High energy consumption and low aeration efficiency remain significant challenges in wastewater treatment. This study introduces a computational method that integrates the activated sludge model with Fluent (2021) to comprehensively simulate the internal operations of aeration tanks, enabling accurate modeling of biochemical mass transfer processes. Hydraulic retention times were analyzed using streamlined patterns, while low-velocity flow regions were identified across cross-sectional planes. The study systematically evaluated key water quality indicators, including dissolved oxygen, chemical oxygen demand (COD), total phosphorus (TP), total nitrogen (TN), and ammonium nitrogen (NH4+-N), across the aeration tank. A novel metric was proposed to quantify purification efficiency per unit aeration volume. Four optimized aeration schemes were designed and tested, incorporating microbubble aeration to improve flow dynamics. The optimized schemes achieved a 28% reduction in aeration energy while maintaining purification efficiency losses for COD, TP, TN, and NH4+-N below 8%. An alternative scheme reduced aeration volume by 16%, limiting efficiency losses to 5.5%. This work offers practical insights into optimizing wastewater treatment systems, providing data-driven strategies for enhancing energy efficiency and meeting stringent effluent standards.
For the issues of the high temperatures and pollutant accumulation generated during kitchen cooking, this paper proposes a kitchen comfort analysis method based on the air conditioning range hood. The method comprehensively considers the thermal comfort and pollutant concentration in the kitchen and systematically investigates the influence mechanism of the air conditioning range hood’s structural parameters on kitchen comfort. Firstly, the reliability of the simulation model was verified through a comparative analysis of experimental tests and simulation data. Secondly, the temperature field, relative humidity, PM10 concentration, and Predicted Mean Vote (PMV) distribution in the kitchen were analyzed before and after air conditioning activation, confirming its positive effects and limitations. Finally, the optimal structural parameter configuration of the air conditioning range hood was explored in depth by combining orthogonal experiments with Computational Fluid Dynamics (CFD) simulations. The results show that the range hood’s exhaust airflow rate is the dominant factor affecting the PM10 concentration distribution, while the initial diffusion velocity of oil fumes has the most significant impact on reducing the kitchen’s PMV value. When the range hood’s exhaust airflow rate is 15 m3/min, the initial diffusion speed of oil fumes is 0.6 m/s, the air conditioning supply temperature is 20 °C, and the comprehensive evaluation index of kitchen comfort reaches its optimum. Under these conditions, the volume-averaged PMV value in the kitchen is 0.36, which is a decrease of 34.56%, and the spatially averaged PM10 concentration is 41.04 μg, which is a decrease of 69.49%.