Omar fawzi Chawshli

Prof. Omar fawzi Chawshli

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 July 2023 in Orthodontics & Craniofacial Research
Verified
Journal Article
Open access
OCOmar fawzi Chawshli
Omar fawzi Chawshli
HAHasan Sabah Al-Nuaimi
Hasan Sabah Al-Nuaimi
FYFedil Andraws Yalda
Fedil Andraws Yalda
SAShaho Z. Al‐Talabani
Shaho Z. Al‐Talabani
Background and Objectives: The intrusion of anterior teeth is a routine procedure in orthodontics, which has been performed efficiently with the help of mini-screws in the anterior region, especially the upper maxilla. This study aimed to investigate the effect of insertion angle and sociodemographic features on the success rate of mini-screws at the anterior maxillary region. Materials and Methods: Twenty-nine patients (18 Females and 11 Males) aged 18-40 years old were involved in the current study. A split-mouth design was carried out in which recruited patients needed bilateral anterior screws at the labial bone in the region of the incisor for the intrusion of upper anterior incisor teeth as part of their orthodontic treatment with a fixed appliance (upper right side received 90-degree insertion angle mini-screw and 45 degrees for left side) using a surgical guide fabricated from patients CBCT and intraoral scans. The mini-screws were inserted at the attached gingiva bilaterally to achieve intrusion of upper anterior teeth with a power chain ligated from the main archwire to the anterior min-implants. The patient was recalled monthly for orthodontic appliance activation and screw assessment for 6 months. The intrusion force was 15 g on each side. Results: The results of the study showed that screw stability was higher in the male group than the female group at the 6th monthly follow-up visit with a statistically significant difference between both genders (P =.044). Concerning insertion angle, results showed a statistically significant difference between 45 degrees and 90 degrees as an insertion angle with a P-value <.01 in most of the follow-up months. Conclusion: This study found that male patients with mini-screws inserted at 90 degrees showed greater screw stability over time.

1 January 2024 in International Journal of Dentistry
Verified
Journal Article
Open access
FYFedil Andraws Yalda
Fedil Andraws Yalda
OCOmar fawzi Chawshli
Omar fawzi Chawshli
SAShaho Ziyad Al-Talabani
Shaho Ziyad Al-Talabani
SASarkawt Hamad Ali
Sarkawt Hamad Ali
OSOmed Shihab
Omed Shihab
Objectives. This study aimed to evaluate and compare palatal thickness in adults for the placement of mini‐implants for miniscrew‐assisted rapid palatal expansion (MARPE) appliances using cone‐beam computed tomography (CBCT) in a sample of Iraqi‐Kurdish people. Materials and Methods. CBCT scans from 68 Kurdish patients, aged between 18 and 30 years, were assessed retrospectively. Of these, 37 were males and 31 were females. The measurements were performed at 3 mm from the mid‐palatal suture. T‐zone was selected for the anterior points, at the level of the palatal cusps of 2nd premolars, and the posterior point at the level of mesio‐palatal cusps of 1st molars bilaterally. Palatal thickness of males and females bilaterally, as well as anterior and posterior areas, were measured and compared. An independent t‐test was applied for comparison for normally distributed data, and the Mann–Whitney test was utilized for nonnormally distributed data. Additionally, Bonferroni correction was implemented for p‐value adjustment. Results. The mean palatal thickness at the anterior area was 6.06 mm for males, 6.17 mm for females on the right side, 5.94 mm for males, and 5.99 mm for females on the left side. The mean palatal thickness at the posterior area was almost the same for both genders (4.40 mm for males and 4.44 mm for females) on the right side, 4.35 mm for males, and 4.54 mm for females on the left side. Statistically, no significant difference was recorded between males and females, as well as right and left sides in both anterior and posterior regions; however, a very highly statistically significant difference (p < 0.001) was recorded when comparing total thickness, including both hard and soft tissue, between anterior and posterior regions. Conclusions. CBCT proves a highly effective modality in assessing palatal thickness and suggesting ideal locations for orthodontic mini‐screw placement. Our examination of palatal thickness in a sample of Iraqi‐Kurdish individuals revealed no statistical difference between genders or sides, but significant variations were noted between anterior and posterior thicknesses. Comprehensive clinical and pre‐expansion CBCT evaluations are crucial for precisely determining the optimal placement of MARPE devices in each patient, ensuring successful outcomes.

Verified
Journal Article
Open access
PDF file
Can-Florian Dr. KelesCan-Florian Dr. Keles
Can-Florian Dr. Keles
DMDavid Morais
David Morais
Anand MaryaAnand Marya
Anand Marya
OCOmar fawzi Chawshli
Omar fawzi Chawshli
AVADITH VENUGOPAL
ADITH VENUGOPAL
Ute BotzenhartUte Botzenhart
Ute Botzenhart
Objectives: This narrative review aims to redefine Open Mouth Posture Syndrome (OMPS) as a multifactorial condition with overlapping symptoms and a cyclical pathophysiology. A novel classification system for OMPS subtypes is proposed to standardize research approaches and enhance clinical understanding. Methods: An interdisciplinary literature review was conducted, focusing on structural, functional, and adaptive mechanisms underlying OMPS. Subtype definitions were refined based on recent findings. Results: OMPS is categorized into five subtypes: Obstructive, Habitual, Anatomical, Sleep-Disordered Breathing, and Tongue-Related Pathologies. These subtypes share interconnected etiologies and manifestations, contributing to a feedback loop that complicates diagnosis and management. Conclusions: This classification system lays the foundation for future research and clinical protocols, emphasizing the need for a systematic approach to understanding OMPS.

