Yerzhan Aisayev

Mr. Yerzhan Aisayev


Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 May 2024 in Energies
Verified
Journal Article
Open access
PDF file
YAYerzhan Aisayev
Yerzhan Aisayev
KTKazhybek Tergemes
Kazhybek Tergemes
AZAlgazy Zhauyt
Algazy Zhauyt
ASAnd Saken Sheryazov
And Saken Sheryazov
KBKairat Bakenov
Kairat Bakenov
Since the creation of the first parallel electrical power systems around the world, the rotor angle stability of synchronously operating generators has been one of the most crucial and challenging problems. In modern electricity networks, including in Kazakhstan, where renewable energy technologies are rapidly emerging, the issue of stability takes on even greater importance due to the technical shortcomings of inverter-based generation. In this framework, an analysis of rotor angle transient stability was carried out when replacing existing synchronous generators with doubly fed induction generators under a certain pre-emergency mode. A critical proportion of active power generation by DFIG units was identified at which transient stability can still be maintained due to the sufficient stored kinetic energy of the synchronous machines remaining in operation. In addition, two simple solutions were investigated to improve transient stability, such as an increased time of the automatic reclosure operation and the use of special load-shedding automation. Finally, this paper proposes a novel type of flexible smart-grid automation that is capable of monitoring the main operating parameters and issuing control actions depending on inertia, the availability of wind resources, and the load of the system as a whole. For this analysis, a real power system from the Mangystau region in Kazakhstan was considered, and the PowerWorld software 23 was used.

29 January 2024 in Preprints.org
Verified
Preprint
Open access
PDF file
YAYerzhan Aisayev
Yerzhan Aisayev
KTKazhybek Tergemes
Kazhybek Tergemes
AZAlgazy Zhauyt
Algazy Zhauyt
ASAnd Saken Sheryazov
And Saken Sheryazov
KBKairat Bakenov
Kairat Bakenov
Since the creation of the first parallel electrical power systems around the world, the rotor angle stability of synchronously operating generators has been one of the most crucial and challenging problems. In modern electricity networks, involving Kazakhstani, where the renewable energy technologies are rapidly penetrating, and the issue of stability takes on even greater importance due to the technical shortcomings of inverter-based generation. In this framework, an analysis of rotor angle transient stability was carried out when replacing existing synchronous generators with doubly fed induction generators under a certain pre-emergency mode. A critical proportion of active power generation by DFIG units was identified at which transient stability can still be maintained due to the sufficient stored kinetic energy of the synchronous machines remaining in operation. In addition, 2 simple solutions were investigated to improve transient stability, such as an increased time of the automatic reclosure operation and the use of special load shedding automation. For the analysis, a real power system of Mangystau region in Kazakhstan was considered, and the PowerWorld software was used.