Lukas Horling

Dr. Lukas Horling


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 March 2024 in Diagnostics
Verified
Journal Article
Open access
PDF file
SBStefan Benedikt
Stefan Benedikt
PZPhilipp Zelger
Philipp Zelger
LHLukas Horling
Lukas Horling
KSKerstin Stock
Kerstin Stock
Johannes Dominikus PalluaJohannes Dominikus Pallua
Johannes Dominikus Pallua
RARohit Arora
Rohit Arora
In vivo high-resolution peripheral quantitative computed tomography (HR-pQCT) studies on bone characteristics are limited, partly due to the lack of standardized and objective techniques to describe motion artifacts responsible for lower-quality images. This study investigates the ability of such deep-learning techniques to assess image quality in HR-pQCT datasets of human scaphoids. In total, 1451 stacks of 482 scaphoid images from 53 patients, each with up to six follow-ups within one year, and each with one non-displaced fractured and one contralateral intact scaphoid, were independently graded by three observers using a visual grading scale for motion artifacts. A 3D-CNN was used to assess image quality. The accuracy of the 3D-CNN to assess the image quality compared to the mean results of three skilled operators was between 92% and 96%. The 3D-CNN classifier reached an ROC-AUC score of 0.94. The average assessment time for one scaphoid was 2.5 s. This study demonstrates that a deep-learning approach for rating radiological image quality provides objective assessments of motion grading for the scaphoid with a high accuracy and a short assessment time. In the future, such a 3D-CNN approach can be used as a resource-saving and cost-effective tool to classify the image quality of HR-pQCT datasets in a reliable, reproducible and objective way.

1 March 2023 in Quantitative Imaging in Medicine and Surgery
Verified
Journal Article
Open access
PDF file
SBStefan Benedikt
Stefan Benedikt
LHLukas Horling
Lukas Horling
KSKerstin Stock
Kerstin Stock
GDGerald Degenhart
Gerald Degenhart
JPJohannes Pallua
Johannes Pallua
RARohit Arora
Rohit Arora
Original Article The impact of motion induced artifacts in the evaluation of HR- pQCT scans of the scaphoid bone: an assessment of inter- and intraobserver variability and quantitative parameters Stefan Benedikt, Lukas Horling, Kerstin Stock, Gerald Degenhart, Johannes Pallua, Gernot Schmidle, Rohit Arora