Zhangxuan Hu

Zhangxuan Hu

Auto-generated profile, based on publicly available information

Zhangxuan Hu

Center for Biomedical Imaging Research, Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing, China

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2020 in NeuroImage
Verified
Journal Article
Open access
ZHZhangxuan Hu
Zhangxuan Hu
YWYishi Wang
Yishi Wang
ZZZhe Zhang
Zhe Zhang
JZJieying Zhang
Jieying Zhang
HZHuimao Zhang
Huimao Zhang
GHGuo Hua
Guo Hua
A distortion correction method for single-shot EPI was proposed. Point-spread-function encoded EPI (PSF-EPI) images were used as the references to correct traditional EPI images based on deep neural network. The PSF-EPI method can obtain distortion-free echo planar images. In this study, a 2D U-net based network was trained to achieve the distortion correction of single-shot EPI (SS-EPI) images, using PSF-EPI images as targets in the training stage. Anatomical T2W-TSE images were also fed into the network to improve the quality of the results. The applications in diffusion-weighted images were used as examples in this work. The network was trained on data acquired on healthy volunteers and tested on data of both healthy volunteers and patients. The corrected EPI images from the proposed method were also compared with those from field-mapping and top-up based distortion correction methods. Experimental results showed that the proposed method can correct for EPI distortions better than both the field-mapping and top-up based methods, and the results were close to the distortion-free images from PSF-EPI. Additionally, inclusion of T2W-TSE images helped improve distortion correction of the SS-EPI images without contaminating the output noticeably. The experiments with patients and different MRI platforms demonstrated the generalization feasibility of the proposed method preliminarily. Through the correction of diffusion-weighted images, the proposed deep-learning based method was demonstrated to have the feasibility to correct for the distortion of EPI images.

4 February 2020 in Magnetic Resonance in Medicine
Verified
Journal Article
Closed access
PDF file
QZQiang Zhang
Qiang Zhang
PSPan Su
Pan Su
ZCZhensen Chen
Zhensen Chen
YLYing Liao
Ying Liao
SCShuo Chen
Shuo Chen
HCHuijun Chen
Huijun Chen

13 August 2016 in Magnetic Resonance in Medicine
Verified
Journal Article
Closed access
PDF file
ZHZhangxuan Hu
Zhangxuan Hu
XMXiaodong Ma
Xiaodong Ma
TTTrong‐Kha Truong
Trong‐Kha Truong
ASAllen W. Song
Allen W. Song
GHGuo Hua
Guo Hua

7 March 2019 in Magnetic Resonance in Medicine
Verified
Journal Article
Closed access
PDF file
ZHZhangxuan Hu
Zhangxuan Hu
YWYishi Wang
Yishi Wang
ZDZijing Dong
Zijing Dong
GHGuo Hua
Guo Hua

27 August 2025 in Imaging Neuroscience
Verified
Journal Article
Open access
ZHZhangxuan Hu
Zhangxuan Hu
SPSébastien Proulx
Sébastien Proulx
GHGrant A. Hartung
Grant A. Hartung
DGDaniel E. P. Gomez
Daniel E. P. Gomez
JCJingyuan E. Chen
Jingyuan E. Chen
JPJonathan R. Polimeni
Jonathan R. Polimeni
Functional MRI (fMRI) tracks brain activity through the associated hemodynamic changes via neurovascular coupling. Neurons communicate with the microvessels of the parenchyma to initiate a hemodynamic response, and these microvessels then communicate with upstream arterioles and arteries. The role of the larger feeding arteries—far upstream from the site of neuronal activity—in coordinating this response is incompletely understood, yet is important for the interpretation of fMRI. Functional Transcranial Doppler (fTCD) can noninvasively measure blood velocity changes in a subset of the largest macrovessels, albeit with poor spatial resolution, whereas existing functional MR angiography (fMRA) methods can assess blood velocity in mid-sized macrovessels but still lack the temporal resolution required to capture dynamic responses. This study aims to propose a new, quantitative fMRA method for measuring blood velocity responses in individual vessels in humans at high spatiotemporal resolution. A dynamic functional phase-contrast MRA approach was developed to quantify responses evoked by visual stimuli in the “P2” segment of the posterior cerebral artery (PCA), located ~6 cm away from primary visual cortex. The achieved temporal resolution is comparable to that of conventional blood-oxygenation-level-dependent (BOLD) fMRI, enabling block-design stimulation paradigms similar to those used in conventional fMRI studies. The temporal and spatial properties of the blood velocity responses were evaluated using both long- and short-duration visual stimuli presented to either the full visual field or a single hemifield. Robust responses were measured on both 3T and 7T clinical MRI scanners, and an approximately 3.3 ± 1.2 cm/s increase in the blood velocity in the targeted segment was observed, which is roughly a 10% increase from baseline. Visual hemifield stimulation generated a measurable blood velocity response only in the contralateral cerebral hemisphere, indicating that systemic physiological changes occurring with stimulation cannot account for the observed response, suggesting that they instead reflect neurovascular coupling initiated in the visual cortex. The observed arterial blood velocity response is consistent with a downstream reduction in microvascular resistance and may represent a passive response rather than an active vessel dilation at the targeted arterial segment. The proposed method has the potential to extend the capability of commonly used approaches, such as fTCD, in clinical applications.

25 September 2024 in Magnetic Resonance in Medicine
Verified
Journal Article
Closed access
PDF file
ZHZhangxuan Hu
Zhangxuan Hu
ABAvery Berman
Avery Berman
ZDZijing Dong
Zijing Dong
WGWilliam A. Grissom
William A. Grissom
TRTimothy G. Reese
Timothy G. Reese
JPJonathan R. Polimeni
Jonathan R. Polimeni