Stefan Benedikt

Dr. Stefan Benedikt

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 June 2019 in Operative Orthopädie und Traumatologie
Verified
Journal Article
Open access
PDF file
DKDietmar Krappinger
Dietmar Krappinger
RLRichard A. Lindtner
Richard A. Lindtner
SBStefan Benedikt
Stefan Benedikt
Preoperative planning of the starting point and safe trajectory for iliosacral screw (SI screw) fixation using CT scans for safe and accurate fluoroscopically controlled percutaneous SI screw placement.

1 November 2017 in Journal of Plastic, Reconstructive & Aesthetic Surgery
Verified
Journal Article
Closed access
SBStefan Benedikt
Stefan Benedikt
DPD. Parvizi
D. Parvizi
GFG. Feigl
G. Feigl
HKH. Koch
H. Koch

2 August 2021 in Archives of orthopaedic and trauma surgery
Verified
Journal Article
Open access
PDF file
SBStefan Benedikt
Stefan Benedikt
PKPeter Kaiser
Peter Kaiser
GSGernot Schmidle
Gernot Schmidle
TKTobias Kastenberger
Tobias Kastenberger
KSKerstin Stock
Kerstin Stock
RARohit Arora
Rohit Arora
Introduction: Recently, the Cobra prostheses were introduced in the treatment of distal radius fractures (DRF) of elderly patients. Fracture prostheses provide an alternative treatment option for complex fractures where conservative therapy seems not acceptable and osteosynthesis seems not possible. Data reporting the feasibility of the Cobra prosthesis are sparse. Therefore, this retrospective follow-up study investigated the clinical and radiological mid-term outcome of the Cobra implant in complex DRFs of elderly patients.Materials and methods: Thirteen patients (mean age 73.5 years, range 65–87 years) were retrospectively evaluated with at least a 1-year follow-up after surgery. Objective and subjective clinical parameters as well as the radiological outcome and complications were analyzed.Results: The mean follow-up period was 31.2 months. Seven cases required a cemented prosthesis. The mean relative range-of-motion compared to the healthy side was 72.3% and 51.8% for extension and flexion, respectively, and 87.9% and 85.7% for pronation and supination, respectively. The mean grip strength was 78.3% compared to the non-operated side. Eight patients were very satisfied, five patients were partly satisfied with the result. The DASH, PRWE, MHQ and Lyon-Scores averaged 39.1, 36.2, 64.9 and 63.3 points, respectively. The mean VAS-Score for pain was 1.1 at rest and 3.2 during activities. Perioperative complications included one dissection of the extensor pollicis longus tendon, one heterotopic ossification, one radiocarpal dislocation and two cases of an ulnar impaction syndrome due to implant subsidence.Conclusion: The prosthetic treatment of complex DRFs in elderly patients with the Cobra implant led to clinically and radiologically satisfactory mid-term results. The Cobra prosthesis still does not represent a gold standard but can be regarded as a feasible salvage option for complex DRFs when osteosyntheses may not be possible and non-operative treatment will lead to further functional restrictions and wrist pain during performing activities of daily life in high functional demand patients.

15 January 2022 in Archives of orthopaedic and trauma surgery
Verified
Journal Article
Open access
PDF file
TKTobias Kastenberger
Tobias Kastenberger
PKPeter Kaiser
Peter Kaiser
SBStefan Benedikt
Stefan Benedikt
KSKerstin Stock
Kerstin Stock
MEMagdalena Eigl
Magdalena Eigl
RARohit Arora
Rohit Arora
Introduction: The aim of this study was to provide a more precise statement on the outcome after surgical treatment of a bony mallet thumb and possibly give a treatment recommendation regarding the surgical fixation method. Patients and methods: All patients (n = 16) who underwent a surgical treatment for an acute bony mallet thumb fracture between January 2006 and July 2019 were enrolled. The surgical method, complications, the range of motion, tip pinch, lateral key pinch, overall grip strength, visual analog score, Disability of the Arm, Shoulder and Hand Score, Mayo Wrist Score, Patient-Rated Wrist Evaluation Score, Buck-Gramcko Score and radiologic parameters were evaluated. Further, a comprehensive literature search on PubMed was conducted covering a period from 1956 to 2021 to include all possible matching articles on the treatment of the bony mallet thumb (n = 21 articles). Results: Surgical treatment was very inhomogenous including indirect and direct K-wire fixation, screw fixation, plate fixation and anchor fixation methods. The IP joint range of motion and thumb strength ranged from 66 to 94% in comparison to the contralateral side. An open reduction led to worse functional scores compared to a closed reduction. Treatment methods in the literature were also very inhomogenous with a very low patient count, often even pooling data of bony mallet thumb fractures with bony mallet finger fractures. The risk for infection was higher in K-wire fixation methods than in open reduction and internal fixation methods. Conclusion: The evidence for the best treatment of a bony mallet thumb fracture is low. On one hand the functional outcome can be inferior using an open reduction approach, but on the other hand, K-wire fixation methods with a closed reduction approach showed a higher risk for infection. Future multi-center research must be conducted to find the best treatment procedure for the best outcome of the patient.

