Baiyong Men

Dr. Baiyong Men

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 June 2017 in Sensors
Verified
Journal Article
Open access
PDF file
YYYongchao Yao
Yongchao Yao
XJXiaodong Ju
Xiaodong Ju
JLJunqiang Lu
Junqiang Lu
BMBaiyong Men
Baiyong Men
A logging-while-drilling (LWD) caliper is a tool used for the real-time measurement of a borehole diameter in oil drilling engineering. This study introduces the mechanical structure and working principle of a new LWD caliper based on ultrasonic distance measurement (UDM). The detection range is a major performance index of a UDM system. This index is determined by the blind zone length and remote reflecting interface detection capability of the system. To reduce the blind zone length and detect near the reflecting interface, a full bridge acoustic emission technique based on bootstrap gate driver (BGD) and metal-oxide-semiconductor field effect transistor (MOSFET) is designed by analyzing the working principle and impedance characteristics of a given piezoelectric transducer. To detect the remote reflecting interface and reduce the dynamic range of the received echo signals, the relationships between the echo amplitude and propagation distance of ultrasonic waves are determined. A signal compensation technique based on time-varying amplification theory, which can automatically change the gain according to the echo arrival time is designed. Lastly, the aforementioned techniques and corresponding circuits are experimentally verified. Results show that the blind zone length in the UDM system of the LWD caliper is significantly reduced and the capability to detect the remote reflecting interface is considerably improved.

29 January 2025 in Sensors
Verified
Journal Article
Open access
PDF file
QZQin Zhenyu
Qin Zhenyu
JLJunqiang Lu
Junqiang Lu
BMBaiyong Men
Baiyong Men
SWShijie Wei
Shijie Wei
JPJiakang Pan
Jiakang Pan
The logging-while-drilling (LWD) acoustic logging instrument is pivotal in unconventional oil and gas exploration, and in providing real-time assessments of subsurface formations. The acquisition system, a core component of the LWD acoustic logging suite, is tasked with capturing, transmitting, and processing acoustic signals from the formation, which directly affects the accuracy and timeliness of the logging data. Recognizing the constraints of current LWD acquisition systems, including limited data collection capabilities and inadequate precision, this study introduces an FPGA-based multi-node data acquisition system for LWD acoustic logging. This system increases sampling density and data accuracy, leading to a more comprehensive collection of formation information. The multi-node acquisition system is composed primarily of a main control circuit board and several acquisition circuit boards, all connected via an RS485 bus. The Field-Programmable Gate Array (FPGA) is utilized to develop the acquisition circuit board’s firmware, offering adjustable control over parameters, such as the AD7380’s operational mode, sampling rate, and depth, facilitating real-time and concurrent acquisition and storage of formation acoustic signals. The main control board communicates with the acquisition boards via the RS485 bus, issuing commands to enable autonomous data collection and transfer from each board, thus enhancing the system’s reliability and scalability. Experimental results confirm the system’s capacity to efficiently capture waveform signals and upload them in real-time, underscoring its dependability and timeliness. The findings suggest that the system is capable of high-speed, real-time acquisition and processing of acoustic signals, offering robust technical support for the continued application of LWD acoustic logging instruments.

19 March 2023 in Sensors
Verified
Journal Article
Open access
PDF file
JLJunqiang Lu
Junqiang Lu
BMBaiyong Men
Baiyong Men
XCXiaohua Che
Xiaohua Che
Azimuthal acoustic logging can survey the downhole formation more accurately, and the acoustic source is the crucial component of the downhole acoustic logging tool with azimuthal resolution characteristics. To realize downhole azimuthal detection, assembling multiple transmitting piezoelectric vibrators in the circumferential direction is necessary, and the performance of azimuthal-transmitting piezoelectric vibrators needs attention. However, effective heating test and matching methods are not yet developed for downhole multi-azimuth transmitting transducers. Therefore, this paper proposes an experimental method to comprehensively evaluate downhole azimuthal transmitters; furthermore, we analyze the azimuthal-transmitting piezoelectric vibrator parameters. This paper presents a heating test apparatus and studies the admittance and driving responses of the vibrator at different temperatures. The transmitting piezoelectric vibrators showing a good consistency in the heating test were selected, and an underwater acoustic experiment was performed. The main lobe angle of the radiation beam, horizontal directivity, and radiation energy of the azimuthal vibrators and azimuthal subarray are measured. The peak-to-peak amplitude radiated from the azimuthal vibrator and the static capacitance increase with an increase in temperature. The resonant frequency first increases and then decreases slightly with an increase in temperature. After cooling to room temperature, the parameters of the vibrator are consistent with those before heating. Hence, this experimental study can provide a foundation for the design and matching selection of azimuthal-transmitting piezoelectric vibrators.

