Folke Dencker

Mr. Folke Dencker


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 June 2020 in Sensors
Verified
Journal Article
Open access
PDF file
DKDaniel Klaas
Daniel Klaas
Rico OttermannRico Ottermann
Rico Ottermann
FDFolke Dencker
Folke Dencker
MWMarc Christopher Wurz
Marc Christopher Wurz
New sensor and sensor manufacturing technologies are identified as a key factor for a successful digitalisation and are therefore economically important for manufacturers and industry. To address various requirements, a new sputter coating system has been invented at the Institute of Micro Production Technology. It enables the deposition of sensor systems directly onto technical surfaces. Compared to commercially available systems, it has no spatial limitations concerning the maximum coatable component size. Moreover, it enables a simultaneous structuring of deposited layers. Within this paper, characterisation techniques, results and challenges concerning directly deposited thin film strain gauges with the new sputter coating system are presented. Constantan (CuNiMn 54/45/1) and NiCr 80/20 are used as sensor materials. The initial resistance, temperature coefficient of resistance and gauge factor/k-factor of quarter-bridge strain gauges are characterised. The influence of a protective layer on sensor behaviour and layer adhesion is investigated as well. Moreover, the temperature compensation quality of directly deposited half-bridge strain gauges is evaluated, optimised with an external trimming technology and benchmarked against commercial strain gauges. Finally, the suitability for high-temperature strain measurement is investigated. Results show a maximum operation temperature of at least 400 °C, which is above the current state-of-the-art of commercial foil-based metal strain gauges.

14 January 2022 in Experimental Mechanics
Verified
Journal Article
Open access
PDF file
SHSteffen Heikebrügge
Steffen Heikebrügge
Rico OttermannRico Ottermann
Rico Ottermann
BBBernd Breidenstein
Bernd Breidenstein
MWMarc Christopher Wurz
Marc Christopher Wurz
FDFolke Dencker
Folke Dencker
Background: Commonly, polymer foil-based strain gauges are used for the incremental hole drilling method to obtain residual stress depth profiles. These polymer foil-based strain gauges are prone to errors due to application by glue. For example zero depth setting is thus often erroneous due to necessary removal of polymer foil and glue. This is resulting in wrong use of the calibration coefficients and depth resolution and thus leading to wrong calculations of the obtained residual stress depth profiles. Additionally common polymer foil-based sensors are limited in their application regarding e.g. exposure to high temperatures. Objective: This paper aims at a first step into the qualification of directly deposited thin film strain gauges for use with the incremental hole drilling method. With the directly deposited sensors, uncertainties regarding the determination of calibration coefficients and zero depth setting due to the absence of glue can be reduced to a minimum. Additionally, new areas of interest such as the investigation of thermally sprayed metallic layers can be addressed by the sensors due to their higher temperature resilience and their component inherent minimal thickness. Methods: For the first time, different layouts of directly deposited thin film strain gauges for residual stress measurements were manufactured on a stainless steel specimen. Strain measurements during incremental hole drilling using a bespoke hole drilling device were conducted. Residual stress depth profiles were calculated using the Integral method of the ASTM E837 standard. Afterwards, strain measurements with conventional polymer foil-based strain gauges during incremental hole drilling were conducted and residual stress depth profiles were calculated accordingly. Finally the obtained profiles were compared regarding characteristic values. Results: The residual stress depth profiles obtained from directly deposited strain gauges generally match the ones obtained from conventional polymer foil based strain gauges. With the novel strain gauges, zero depth setting is simplified due to the absence of glue and polymer foil. With the direct deposition, a wide variety of rosette designs is possible, enabling a more detailed evaluation of the strain field around the drilled hole. Conclusions: The comparative analysis of the obtained residual stress depth profiles shows the general feasibility of directly deposited strain gauges for residual stress measurements. Detailed investigations on uncertainty sources are still necessary.

1 July 2025 in Applied Physics Reviews
Verified
Journal Article
Open access
MGM. Gersemann
M. Gersemann
ARA. Rajagopalan
A. Rajagopalan
MAM. Abidi
M. Abidi
PBP. Barbey
P. Barbey
ASA. Sabu
A. Sabu
SAS. Abend
S. Abend
Quantum technology became a new tool for navigation based on measuring accelerations and rotations. However, the full potential of atom interferometers that operate with ultracold atoms has not yet been exploited. This paper presents current developments in the field of generation and application of Bose–Einstein condensates for inertial navigation. It covers the advancements in the form of atom chip and compact vacuum technology, classical sensor hybridization, and a multi-axis atom interferometry technique. In addition, the synergies of combining quantum sensors with classical inertial measurement units and their implications for navigation trajectories are discussed.

