This paper proposes a fiber optic Fabry-Perot (F-P) strain sensing system using non-scan correlation demodulation applied to the health monitoring of the pressurized water reactor’s fuel assembly structures. The structural design and sensing mechanism analysis of the sensor were carried out, and the strain transfer model from the fuel sheet to the strain gauge was established. After the sensor fabrication and installation, the static tests have been conducted, and the results indicate that the sensing system can accurately measure the microstrain with a sensitivity of up to 12.6 nm/με at a high temperature (300 °C). The dynamic testing shows that the sensing system has a good frequency adaptation at 10–500 Hz. Thermal-hydraulic experiments show that the sensing system can run stably in a nuclear reactor, with high temperature, high pressure, and high-velocity flow flushing; additionally, the consistency deviation of the measured data is less than 1.5%.
Three kinds of reusable surface enhanced Raman scattering (SERS) substrates based on Ag-TiO2-G, Ag-G-TiO2 and G-Ag-TiO2 hybrid structures were prepared by a combination method of simple sol-gel self-assembly and annealing. The composites were confirmed by transmission electron microscopy (TEM) and energy-dispersive X-ray spectroscopy (EDS). Raman mapping spectra of the three hybrids were analyzed in order to study the difference of charge transfer between Ag, TiO2 and graphene. In addition, rhodamine 6G (R6G) was used as the probe analyte, and the SERS activity of the three structures decreased orderly in the sequence of Ag-G-TiO2, G-Ag-TiO2, and Ag-TiO2-G, with the enhancement factor of about 106, which was due to the high electromagnetic enhancement of the Ag nanoparticles (AgNPs). The photo-catalytic properties of the three kinds of composites were experimentally studied via Raman mapping measurements through UV irradiation. The photocatalytic ability decreased also orderly in the sequence of Ag-G-TiO2, G-Ag-TiO2, and Ag-TiO2-G, and the reason was discussed in details.
In this study, we present a dual-Fizeau-interferometer-based high-speed and wide-range fiber-optic Fabry-Perot (F-P) demodulation system. We employ two Fizeau interferometers with air cavity thickness satisfying the quadrature requirement to increase the demodulation speed and broaden the demodulation range in order to address the issues of the existing fiber F-P demodulation system’s sluggish demodulation rate and limited range. In order to investigate the demodulation properties of the dual-Fizeau-interferometer-based demodulation system, we derive and create a theoretical model of the system. The theoretical model, which primarily consists of the structural design of the interferometer and the study of the center wavelength of the light sources and their bandwidth selection, is used to construct the optical structure of the demodulation system. According to the calculation results, the demodulated signal exhibits the best contrast ratio when the two light sources’ respective center wavelengths are 780 nm and 850 nm, and their bandwidths are 28 nm and 30 nm. Finally, we finish evaluating the demodulation system’s demodulation performance, parameter calibration, and assembly debugging. The test results demonstrate the constant operation of the demodulation system, an update rate of 100 kHz, a demodulation range of 4.74 µm, and a cavity length resolution of approximately 5 nm. Additionally, the system can perform high speed demodulation thanks to the light emitting diode’s (LED’s) nanosecond level switching speed and the usage of a single point detector.
8 December 2021 in Journal of Physics D: Applied Physics
Hydrogen sulfide (H2S) gas has a severe effect on the respiratory system of the human body and ambient environment, necessitating development of on-line H2S gas sensors with high performance for safety and health concerns. Here, we proposed a fiber-optic surface plasmon resonance sensor for H2S detection employing TiO2 nanoparticles and multilayer carbon nanotubes composite (TiO2/MWCNT) as sensing film, featuring desirable advantages of high sensitivity, selectivity, and real-time detection. Benefiting from special structure and large specific surface area of MWCNTs, the adsorption capacity of sensing surface to gas molecules can be significantly enhanced. Moreover, the high carrier mobility of MWCNTs can further promote the charge transfer between TiO2 and H2S. These unique features of TiO2/MWCNT composite film result in an obvious improvement of sensitivity for H2S detection. Experimental results show that the maximum sensitivity of 21.76 pm ppm−1 (picometer/part-per-million) and detection limit of 0.2 ppm can be obtained by appropriately optimizing the componential constitutions of TiO2/MWCNT composite. Such detection limit is strikingly lower than the threshold concentrations in workplace set by Federal Institute for Occupational Safety (10 ppm). In addition, the favorable selectivity, response/recovery times, repeatability and stability were demonstrated as well. This facile and cost-effective work provides a novel strategy for constructing high performance H2S gas sensor with fast response and real-time detection, which has prospective application in the fields of human health and environmental conservation.
A Raman sensor based on a cavity-enhanced Ag nanoparticle (AgNP) decorated tapered fiber is proposed. Its Raman enhancements are mainly caused by the localized surface plasmon resonance effect of AgNPs decorated on the tapered optical fiber surface and the further reflective laser excitation induced by the capillary-based reflective cavity. We theoretically investigate the backward Stokes power conversion efficiency and cavity enhancement factor of the sensor. The calculated relationship between the cavity enhancement factor and distance L from the tip to reflective rod is also discussed. Subsequently, the proving experiments were carried out for a tapered fiber surface-enhanced Raman scattering (SERS) probe and cavity-enhanced metal decorated tapered fiber Raman sensors. The analytical enhancement factor is for the tapered fiber SERS probe. Moreover, the predicted curves of the theoretical model are close to the experimental values. This Letter provides a possible way to rigorously quantify the complete coupling efficiency for tapered fiber SERS probes, as well as cavity enhancement factors of cavity-enhanced Raman sensors.