4 December 2022 in Journal of Orthodontics
Verified
Journal Article
Closed access
DBDina Jawhar Butrus
Dina Jawhar Butrus
OCOmar fawzi Chawshli
Omar fawzi Chawshli
Introduction: Interproximal enamel reduction is a part of the orthodontic treatment as a method of space generation in addition to other vast indications. Some studies found that different techniques might impose changes to the enamel surface that alter its topography, which in turn might influence its integrity and susceptibility to caries. Polishing, however, after this procedure is thought to be helpful to reduce these adverse effects. Aim: To evaluate the nano-topography of the enamel surfaces after interproximal reduction (IPR) and determine its influence on enamel surface roughness and examine the need for polishing to minimise these influences, when combined with topical fluoride application. Methods: A total of 60 proximal surfaces of 40 extracted maxillary premolars (10 premolars left unprepared as the control group) were reduced with different stripping instruments (discs, burs and manual strip system). The surface roughness of enamel was analysed with an atomic force microscope to determine the results quantitatively as well as qualitatively on the nanoscopic scale. One of each proximal surface was followed by polishing and fluoride varnish after the reduction. Results: The results showed that surface roughness was increased in all groups without polishing. The greatest mean roughness was recorded for the disc group (212 ±125.7), followed by the bur group (172 ±93.1) and manual strips (153.8±106.7). The difference between the groups, however, was not significant for both mean roughness ( P = 0.656) and height ( P = 0.737). The parameters were decreased after polishing in all groups but the difference between methods was not significant for both parameters ( P = 0.946 and P = 0.849); however, the mean height was reduced to nearly half the reading in the bur and manual strip method. The disc group only showed a statistically significant decrease in surface roughness with polishing ( P < 0.05). All other results were not significant. Conclusion: All methods of interproximal reduction do not influence enamel surface nanotopography significantly with and without polishing. Polishing resulted in significant reduction of surface roughness only in the disc group.

30 June 2025 in Erbil Dental Journal
Verified
Journal Article
Open access
PDF file
DBDina Jawhar Butrus
Dina Jawhar Butrus
OCOmar fawzi Chawshli
Omar fawzi Chawshli
Background: Archwire selection is critical for optimizing tooth movement and patient comfort in orthodontic treatment. However, data on archwire preferences in Iraq is limited. Objectives: To examine archwire preferences and selection practices among Iraqi orthodontists during the alignment stage of fixed orthodontic treatment. Methods: A cross-sectional survey was conducted among 83 Iraqi orthodontists using an online questionnaire. Questions assessed demographics, archwire preferences, factors influencing selection, and perceptions of treatment efficiency. Results: Traditional super-elastic nickel-titanium was the most frequently used archwire (55.4%), followed by 35°C thermo-active copper Ni-Ti (39.8%). Main factors influencing selection were achieving fast tooth movement (27.4%) and ease of manipulation (23.1%). Ease of manipulation and market availability showed statistically significant associations with archwire selection (p<0.05). Most respondents (71.1%) reported an average alignment duration of 6 months. According to 50.6% of respondents, Super-elastic Ni-Ti were the most effective in reducing treatment duration. However, 35°C copper Ni-Ti was rated as most clinically efficient (53% of respondents). Conclusion: Iraqi orthodontists prefer super-elastic NiTi archwires for alignment, influenced by biomechanical properties and practical factors. Perceptions of efficiency varied between wire types. Further research is needed to directly compare clinical outcomes with different archwires. Keywords: Orthodontic Wires Orthodontics, Corrective Dental Materials, Nickel-Titanium Alloys, Copper Alloys, Surveys and Questionnaires

11 April 2024 in Preprints.org
Verified
Preprint
Open access
PDF file
RMRebin Ali Mohammedameen
Rebin Ali Mohammedameen
OCOmar fawzi Chawshli
Omar fawzi Chawshli
Due to the retrognathic mandible, an orthodontist frequently observes skeletal class II malocclusion in growing patients. The preferred technique for analyzing and monitoring the temporomandibular joint alterations caused by the functional device is magnetic resonance imaging [MRI]. The study aimed to assess and compare changes in the articular disc's dimension and location before and following the use of various class II correctors to correct the class II molar relation using MRI technology. Methods: 39 adolescent patients aged 15-23 years old [24 girls and 15 boys] who were diagnosed with skeletal Class II division 1 malocclusion based on clearly defined criteria underwent treatment with either the power scope II [PS], Sabbagh Advanced Repositioning Appliance [SARA] and or Dynaflex [DF] with fixed appliances. For fixed functional treatment, the average length of treatment was 5-7 months. The changes in the articular disc dimension and position and condylar position were assessed. The study was done at the Department of Orthodontics at the College of Dentistry, Hawler Medical University in Erbil City. Results: Group DF has a significant effect on the condylar position index and posterior joint space on the closed mouth and disc length on both open and close mouth techniques, and in the group SARA, disc position, and condylar position index on closed mouth technique have shown that significant differences were observed. Conclusion: Class II malocclusions can be effectively corrected by fixed functional appliances. The statistical significance forward movement of the condyle in the glenoid fossa and the posterior movement of the articular disc concerning the condylar head was observed. The mechanism of action of functional appliances appears to include the forward migration of the C-GF complex.