Paulo Antunes

Prof. Dr. Paulo Antunes

Physics Department, University of Aveiro, Aveiro, Portugal
+1
orcid

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 December 2018 in Sensors
Verified
Journal Article
Open access
PDF file
Nélia AlbertoNélia Alberto
Nélia Alberto
Maria de Fátima DominguesMaria de Fátima Domingues
Maria de Fátima Domingues
Carlos MarquesCarlos Marques
Carlos Marques
PAPaulo Andre
Paulo Andre
Paulo AntunesPaulo Antunes
Paulo Antunes
Magnetic field sensing is an important issue for many application areas, such as in the military, industry and navigation. The current sensors used to monitor this parameter can be susceptible to electromagnetic interferences, however due to their advantages over the traditional sensors, the optical fiber devices could be an excellent alternative. Furthermore, magnetic fluid (MF) is a new type of functional material which possesses outstanding properties, including Faraday effect, birefringence, tunable refractive index and field dependent transmission. In this paper, the optical fiber magnetic field sensors using MF as sensing element are reviewed. Due to the extensive literature, only the most used sensing configurations are addressed and discussed, which include optical fiber grating, interferometry, surface plasmon resonance (SPR) and other schemes involving tailored (etched, tapered and U-shaped) fibers.

30 August 2016 in Sensors
Verified
Journal Article
Open access
PDF file
SNSusana Novais
Susana Novais
MNMicael Nascimento
Micael Nascimento
LGLorenzo Grande
Lorenzo Grande
Maria de Fátima DominguesMaria de Fátima Domingues
Maria de Fátima Domingues
Paulo AntunesPaulo Antunes
Paulo Antunes
João De Lemos PintoJoão De Lemos Pinto
João De Lemos Pinto
The integration of fiber Bragg grating (FBG) sensors in lithium-ion cells for in-situ and in-operando temperature monitoring is presented herein. The measuring of internal and external temperature variations was performed through four FBG sensors during galvanostatic cycling at C-rates ranging from 1C to 8C. The FBG sensors were placed both outside and inside the cell, located in the center of the electrochemically active area and at the tab-electrode connection. The internal sensors recorded temperature variations of 4.0 ± 0.1 °C at 5C and 4.7 ± 0.1 °C at 8C at the center of the active area, and 3.9 ± 0.1 °C at 5C and 4.0 ± 0.1 °C at 8C at the tab-electrode connection, respectively. This study is intended to contribute to detection of a temperature gradient in real time inside a cell, which can determine possible damage in the battery performance when it operates under normal and abnormal operating conditions, as well as to demonstrate the technical feasibility of the integration of in-operando microsensors inside Li-ion cells.

18 August 2009 in IEEE Sensors Journal
Verified
Journal Article
Closed access
Paulo AntunesPaulo Antunes
Paulo Antunes
HLHugo F. T. Lima
Hugo F. T. Lima
Nélia AlbertoNélia Alberto
Nélia Alberto
Hugo RodriguesHugo Rodrigues
Hugo Rodrigues
PPPedro M. F. Pinto
Pedro M. F. Pinto
PAPaulo Andre
Paulo Andre
In this study, the implementation of an optical accelerometer unit based on fiber Bragg gratings, suitable to monitor structures with frequencies up to 45 Hz, is reported. The developed optical system was used to estimate the structure eigenfrequencies of a steel footbridge, with a total length of 300 m, over the Sao Pedro Creek, located at University of Aveiro Campus, in Portugal. The acceleration records measured with this solution are compared with those obtained by traditional commercial electronic devices, revealing a root-mean-square error of 2.53 times 10-5 G.

25 September 2019 in Optics Letters
Verified
Journal Article
Closed access
PDF file
TPTiago Paixão
Tiago Paixão
FAFrancisco Araújo
Francisco Araújo
Paulo AntunesPaulo Antunes
Paulo Antunes
In this Letter, we report on a simple, but highly sensitive sensor based on two intrinsic Fabry–Perot interferometers (FPIs) inscribed in a standard single-mode optical fiber. A brief theoretical study on the Vernier effect is presented, in which a simulation of the sensitivity magnification factor dependence on the FPI’s length is performed. Based on the simulation results, the FPIs were fabricated using a custom micromachining setup that integrates a near-infrared femtosecond laser and a motorized XYZ platform. Using the Vernier effect, sensitivities of 145 pm/με and 927 pm/°C were obtained for strain and temperature, respectively. The sensor’s performance combined with its versatile and customizable configuration allows real-time and in situ strain and temperature monitoring under harsh environments.

1 November 2017 in IEEE Sensors Journal
Verified
Journal Article
Closed access
Camilo Arturo Rodríguez DíazCamilo Arturo Rodríguez Díaz
Camilo Arturo Rodríguez Díaz
Arnaldo Leal-JuniorArnaldo Leal-Junior
Arnaldo Leal-Junior
PAPaulo Andre
Paulo Andre
Paulo AntunesPaulo Antunes
Paulo Antunes
Maria Jose PontesMaria Jose Pontes
Maria Jose Pontes
MRMoises R. N. Ribeiro
Moises R. N. Ribeiro
This paper proposes a fiber optic liquid level sensor system based on a silica fiber Bragg grating embedded into an epoxy resin diaphragm coupled to a temperature reference sensor, used to compensate the temperature cross-sensitivity for improving the liquid level measurement accuracy. The proposed system was tested in an industrial water tank with heating and recirculation. The results demonstrated a temperature cross-sensitivity reduction, enhancing the liquid level measurement thermal stability by a factor of nine, when compared with some single head sensor configurations reported in literature. Our system presents high linearity ( $R>0.999$ ), superior sensitivity (2.8 pm/mm), and much lower temperature related error (1.04 mm/°C), when compared with the other diaphragm-based sensors recently reported in the literature.

27 June 2012 in Sensors
Verified
Journal Article
Open access
PDF file
SCSandra Correia
Sandra Correia
Paulo AntunesPaulo Antunes
Paulo Antunes
EPEdison Pecoraro
Edison Pecoraro
PLPatrícia P. Lima
Patrícia P. Lima
Humberto VarumHumberto Varum
Humberto Varum
PAPaulo Andre
Paulo Andre
In this work we proposed a relative humidity (RH) sensor based on a Bragg grating written in an optical fiber, associated with a coating of organo-silica hybrid material prepared by the sol-gel method. The organo-silica-based coating has a strong adhesion to the optical fiber and its expansion is reversibly affected by the change in the RH values (15.0–95.0%) of the surrounding environment, allowing an increased sensitivity (22.2 pm/%RH) and durability due to the presence of a siliceous-based inorganic component. The developed sensor was tested in a real structure health monitoring essay, in which the RH inside two concrete blocks with different porosity values was measured over 1 year. The results demonstrated the potential of the proposed optical sensor in the monitoring of civil engineering structures.