The aim of this study was to compare the efficiency of dorsal tangential fluoroscopy and ultrasonography in detecting dorsal screw penetration in distal radius volar locking plate applications. Ten cadaveric forearms were operated. The distal four screws were protruded 0, 1 and 2?mm into each of the second, third and fourth dorsal compartments of distal radius. Dorsal horizon views were taken using fluoroscopy. Each radiographic image was evaluated by two orthopedic surgeons who are blinded to procedure. Sonographic evaluations were performed by an orthopedic surgeon blinded to the procedure. Both dorsal horizon view and ultrasonography assessments were noted by the evaluators whether the tip of the screw penetrated or not the dorsal cortex for each compartment. No significant difference was observed on correct detection of 0?mm, 1?mm and 2?mm screw penetrations at second and third compartments. In the fourth compartment, there was no difference with 0?mm and 2?mm penetrations but correct detection accuracy of 1?mm screw penetration was 87% in ultrasonography group and 71% in dorsal horizon view group. The accuracy of ultrasonography on 1?mm penetration at the fourth compartment is better than dorsal horizon view. However, dorsal horizon view and ultrasonography accuracy is similar for the other compartments and penetration levels. Ultrasonography is a reliable and effective procedure for detection of dorsal screw penetrations. Level III, Diagnostic study. ER - Keywords Distal radius fracture Volar plating Complications Ultrasound Tendon rupture
This study aimed to evaluate the differences between mini-open (MO) and arthroscopic (ART) repair procedures for rotator cuff tendon tears in terms of clinical and radiological outcomes. This retrospective study included 59 patients, and data were collected prospectively. Patients with full-thickness rotator cuff tears were randomized to undergo MO or ART repair at 2 centers by 2 surgeons between January 2012 and December 2017. Data were collected 3 weeks before surgery and 6 and 12 months after surgery. Physical function was assessed using the American Shoulder and Elbow Surgeons index, VAS, and Constant scoring system. Radiological outcomes were assessed using the Sugaya classification, adapted for ultrasound. Changes between baseline and follow-up were compared between the 2 groups. Fifty-nine patients who underwent ART or MO rotator cuff repair were included in this study. The 2 groups had similar demographic characteristics and preoperative baseline parameters. Both the MO and ART groups showed statistically significant improvement in outcome parameters (P ≤ .0001); however, cuff repair integrity was significantly better in the ART group (P = .023). All other improvements in the patient-derived parameters were equivalent. None of the patients in either group required revision surgery. According to the results of our retrospective study, MO and ART rotator cuff repair are effective and viable options for surgeons to repair rotator cuff tears. There were no differences in objective and subjective outcomes between the full ART and MO techniques for rotator cuff tears. Surgeons should choose a technique with which they are more familiar.
22 March 2017 in The Journal of Pediatric Research
Aim: We aimed to evaluate the clinical and radiological results of an intramedullary fixation system used in surgeries for fractures and deformities of osteogenesis imperfecta where we applied a new design corkscrew tipped intramedullary nailing.\ud Materials and Methods: Twenty extremities of 14 osteogenesis cases, who underwent surgery and to whom corkscrew tipped intramedullary treatment was applied, were retrospectively scanned. Ambulation, discrepancies in the lenght of extremities, deformities and joint mobility range were all noted before the operation. Postoperative union rates, complications and our experience regarding the nail were also evaluated.\ud Results: Six tibia and 14 femurs were operated using corkscrew tipped telescopic nails. Two bones were operated due to non-union, while seven bones underwent surgery due to acute fractures and 11 bones due to deformities. All the bones were seen to have achieved the aimed union. No major complications were observed. Infection was present in two cases.\ud Conclusion: Corkscrew tipped telescopic nail is a safe and effective method of fixation in patients with osteogenesis imperfecta
26 April 2023 in Joint Diseases and Related Surgery
Joint Diseases and Related Surgery (JDRS), the official journal of the Turkish Joint Diseases Foundation, is an international, peer-reviewed, immediate open access journal. All published articles in JDRS has been free for everyone, without embargo, since 1990.
Background: It is important for orthopedic surgeons to follow the union of the fracture after surgery. This becomes even more important after nonunion surgery. The radiological union scale is popular in the follow-up of unions. However, the intraobserver and interobserver agreement of this scale in humeral nonunion surgery is still not found in the literature. Objective: This study aimed to reveal the intra/interobserver agreement of the Radiographic Union scale (RHUM) for the humerus as well as the relationship between this agreement, plate placement characteristics, and the number of plates in cases where plates were used for surgical treatment of humeral diaphysis nonunion. Material and Methods: Twenty patients who received surgical treatment for aseptic humeral nonunion at our hospital between 2010-2019 were studied retrospectively. Two observers scored the patients' anteroposterior and lateral radiographs in the postoperative 12th week according to RHUM. The data obtained were statistically analyzed. Results: The mean age was 52.05±15.88 years. While a single plate was used in 14 cases, a double plate was used in 6 cases. Interobserver agreement was fair-moderate. The interobserver agreement values of the single plate group were significantly higher than those of the double plate group (p<0.05). Interobserver agreement in cases with lateral plate was significantly higher than in the group in which the lateral + posterior plate was applied (p:0.01). Conclusion: In cases of humeral diaphyseal fracture nonunion, the number and location of the plate following surgery have a negative impact on the evaluation of RHUM scores. Given the importance of the union's follow-up and the decision to proceed with additional treatment in these cases, it may be necessary to develop a new method for determining and monitoring the union if a plate was used in the surgical treatment of humeral nonunion.