), while satisfying power requirement of LUs. And then artificial-noise projection matrix (ANPM) is calculated to enhance AN impact on Eves without influencing LUs. Furthermore, we research a more practical scenario, where locations of Eves are unknown. Unlike the scenario of the known locations of Eves, precoding matrix is designed to maximize AN transmit power (Max-ATP), while satisfying each LU’s requirement received power of confidential message. In the second stage, we analyze and further optimize secrecy capacity. The problem is solved by optimizing frequency offsets through modified artificial bee colony (M-ABC) algorithm. Numerical results show that the proposed scheme can achieve a secure transmission in MBDM system.
Piezoelectric transducers are commonly used in acoustic well logging. However, the low frequency and narrow range of the acoustic waves limit the achievable detection accuracy. In addition, the low amplitude of the waves causes useful information to be easily masked by noise during detection, which affects the accuracy of geological identification and makes it difficult to detect formations tens of meters away. This paper proposes a microporous liquid–electric transmission transducer, in which the microporous electrode structure generates a powerful shock wave through a high-energy instantaneous discharge. First, a model of the liquid–electric microporous transmitting transducer was constructed by combining simulations with numerical calculations, and its electro-acoustic characteristics were analyzed. Then, based on the survey requirements, two innovative optimization schemes for the microporous electrode structure were proposed, namely a triangular pyramid microporous electrode structure and a rectangular microporous electrode structure, and their performances were compared. The results show that the newly optimized triangular pyramid microporous electrode liquid–electric transducer generates acoustic waves with higher amplitude and a wider frequency range than conventional piezoelectric transducers and other microporous structures. It maintains high energy while achieving high frequencies, enabling detection at distances of up to hundreds of meters and the precise characterization of small geological bodies. This has significant implications for applications in marine exploration, land exploration, clean energy, and new energy fields.
The wave frequency and energy of traditional piezoelectric emission sources used in acoustic logging are limited, which results in an inadequate detection resolution for measuring small-scale geological formations. Additionally, the propagation of these waves in formations is prone to loss and noise interference, restricting detection to only a few tens of meters around the well. This paper investigates an impulse sound source, a new emission source that can effectively enhance the frequency range and wave energy of traditional sources by generating excitation waves through high-voltage discharges in a fluid-penetrated electrode structure. Firstly, a high-voltage circuit experimental system for the impulse sound source was constructed, and the discharge and response characteristics were experimentally analyzed. Then, four types of needle series electrode structure models were developed to investigate and compare the effects of different electrode structures on the impulse sound source, with the needle-ring electrode demonstrating superior performance. Finally, the needle-ring electrode structure was optimized to develop a ball-tipped needle-ring electrode, which is more suitable for acoustic logging. The results show that the electrode structure directly influences the discharge characteristics of the impulse sound source. After comparison and optimization, the final ball-tipped needle-ring electrode exhibited a broader frequency range—from zero to several hundred thousand Hz—while maintaining a high acoustic amplitude. It has the capability to detect geological areas beyond 100 m and is effective for evaluating micro-fractures and small fracture blocks near wells that require high detection accuracy. This is of significant importance in oil, gas, new energy, and other drilling fields.