The cooking oil fume particulate (COFP) produced by indoor cooking can harm human health seriously, and therefore requires urgent monitoring and optimization. In this paper, the kitchen cooking simulation process was established by using computational fluid dynamics (CFD) based on the fluid dynamics theory. Combined with the user defined function (UDF), the spatial and temporal distributions of COFP and carbon dioxide (CO2) during the cooking process were simulated and analyzed, respectively. Both simulation results were verified using experimental data. Moreover, this paper introduces a COFP concentration correlation function that utilizes the spatiotemporal correlation between COFP and CO2 concentrations during the cooking process. The function is based on the spatiotemporal distribution of CO2 concentration. By comparing it with traditional calculations, the proposed function is shown to achieve a remarkable 70% improvement in efficiency and maintain an accuracy rate exceeding 90%. This enables the rapid analysis and control of COFP concentration through monitoring and analyzing CO2 levels in the kitchen.
For the issues of the high temperatures and pollutant accumulation generated during kitchen cooking, this paper proposes a kitchen comfort analysis method based on the air conditioning range hood. The method comprehensively considers the thermal comfort and pollutant concentration in the kitchen and systematically investigates the influence mechanism of the air conditioning range hood’s structural parameters on kitchen comfort. Firstly, the reliability of the simulation model was verified through a comparative analysis of experimental tests and simulation data. Secondly, the temperature field, relative humidity, PM10 concentration, and Predicted Mean Vote (PMV) distribution in the kitchen were analyzed before and after air conditioning activation, confirming its positive effects and limitations. Finally, the optimal structural parameter configuration of the air conditioning range hood was explored in depth by combining orthogonal experiments with Computational Fluid Dynamics (CFD) simulations. The results show that the range hood’s exhaust airflow rate is the dominant factor affecting the PM10 concentration distribution, while the initial diffusion velocity of oil fumes has the most significant impact on reducing the kitchen’s PMV value. When the range hood’s exhaust airflow rate is 15 m3/min, the initial diffusion speed of oil fumes is 0.6 m/s, the air conditioning supply temperature is 20 °C, and the comprehensive evaluation index of kitchen comfort reaches its optimum. Under these conditions, the volume-averaged PMV value in the kitchen is 0.36, which is a decrease of 34.56%, and the spatially averaged PM10 concentration is 41.04 μg, which is a decrease of 69.49%.
To address structural redundancy and excessive vibration in a specific range hood model, this study focuses on structural lightweighting design optimization. Under strength and resonance avoidance constraints, optimization integrates experimental testing and finite element analysis. Modal analysis reveals a prominent resonance at 49.8 Hz, which coincides with the test results. Topography optimization of the impeller side plate ribs shifts its natural frequency, eliminating resonance while reducing weight significantly. Subsequently, topography optimization of key parts such as the fan housing improves stiffness, facilitating further lightweighting. Two optimization methods, direct solver and orthogonal experiment were applied to minimize the total mass under strength and dynamic constraints. Both schemes met all design requirements with weight reductions of 17.7% and 18.3%, respectively. Vibration test of the optimized design shows that accelerations at key points were reduced significantly.