As an important part of power system, power transformer plays an irreplaceable role in the process of power transmission. Diagnosis of transformer’s failure is of significance to maintain its safe and stable operation. Frequency response analysis (FRA) has been widely accepted as an effective tool for winding deformation fault diagnosis, which is one of the common failures for power transformers. However, there is no standard and reliable code for FRA interpretation as so far. In this paper, support vector machine (SVM) is combined with FRA to diagnose transformer faults. Furthermore, advanced optimization algorithms are also applied to improve the performance of models. A series of winding fault emulating experiments were carried out on an actual model transformer, the key features are extracted from measured FRA data, and the diagnostic model is trained and obtained, to arrive at an outcome for classifying the fault types and degrees of winding deformation faults with satisfactory accuracy. The diagnostic results indicate that this method has potential to be an intelligent, standardized, accurate and powerful tool.
16 November 2016 in Medical & Biological Engineering & Computing
High-frequency nanosecond-pulsed electric fields were recently introduced for tumor or abnormal tissue ablation to solve some problems of conventional electroporation. However, it is necessary to study the thermal effects of high-field-intensity nanosecond pulses inside tissues. The multi-parametric analysis performed here is based on a finite element model of liver tissue with a tumor that has been punctured by a pair of needle electrodes. The pulse voltage used in this study ranges from 1 to 4 kV, the pulse width ranges from 50 to 500 ns, and the repetition frequency is between 100 kHz and 1 MHz. The total pulse length is 100 μs, and the pulse burst repetition frequency is 1 Hz. Blood flow and metabolic heat generation have also been considered. Results indicate that the maximum instantaneous temperature at 100 µs can reach 49 °C, with a maximum instantaneous temperature at 1 s of 40 °C, and will not cause thermal damage during single pulse bursts. By parameter fitting, we can obtain maximum instantaneous temperature at 100 µs and 1 s for any parameter values. However, higher temperatures will be achieved and may cause thermal damage when multiple pulse bursts are applied. These results provide theoretical basis of pulse parameter selection for future experimental researches.
13 May 2020 in Materials and Manufacturing Processes
Electromagnetic pulse welding (EMPW) is an environmentally friendly and advanced manufacturing technology. Researches find the macro-morphology of EMPW joint of sheets presents a multilayer ellipse. The EMPW experiments of Al-Cu sheets and Al-Mg sheets were carried out, both the macro-morphology and the micro-morphology showed there were collision zone, bonding zone and bonding affecting zone in the joint, presenting multilayer elliptical morphology, which was independent of material. The welded seam was in the bonding zone. The 3D multiphysics simulation results also showed that the distribution of the plastic deformation of Al sheet, Lorentz force, induced eddy current and magnetic flux density at the welded joint were all elliptical, and they presented a multilayer elliptical continuous equivalent distribution surface due to the difference of amplitude. The magnetic field edge-effect affects the distribution of the magnetic flux density, and the non-uniform distribution produces the multilayer elliptical macro-morphology, which causes the induced eddy current, Lorentz force and the deformed area of the aluminum alloy plate to be the elliptical shape. Therefore, the macro-morphology of EMPW joint of sheets is a multilayer ellipse. This work may provide theoretical support for the performance improvement of the EMPW technology.
1 August 2021 in Journal of Manufacturing Processes
The Marx circuit structure based on fast high-power semiconductor devices is the classical way of generating picosecond pulses. However, most reported studies suggest that as the number of stages in the Marx circuit increases, the output pulse amplitude tends to saturate. This has of late made high-voltage picosecond-pulse generation a challenge. In this paper, as the number of stages increases, the internal resistance of the avalanche transistor tends to decrease with increasing current flowing through the avalanche transistor. A step-by-step wiring and debugging of the avalanche transistor-based Marx circuit demonstrates this experimentally. That is, for a certain range in the number of stages, saturation of the output pulse amplitude for the Marx circuit of avalanche transistors is not apparent. Introducing a parallel structure for the transistors not only increases the current level of the entire circuit but also further reduces the equivalent resistance of the avalanche transistors, thereby improving the output efficiency. Drawing on microstrip transmission theory, and combining the Marx circuit and avalanche transistor parallel structure, component parameters and circuit topology of the picosecond-pulse generator were redesigned, and a 30-level Marx circuit with a parallel structure of two avalanche transistors was developed. The picosecond-pulse generator outputs a pulse with adjustable voltage amplitude of 0.9-3.1 kV, a 350-ps full-width at half-maximum, a 150-ps rise time, and an adjustable high-stability repetition rate of up to 10 kHz. The number of pulses is precisely controlled. The generator is an all-solid-state compact device with high frequency suitable for research needs.
8 June 2023 in Journal of Materials Research and Technology