27 September 2022 in Machines
Verified
Journal Article
Open access
PDF file
Rico OttermannRico Ottermann
Rico Ottermann
TSTobias Steppeler
Tobias Steppeler
FDFolke Dencker
Folke Dencker
MWMarc Christopher Wurz
Marc Christopher Wurz
In the context of intelligent components in industrial applications in the automotive, energy or construction sector, sensor monitoring is crucial for security issues and to avoid long and costly downtimes. This article discusses component-inherent thin-film sensors for this purpose, which, in contrast to conventional sensor technology, can be applied inseparably onto the component’s surface via sputtering, so that a maximum of information about the component’s condition can be generated, especially regarding deformation. This article examines whether the sensors can continue to generate reliable measurement data even after critical component loads have been applied. This extends their field of use concerning plastic deformation behavior. Therefore, any change in sensor properties is necessary for ongoing elastic strain measurements. These novel fundamentals are established for thin-film constantan strain gauges and platinum temperature sensors on steel substrates. In general, a k-factor decrease and an increase in the temperature coefficient of resistance with increasing plastic deformation could be observed until a sensor failure above 0.5% plastic deformation (constantan) occurred (1.3% for platinum). Knowing these values makes it possible to continue measuring elastic strains after critical load conditions on a machine component in terms of plastic deformation. Additionally, a method of sensor-data fusion for the clear determination of plastic deformation and temperature change is presented.

5 August 2023 in The International Journal of Advanced Manufacturing Technology
Verified
Journal Article
Open access
PDF file
LSLukas Steinhoff
Lukas Steinhoff
Rico OttermannRico Ottermann
Rico Ottermann
FDFolke Dencker
Folke Dencker
MWMarc Christopher Wurz
Marc Christopher Wurz
Precision machining is becoming more and more important with the increasing demands on surface quality for various components. This applies, for example, to mirror components in micro-optics or cooling components in microelectronics. Copper is a frequently used material for this purpose, but its mechanical properties make it difficult to machine. In this study, a process strategy for finishing copper surfaces with batch-manufactured micro-grinding tools in an electrochemically assisted grinding process is demonstrated. The tool heads are manufactured from a polyimide-abrasive-suspension and silicon as a carrier substrate using microsystems technology. The matching shafts are milled from aluminium. The tools are then used on pure copper and oxidised copper surfaces. By using finer abrasives grains (1.6–2.4 µm instead of 4–6 µm) than previously, similar surface roughness values could be achieved (Ra = 0.09 ± 0.02 µm, Rz = 1.94 ± 0.73 µm) with the same grinding process. An optimised grinding process that combines the use of rough and fine tools, on the other hand, achieves significantly better surface finishes in just four grinding iterations (Ra = 0.02 ± 0.01 µm, Rz = 0.83 ± 0.21 µm). In order to achieve a further increase in surface quality, this optimised grinding process is combined with the anodic oxidation of the copper workpieces. The surface modification is done to increase the machinability of the surface by creating an oxide layer. This is confirmed by the results of scratch tests carried out, which showed less force acting on the tool during machining with the oxide layer than with a pure copper surface. To realise this within the machine tool, an electrochemical cell is shown that can be integrated into the machine so that the oxidation can be carried out immediately before the grinding process. The copper layers produced inside the electrochemical cell in the machine tool show similar characteristics to the samples produced outside. Processing the oxidised samples with the optimised grinding process led to a further reduction of about 17% in the Rz values (Ra = 0.03 ± 0.01 µm, Rz = 0.69 ± 0.20 µm). The combination of the shown grinding process and the integration of anodic oxidation within the machine tool for the surface modification of copper workpieces seems to be promising to achieve high surface finishes.

18 August 2022 in Journal of Vacuum Science & Technology B
Verified
Journal Article
Open access
PDF file
LDLeonard Frank Diekmann
Leonard Frank Diekmann
AKAlexander Kassner
Alexander Kassner
FDFolke Dencker
Folke Dencker
MWMarc Christopher Wurz
Marc Christopher Wurz
The industrial use of quantum sensors requires further miniaturization of the experimental peripherals, i.e., the high vacuum chamber, laser technology, and control electronics. A central part of the high vacuum chamber is the maintenance of vacuum conditions. For this purpose, a prototype of a compact, i.e., miniaturized, ultrahigh vacuum pump in the form of a nonevaporable getter (NEG) pump at a wafer level (MEMS), is developed within the scope of this work. With regard to the basic conditions of the functionality of the NEG, a miniaturized heating plate with temperature sensors is analytically and numerically developed, constructed, and characterized in an ultrahigh vacuum test stand. This is followed by the integration of the NEG into the existing system, which, in connection with the characterization of material-specific parameters, enables a first correlation of heat input and pumping power. Thus, performance data of the getter-MEMS under high-vacuum confinement confirm its usability for quantum sensors. In addition, optimization potentials are shown with regard to all partial aspects of the MEMS.