Khalil Kharma

Dr. Khalil Kharma


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 July 2023 in Journal of Esthetic and Restorative Dentistry
Verified
Journal Article
Closed access
Rim BourgiRim Bourgi
Rim Bourgi
Carlos Cuevas-SuárezCarlos Cuevas-Suárez
Carlos Cuevas-Suárez
WDWalter Devoto
Walter Devoto
AÁAna Josefina Monjarás Ávila
Ana Josefina Monjarás Ávila
PMPaulo Monteiro
Paulo Monteiro
Louis Saba HardanLouis Saba Hardan
Louis Saba Hardan

28 September 2023 in Polymers
Verified
Journal Article
Open access
PDF file
Rim BourgiRim Bourgi
Rim Bourgi
Louis Saba HardanLouis Saba Hardan
Louis Saba Hardan
Carlos Cuevas-SuárezCarlos Cuevas-Suárez
Carlos Cuevas-Suárez
WDWalter Devoto
Walter Devoto
CKCynthia Kassis
Cynthia Kassis
Youssef HaikelYoussef Haikel
Youssef Haikel
One of the major goals of adhesive dentistry is to improve the interaction of the already-existing adhesives with different substrates by using different application techniques. Thus, the objective of the present in vitro study was to assess the bond performance of four adhesive systems, Prime&Bond Universal (PBU), Clearfil SE Bond (CSE), OptiBond Universal (OBU), and OptiBond FL (OBFL), to dentin using various application modes: passive application (PA), active application (AA), Compo-Vibes modified application (CVM), and Compo-Vibes application (CV). Eighty extracted human molars were allocated into four groups based on the application modalities tested. The micro-tensile bond strength as well as fracture mode were tested in accordance with ISO/TS 11.405 after 24 h and 6 months of aging. Adhesive contact angle (CA) and scanning electron microscope analysis were also performed (n = 3). Statistical tests were performed with α = 0.05. After 24 h, a significant difference with a higher bond strength value was found for PBU in the AA modality and for CSE in the CVM modality (p < 0.05). However, no significant difference was shown between the techniques used among the other adhesives (OBFL and OBU). Moreover, at 24 h, only the PA demonstrated significant differences between the tested materials (p < 0.05). After 6 months, CSE, PBU, and OBU demonstrated significant differences between the techniques (p < 0.05), with a higher bond strength for CSE in AA and CVM modalities, for PBU in AA modality, and for OBU in AA and PA modalities. No significant differences were found between the techniques used among the OBFL (p > 0.05). In addition, only the CVM technique demonstrated significant differences between the tested materials after 6 months. CV and CVM showed a decreased value after aging for CSE and PBU, respectively. However, all the modalities decreased for OBU and OBFL after aging. All the adhesives showed marked resin infiltration into dentinal tubules in AA among all the modalities tested. Both universal adhesive systems (OBU and PBU) demonstrated statistically lower CA when compared to the other systems (CSE and OBFL) (p < 0.05) when applied in the PA mode. Concerning the AA mode, only CSE and OBFL were tested. The AA demonstrated lower CA values compared to the same adhesives in PA (p < 0.05). It could be concluded that the bond strength could be influenced by both materials and application techniques. It seems that the AA technique could be recommended as a gold standard for the application of an adhesive system to dentin. Plus, the CV and CVM modalities after 6 months of aging were considered stable for PBU and CSE, respectively. Consequently, the performance of these adhesive systems might vary when applied to other modalities. Future studies are needed to test this hypothesis.

24 March 2024 in Biomimetics
Verified
Journal Article
Open access
PDF file
Rim BourgiRim Bourgi
Rim Bourgi
Naji KharoufNaji Kharouf
Naji Kharouf
Carlos Cuevas-SuárezCarlos Cuevas-Suárez
Carlos Cuevas-Suárez
Monika Lukomska-SzymanskaMonika Lukomska-Szymanska
Monika Lukomska-Szymanska
KKKhalil Kharma
Khalil Kharma
Louis Saba HardanLouis Saba Hardan
Louis Saba Hardan
Solvent evaporation within an adhesive layer is a crucial step during a bonding process. The aim of this current research was to test whether the use of different air temperatures (20 °C, 40 °C, and 60 °C) for solvent evaporation improves the performance of four adhesive systems to dentin. Sixty non-carious human molar teeth were randomly prepared for micro-tensile bond strength (μTBS) tests. Four different adhesive systems, Prime&Bond Universal (PBU), OptiBond Universal (OBU), OptiBond FL (OBFL), and Clearfil SE (CSE), were applied following the manufacturer’s instructions. Three groups based on the air-drying temperature were used: solvent evaporation was performed with either of warm (40 °C), (60 °C), and cold air as control group (20 °C) for 10 s at a distance of 5 cm. In all bonded surfaces, three resin composite (Reflectys, Itena Clinical, Paris, France) layers of 2 mm thickness were built up. The resin–dentin samples were kept in distilled water at 37 °C for 24 h and 6 months, respectively, before μTBS testing. Failure analysis, scanning electron microscopy of resin–dentin bonded interface, and solvent evaporation rate were tested as secondary variables. All analyses were conducted using a significance level of α = 0.05. Bond strength (BS) values were similar among all the adhesive systems used (p > 0.05). Also, the aging factor did not affect the BS (p > 0.05). Only the factor of temperature used for solvent evaporation resulted in a statistically significant effect (p < 0.05), with the temperature of 60 °C being the highest value (p < 0.05). A failure mode evaluation revealed mostly adhesive or mixed modes of failures in all the different temperatures of air used for the solvent evaporation of each adhesive system. The thickness of the adhesive layer and the creation of resin tags varied amongst the temperatures evaluated. For all adhesive systems tested, the use of 40 °C or 60 °C air for solvent evaporation led to an increased mass loss. Warmer temperatures for solvent evaporation contributed positively to bonding performance, enhancing both the quality of the adhesive layer and its interaction with the dentin tissue. Optimizing solvent evaporation with warmer air temperatures (40 °C and 60 °C) significantly improved µTBS, offering a practical means to enhance the quality and longevity of adhesive restorations in esthetic dentistry.

