Zhongyong Zhao

Prof. Zhongyong Zhao

orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2018 in Ceramics International
Verified
Journal Article
Closed access
QZQu Zhou
Qu Zhou
WCWeigen Chen
Weigen Chen
LXLingna Xu
Lingna Xu
RKRajesh Kumar
Rajesh Kumar
YGYingang Gui
Yingang Gui
SZShiping Zhu
Shiping Zhu

1 August 2019 in IEEE Access
Verified
Journal Article
Open access
JLJiangnan Liu
Jiangnan Liu
ZZZhongyong Zhao
Zhongyong Zhao
CTChao Tang
Chao Tang
CYChenguo Yao
Chenguo Yao
CLChengxiang Li
Chengxiang Li
SISyed Islam
Syed Islam
As an important part of power system, power transformer plays an irreplaceable role in the process of power transmission. Diagnosis of transformer’s failure is of significance to maintain its safe and stable operation. Frequency response analysis (FRA) has been widely accepted as an effective tool for winding deformation fault diagnosis, which is one of the common failures for power transformers. However, there is no standard and reliable code for FRA interpretation as so far. In this paper, support vector machine (SVM) is combined with FRA to diagnose transformer faults. Furthermore, advanced optimization algorithms are also applied to improve the performance of models. A series of winding fault emulating experiments were carried out on an actual model transformer, the key features are extracted from measured FRA data, and the diagnostic model is trained and obtained, to arrive at an outcome for classifying the fault types and degrees of winding deformation faults with satisfactory accuracy. The diagnostic results indicate that this method has potential to be an intelligent, standardized, accurate and powerful tool.

13 September 2017 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
ZZZhongyong Zhao
Zhongyong Zhao
CYChenguo Yao
Chenguo Yao
CLChengxiang Li
Chengxiang Li
SISyed Islam
Syed Islam
Frequency response analysis (FRA) has recently been developed as a widely accepted tool for power transformer winding mechanical deformation diagnosis, and has proven to be effective and powerful in many cases. However, there still exist problems regarding the application of FRA. FRA is a comparative method in which the measured FRA signature should be compared with its fingerprint. Small differences of FRA signatures in certain frequency bands might be produced by external disturbance, which hinders fault diagnosis. Additionally, the existing correlation coefficient indicator recommended by power industry standards cannot reflect key information of signatures, namely the extreme points. This paper proposes an improved FRA based on binary morphology and extreme point variation. Binary morphology is first introduced to extract the certain frequency bands of signatures with significant difference. A composite indicator of extreme point variation is adopted to realize the diagnosis of fault level. A ternary diagram is constructed by the area proportions of the binary image to identify winding faults, which has a potential to realize cluster analysis of fault types.

1 May 2018 in Applied Surface Science
Verified
Journal Article
Closed access
YGYingang Gui
Yingang Gui
CTChao Tang
Chao Tang
QZQu Zhou
Qu Zhou
LXLingna Xu
Lingna Xu
ZZZhongyong Zhao
Zhongyong Zhao
XZXiaoxing Zhang
Xiaoxing Zhang

25 August 2014 in IEEE Transactions on Dielectrics and Electrical Insulation
Verified
Journal Article
Closed access
CYChenguo Yao
Chenguo Yao
ZZZhongyong Zhao
Zhongyong Zhao
YCYu Chen
Yu Chen
Xiaozhen ZhaoXiaozhen Zhao
Xiaozhen Zhao
ZLZhaojiong Li
Zhaojiong Li
GWGang Wei
Gang Wei
Transformer winding deformation is common among all sorts of transformer failures. Cumulative deformation can eventually burgeon into catastrophic faults and result in entire network outage. It is possible to detect the early signs of faults with continuous online monitoring transformer. However, frequency response analysis (FRA) is considered to be a useful and accurate tool for sufficient detection. This paper aims at proposing a novel diagnostic system for online monitoring power transformer winding deformation based on FRA. In order to realize online monitoring transformer winding, the system uses the capacitive coupling method to inject controllable nanosecond pulses, which function as the excitation signal of winding, and to obtain the response signal. This proposed method may extend frequency range for analysis and perhaps could early detect minor winding movement and looseness. Transformer experiments show great prospect in the application of the system.

1 July 2020 in Electric Power Systems Research
Verified
Journal Article
Closed access
JNJianqiang Ni
Jianqiang Ni
ZZZhongyong Zhao
Zhongyong Zhao
STShan Tan
Shan Tan
YCYu Chen
Yu Chen
CYChenguo Yao
Chenguo Yao
CTChao Tang
Chao Tang