Srinath Rajagopal

Dr. Srinath Rajagopal

orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2015 in Ultrasound in Medicine & Biology
Verified
Journal Article
Closed access
SRSrinath Rajagopal
Srinath Rajagopal
NSNeelaksh Sadhoo
Neelaksh Sadhoo
BZBajram Zeqiri
Bajram Zeqiri

23 September 2024 in Sensors
Verified
Journal Article
Open access
PDF file
Hasan KorukHasan Koruk
Hasan Koruk
SRSrinath Rajagopal
Srinath Rajagopal
Although the physical properties of a structure, such as stiffness, can be determined using some statical tests, the identification of damping parameters requires a dynamic test. In general, both theoretical prediction and experimental identification of damping are quite difficult. There are many different techniques available for damping identification, and each method gives a different damping parameter. The dynamic indentation method, rheometry, atomic force microscopy, and resonant vibration tests are commonly used to identify the damping of materials, including soft materials. While the viscous damping ratio, loss factor, complex modulus, and viscosity are quite common to describe the damping of materials, there are also other parameters, such as the specific damping capacity, loss angle, half-power bandwidth, and logarithmic decrement, to describe the damping of various materials. Often, one of these parameters is measured, and the measured parameter needs to be converted into another damping parameter for comparison purposes. In this review, the theoretical derivations of different parameters for the description and quantification of damping and their relationships are presented. The expressions for both high damping and low damping are included and evaluated. This study is considered as the first comprehensive review article presenting the theoretical derivations of a large number of damping parameters and the relationships among many damping parameters, with a quantitative evaluation of accurate and approximate formulas. This paper could be a primary resource for damping research and teaching.

21 June 2021 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Open access
LHLina Hacker
Lina Hacker
JJJames Joseph
James Joseph
AIAoife M. Ivory
Aoife M. Ivory
MSMohand O. Saed
Mohand O. Saed
BZBajram Zeqiri
Bajram Zeqiri
SBSarah Elizabeth Bohndiek
Sarah Elizabeth Bohndiek
Photoacoustic imaging (PAI) standardisation demands a stable, highly reproducible physical phantom to enable routine quality control and robust performance evaluation. To address this need, we have optimised a low-cost copolymer-in-oil tissue-mimickingmaterial formulation. The base material consists of mineral oil, copolymer and stabiliser with defined Chemical Abstract Service numbers. Speed of sound c ( f ) and acoustic attenuation coefficient $\alpha $ (f) were characterised over 2–10 MHz; optical absorption $\mu _{\mathrm {a}}$ ( $\lambda $ ) and reduced scattering $\mu _{\mathrm {s}}$ ’( $\lambda $ ) coefficients over 450–900 nm. Acoustic properties were optimised by modifying base component ratios and optical properties were adjusted using additives. The temporal, thermomechanical and photo-stabilitywere studied, alongwith intra-laboratory fabrication and field-testing. c(f) could be tuned up to (1516±0.6) $\text{m}\cdot \text{s}^{-1}$ and $\alpha $ (f) to (17.4±0.3)dB $\cdot $ cm $^{-1}$ at 5 MHz. The base material exhibited negligible $\mu _{\mathrm {a}}$ ( $\lambda $ ) and $\mu _{\mathrm {s}}$ ’( $\lambda $ ), which could be independently tuned by addition of Nigrosin or TiO 2 respectively. These properties were stable over almost a year and were minimally affected by recasting. The material showed high intra-laboratory reproducibility (coefficient of variation <4% for ${c}$ ( ${f}$ ), $\alpha $ ( ${f}$ ), optical transmittance and reflectance), and good photo- and mechanical-stability in the relevant working range (20–40°C). The optimised copolymer-in-oil material represents an excellent candidate for widespread application in PAI phantoms, with properties suitable for broader use in biophotonics and ultrasound imaging standardisation efforts.

1 December 2020 in Ultrasonics
Verified
Journal Article
Open access
SRSrinath Rajagopal
Srinath Rajagopal
Ben CoxBen Cox
Ben Cox
High-frequency calibration of hydrophones is becoming increasingly important, both for clinical and scientific applications of ultrasound, and user safety. At present, the calibrations available routinely to the user community extend to 60 MHz. However, hydrophones that can measure beyond this are available, and ultrasonic fields often contain energy at higher frequencies, e.g., generated through nonlinear propagation of high-amplitude ultrasound used for therapeutic applications, and the increasing use of higher frequencies in imaging. Therefore, there is a need for calibrations up to at least 100 MHz, to allow ultrasonic fields to be accurately characterized, and the risk of harmful bioeffects to be properly assessed. Currently, sets of focused piezoelectric transducers are used to meet the pressure amplitude and bandwidth requirements of Primary Standard calibration facilities. However, when the frequency is high enough such that the size of the ultrasound focus becomes less than the hydrophone element's diameter, the uncertainty due to spatial averaging becomes significant, and can be as high as 20% at 100 MHz. As an alternate to piezoelectric transducers, a laser-generated ultrasound calibration source was designed, fabricated, and characterized. The source consists of an optically absorbing carbon-polymer nanocomposite excited by a large-diameter 1064 nm laser pulse of 2.6 ns duration. Peak pressure amplitudes of several Mega-Pascal were readily achievable, and the signal contained measurable frequency components up to 100 MHz. The variation in the pressure amplitudes was less than 2% from its mean over a three-hour test period. The ultrasound beam was sufficiently broad that the uncertainties due to spatial averaging were negligible.

1 August 2018 in The Journal of the Acoustical Society of America
Verified
Journal Article
Closed access
PDF file
SRSrinath Rajagopal
Srinath Rajagopal
TSToby Sainsbury
Toby Sainsbury
BTBradley E. Treeby
Bradley E. Treeby
Ben CoxBen Cox
Ben Cox
The characterization of ultrasound fields generated by diagnostic and therapeutic equipment is an essential requirement for performance validation and to demonstrate compliance against established safety limits. This requires hydrophones calibrated to a traceable standard. Currently, the upper calibration frequency range available to the user community is limited to 60 MHz. However, high frequencies are increasingly being used for both imaging and therapy necessitating calibration frequencies up to 100 MHz. The precise calibration of hydrophones requires a source of high amplitude, broadband, quasi-planar, and stable ultrasound fields. There are challenges to using conventional piezoelectric sources, and laser generated ultrasound sources offer a promising solution. In this study, various nanocomposites consisting of a bulk polymer matrix and multi-walled carbon nanotubes were fabricated and tested using pulsed laser of a few nanoseconds for their suitability as a source for high frequency calibration of hydrophones. The pressure amplitude and bandwidths were measured using a broadband hydrophone from 27 different nanocomposite sources. The effect of nonlinear propagation of high amplitude laser generated ultrasound on bandwidth and the effect of bandlimited sensitivity response on the deconvolved pressure waveform were numerically investigated. The stability of the nanocomposite sources under sustained laser pulse excitation was also examined.

1 July 2021 in Ultrasonics
Verified
Journal Article
Closed access
MBMarina Bakaric
Marina Bakaric
PFPaul Fromme
Paul Fromme
AHAndrew Hurrell
Andrew Hurrell
SRSrinath Rajagopal
Srinath Rajagopal
PMPiero Miloro
Piero Miloro
BTBradley E. Treeby
Bradley E. Treeby