2 July 2025 in Prosthesis
Verified
Journal Article
Open access
PDF file
OHOmar Hasbini
Omar Hasbini
Rim BourgiRim Bourgi
Rim Bourgi
Naji KharoufNaji Kharouf
Naji Kharouf
Carlos Cuevas-SuárezCarlos Cuevas-Suárez
Carlos Cuevas-Suárez
KKKhalil Kharma
Khalil Kharma
Louis Saba HardanLouis Saba Hardan
Louis Saba Hardan
Background: Digital dental photography is increasingly essential for documentation and smile design. This study aimed to compare the linear measurement accuracy of various smartphones and a Digital Single-Lens Reflex (DSLR) camera against digital models obtained by intraoral and desktop scanners. Methods: Tooth height and width from six different casts were measured and compared using images acquired with a Canon EOS 250D DSLR, six smartphone models (iPhone 13, iPhone 15, Samsung Galaxy S22 Ultra, Samsung Galaxy S23 Ultra, Samsung Galaxy S24, and Vivo T2), and digital scans obtained from the Helios 500 intraoral scanner and the Ceramill Map 600 desktop scanner. All image measurements were performed using ImageJ software (National Institutes of Health, Bethesda, MD, USA), and statistical analysis was conducted using one-way analysis of variance (ANOVA) with Tukey’s post hoc test (α = 0.05). Results: The results showed no significant differences in measurements across most imaging methods (p > 0.05), except for the Vivo T2, which showed a significant deviation (p < 0.05). The other smartphones produced measurements comparable to those of the DSLR, even at distances as close as 16 cm. Conclusions: These findings preliminary support the clinical use of smartphones for accurate dental documentation and two-dimensional smile design, including the posterior areas, and challenge the previously recommended 24 cm minimum distance for mobile dental photography (MDP). This provides clinicians with a simplified and accessible alternative for high-accuracy dental imaging, advancing the everyday use of MDP in clinical practice.

8 June 2023 in Coatings
Verified
Journal Article
Open access
PDF file
Louis Saba HardanLouis Saba Hardan
Louis Saba Hardan
Rim BourgiRim Bourgi
Rim Bourgi
Carlos Cuevas-SuárezCarlos Cuevas-Suárez
Carlos Cuevas-Suárez
MGMaroun Ghaleb
Maroun Ghaleb
KKKhalil Kharma
Khalil Kharma
Monika Lukomska-SzymanskaMonika Lukomska-Szymanska
Monika Lukomska-Szymanska
Recently, the use of antioxidants before the bonding of bleached enamel was considered effective for reversing the reduction in the bond strength. This article aimed to assess the influence of different sodium ascorbate (SA) presentations (liquid, gel, and semi-gel) on the composite resin–enamel bond strength after a bleaching protocol. Sound human anterior teeth were collected, cleaned, prepared for a bond strength test, and randomly allocated into groups according to the bonding procedure. Group 1 acted as a control, without bleaching treatment, and without applying an antioxidant agent. In groups 2–6, specimens were bleached using 10% carbamide peroxide. In groups 3, 4 and 5, 10% wt% SA was applied for 10 min as an antioxidant in the form of a liquid, gel, and semi-gel, respectively. In group 6, samples were bleached and immersed in fresh human saliva for 14 days. After the bleaching process, the materials were restored by means of an adhesive system and a resin composite material. The analysis revealed that the differences between the shear bond strength (SBS) between the different groups were statistically significant (p = 0.0469). The highest SBS was achieved for the group where the 10 wt% SA liquid was applied before the bonding procedures. The application of liquid 10 wt% SA might reverse the negative impact that bleaching has on the bond strength of a resin composite and enamel.

25 August 2025 in Prosthesis
Verified
Journal Article
Open access
PDF file
OHOmar Hasbini
Omar Hasbini
Rim BourgiRim Bourgi
Rim Bourgi
Naji KharoufNaji Kharouf
Naji Kharouf
Carlos Cuevas-SuárezCarlos Cuevas-Suárez
Carlos Cuevas-Suárez
KKKhalil Kharma
Khalil Kharma
Louis Saba HardanLouis Saba Hardan
Louis Saba Hardan
The authors would like to make the following corrections to the published paper
1