25 July 2019 in Sensors
Verified
Journal Article
Open access
PDF file
XHXiaolong Hao
Xiaolong Hao
XJXiaodong Ju
Xiaodong Ju
JLJunqiang Lu
Junqiang Lu
BMBaiyong Men
Baiyong Men
JZJing Zhou
Jing Zhou
To improve the performance of acoustic logging tool in detecting three-dimensional formation, larger and more complicated transducer arrays have been used, which will greatly increase the difficulty of fault diagnosis during tool assembly and maintenance. As a result, traditional passive diagnostic methods become inefficient, and very skilled assemblers and maintainers are required. In this study, fault-diagnosis requirement for the acoustic logging tool at different levels has been analyzed from the perspective of the tool designer. An intelligent fault-diagnosis system consisting of a master-slave hardware architecture and a systemic diagnosis strategy was developed. The hardware system is based on the embedded technology, while the diagnosis strategy is built upon fault-tree analysis and data-driven methods. Diagnostic practice shows that this intelligent system can achieve four levels of fault diagnosis for the acoustic logging tool: System, subsystem, circuit board, and component. This study provided a more rigorous and professional fault diagnosis during tool assembly and maintenance. It is expected that this proposed method would be of great help in achieving cost reduction and improving work efficiency.

11 November 2016 in Journal of Geophysics and Engineering
Verified
Journal Article
Closed access
PDF file
BMBaiyong Men
Baiyong Men
XJXiaodong Ju
Xiaodong Ju
JLJunqiang Lu
Junqiang Lu
WQWenxiao Qiao
Wenxiao Qiao
In high-temperature and spatial borehole applications, a distributed structure is employed in a multidimensional array acoustic logging tool (MDALT) based on a phased array technique for electronic systems. However, new challenges, such as synchronous multichannel data acquisition, multinode real-time control and bulk data transmission in a limited interval, have emerged. To address these challenges, we developed a synchronous serial bus (SSB) in this study. SSB works in a half-duplex mode via a master–slave architecture. It also consists of a single master, several slaves, a differential clock line and a differential data line. The clock line is simplex, whereas the data line is half-duplex and synchronous to the clock line. A reliable communication between the master and the slaves with real-time adjustment of synchronisation is achieved by rationally designing the frame format and protocol of communication and by introducing a scramble code and a Hamming error-correcting code. The control logic of the master and the slaves is realized in field programmable gate array (FPGA) or complex programmable logic device (CPLD). The clock speed of SSB is 10 MHz, the effective data rate of the bulk data transmission is over 99%, and the synchronous errors amongst the slaves are less than 10 ns. Room-temperature test, high-temperature test (175 °C) and field test demonstrate that the proposed SSB is qualified for MDALT.

20 December 2021 in Sensors
Verified
Journal Article
Open access
PDF file
LZLiangchen Zhang
Liangchen Zhang
XJXiaodong Ju
Xiaodong Ju
JLJunqiang Lu
Junqiang Lu
BMBaiyong Men
Baiyong Men
WHWeiliang He
Weiliang He
To increase the accuracy of reservoir evaluation, a new type of seismoelectric logging instrument was designed. The designed tool comprises the invented sonde-structured array complex. The tool includes several modules, including a signal excitation module, data acquisition module, phased array transmitting module, impedance matching module and a main system control circuit, which are interconnected through high-speed tool bus to form a distributed architecture. UC/OS-II was used for the real-time system control. After constructing the experimental measurement system prototype of the seismoelectric logging detector, its performance was verified in the laboratory. The obtained results showed that the consistency between the multi-channel received waveform amplitude and benchmark spectrum was more than 97%. The binary phased linear array transmitting module of the instrument can realize 0° to 20° deflection and directional radiation. In the end, a field test was conducted to verify the tool’s performance in downhole conditions. The results of this test proved the effectiveness of the developed seismoelectric logging tool.