omar aljasim

Dr. omar aljasim

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 April 2021 in TURKISH JOURNAL OF MEDICAL SCIENCES
Verified
Journal Article
Open access
AÖAnıl Murat Öztürk
Anıl Murat Öztürk
OAomar aljasim
omar aljasim
GŞGamze Şanlidağ
Gamze Şanlidağ
MTMeltem Taşbakan
Meltem Taşbakan
This study aimed to retrospectively analyse patients with foreign body (FB) injuries in our hospital and to present a patient with missed penetrating sponge FB injury. This study lasted 12 years (2008–2020) and reviewed all patients with FB injuries who were admitted to the emergency department (ED) of our hospital. Along with our overall results, we present a case with missed penetrating sponge FB injury in detail. Approximately 377 patients were included in the study (age: 28.3 ± 18.3 years, m/f: 229/148). The foot (n = 148, 39.3%) and the hand (n = 143, 37.9%) were the most frequently injured body parts. Regarding FB types, sewing needles (n = 140, 37.1%), metal pieces (n = 91, 24.1%), and glass (n = 80, 21.2%) were the most frequently observed objects. Most of the patients were injured at home, often by needles or glass. The injury-admission mean time was 7.38 ± 2.5 days. FBs were frequently removed in the ED (n = 176, 46.7%). Plain radiography is the first line in identifying FBs. Soft tissue infection was the most common complication. MRIs were much useful than USGs in detecting the missed penetrating sponge injury of the single patient in the study. For diagnosis of FBs, besides recording the patient’s history, obtaining a two-sided radiogram is of great importance. For nonradiolucent or deeply located FBs, further clinical or radiological investigation must be considered to avoid complications. Although most of the FBs can be removed in the ED, patients may require hospitalisation and operation for FB removal, depending upon FB location and age.


26 April 2023 in Joint Diseases and Related Surgery
Verified
Journal Article
Open access
PDF file
ADAli Engin Daştan
Ali Engin Daştan
AVArman Vahabi
Arman Vahabi
OAomar aljasim
omar aljasim
BKBünyamin Kılıçlı
Bünyamin Kılıçlı
LKLevent Küçük
Levent Küçük
ECErhan Coşkunol
Erhan Coşkunol
Joint Diseases and Related Surgery (JDRS), the official journal of the Turkish Joint Diseases Foundation, is an international, peer-reviewed, immediate open access journal. All published articles in JDRS has been free for everyone, without embargo, since 1990.

22 July 2024 in Journal of Orthopaedic Surgery and Research
Verified
Journal Article
Open access
PDF file
OAomar aljasim
omar aljasim
CYCan Yener
Can Yener
NÖNadir Özkayın
Nadir Özkayın
Introduction: Femoral neck fractures have posed a significant global healthcare challenge and had notable impacts on the quality of life. Current treatment strategies for femoral neck fractures in young individuals have varied, emphasizing the need for optimal fixation methods. This study compared the clinical and radiological outcomes of the dynamic compression system (DCS) and multiple cancellous screws (MCS) methods. Methods: This retrospective study included a total of 275 young adults with fresh femoral neck fractures treated with DCS and MCS. A matching analysis with a 1:1 ratio based on age, gender, fracture classification, and reduction quality was conducted. Demographic data were recorded, and comparisons were made according to follow-up time (FUT), hospitalization period, operation duration, femoral neck shortening, caput-collum-diaphysis (CCD) angle, Harris Hip Score (HHS), and post-operative complications. Results: A total of 42 fractures were matched with a median age of 42 years (range, 22–48). In the DCS group, vertical neck shortening (median 1.92) was significantly lower than that in the MCS group (median 4.53) (P < 0.05). In the DCS group, horizontal femoral neck shortening, resultant femoral neck shortening, the amount of change in CCD angle, and HHS were 0.57 mm (0.43, 4.74 mm), 1.82 mm (0.40, 3.53 mm), 0.13° (-0.78°, 1.80°), and 91 (85–93), respectively. They were all non-significant than 1.00 mm (0.56, 6.23 mm), 2.74 mm (1.59, 6.71 mm), -0.18° (-1.11°,1.85°), and 91 (75, 93) in the MCS group, respectively (P > 0.05). There was no statistical difference in FUT, hospitalization period, operation time, and post-operative complications at the latest follow-up (P > 0.05). There were no complications such as pulmonary embolism, deep vein thrombosis, and incision infection reported. Conclusion: DCS and MCS demonstrated effectiveness in treating femoral neck fractures in young adults. The DCS implant provides additional stability in the vertical axis. A prospective randomized controlled study with a large sample size was needed to validate these findings.

25 April 2025 in Journal of Hand and Microsurgery
Verified
Journal Article
Closed access
OAomar aljasim
omar aljasim
CYCan Yener
Can Yener
MDMesut Demirkoparan
Mesut Demirkoparan
AVArman Vahabi
Arman Vahabi
ADAli Engin Daştan
Ali Engin Daştan
HGHüseyin Günay
Hüseyin Günay

21 June 2025 in Journal of Hand and Microsurgery
Verified
Journal Article
Closed access
ADAli Engin Daştan
Ali Engin Daştan
OAomar aljasim
omar aljasim
RCRüstem Celil
Rüstem Celil
YÖYavuz Önel
Yavuz Önel
AVArman Vahabi
Arman Vahabi