6 March 2024 in Diagnostics
Verified
Journal Article
Open access
PDF file
SBStefan Benedikt
Stefan Benedikt
PZPhilipp Zelger
Philipp Zelger
LHLukas Horling
Lukas Horling
KSKerstin Stock
Kerstin Stock
Johannes Dominikus PalluaJohannes Dominikus Pallua
Johannes Dominikus Pallua
RARohit Arora
Rohit Arora
In vivo high-resolution peripheral quantitative computed tomography (HR-pQCT) studies on bone characteristics are limited, partly due to the lack of standardized and objective techniques to describe motion artifacts responsible for lower-quality images. This study investigates the ability of such deep-learning techniques to assess image quality in HR-pQCT datasets of human scaphoids. In total, 1451 stacks of 482 scaphoid images from 53 patients, each with up to six follow-ups within one year, and each with one non-displaced fractured and one contralateral intact scaphoid, were independently graded by three observers using a visual grading scale for motion artifacts. A 3D-CNN was used to assess image quality. The accuracy of the 3D-CNN to assess the image quality compared to the mean results of three skilled operators was between 92% and 96%. The 3D-CNN classifier reached an ROC-AUC score of 0.94. The average assessment time for one scaphoid was 2.5 s. This study demonstrates that a deep-learning approach for rating radiological image quality provides objective assessments of motion grading for the scaphoid with a high accuracy and a short assessment time. In the future, such a 3D-CNN approach can be used as a resource-saving and cost-effective tool to classify the image quality of HR-pQCT datasets in a reliable, reproducible and objective way.

26 November 2024 in Bone
Verified
Journal Article
Open access
SBStefan Benedikt
Stefan Benedikt
KSKerstin Stock
Kerstin Stock
LHLukas Horling
Lukas Horling
GSGernot Schmidle
Gernot Schmidle
MSMichael Schirmer
Michael Schirmer
RARohit Arora
Rohit Arora
The exact mechanisms of bone remodelling after scaphoid fractures are not fully understood. Blood supply may lead to delayed consolidation and non-unions as challenging long-term problems. The aim of this study was to follow-up the microstructure during the scaphoid bone remodelling process using High Resolution peripheral Quantitative Computed Tomography (HR-pQCT) and compare the results with clinical and laboratory data. In this monocentric, prospective, controlled, clinical trial 39 patients with an unilateral conservatively treated scaphoid fracture at the level of the waist or the distal pole were followed up over one year (2, 4, 6, 12, 26 and 52 weeks after trauma). Fracture healing was monitored by clinical examination, blood bone remodelling markers and HR-pQCT. The HR-pQCT showed significant changes in trabecular number, trabecular thickness, trabecular separation and bone mineral density until the 52 week follow-up. Complete bony consolidation on HR-pQCT was evident in half of the fractures at 12 weeks and in all fractures at 52 weeks after trauma. None of the patients developed a non-union. Carboxy-terminal collagen crosslinks as resorption marker showed significant changes until the 52 week follow-up. This study shows detailed clinical, laboratory and radiologic changes during follow-up of uncomplicated fracture healing of conservative scaphoids. Bony consolidation is highly variable and can take up to one year after fracture. Larger studies are warranted, as HR-pQCT might provide detailed microstructural information to better predict fracture healing processes, thus acting as a high-resolution and low-radiation alternative to standard conventional CT.