1 December 2020 in Physica Medica
Verified
Journal Article
Closed access
CGC. Ghetti
C. Ghetti
OOOrnella Ortenzia
Ornella Ortenzia
MMM. Maddalo
M. Maddalo
LAL. Altabella
L. Altabella
NSN. Sverzellati
N. Sverzellati

15 February 2018 in Radiation Protection Dosimetry
Verified
Journal Article
Closed access
PDF file
OOOrnella Ortenzia
Ornella Ortenzia
RRRaffaella Rossi
Raffaella Rossi
MBMarco Bertolini
Marco Bertolini
ANAndrea Nitrosi
Andrea Nitrosi
CGC Ghetti
C Ghetti
The aim of this article was to characterise the performance of four different digital breast tomosynthesis (DBT) systems in terms of dose and image quality parameters. One of them, GE Pristina, has never been tested before. Average glandular doses were measured both in DBT and 2D full field digital mammography mode. Several phantoms were employed to perform signal difference to noise ratio, slice sensitivity profile, slice to slice incrementation, chest wall offset, z-axis geometry, artefact spread function, low contrast detectability, contrast detail evaluations, image uniformity and in-plane MTF in chest wall-nipple and in tube-travel directions. There are many differences in DBT systems explored: the angular range, detector type, reconstruction algorithms, and the presence or not of the grid. Even if it is not simple to calculate a global figure of merit, the analysis of all the collected data can be useful in a contest of a quality assurance program to define a set of values that could be used as benchmarks.

18 February 2020 in Biomedical Physics & Engineering Express
Verified
Journal Article
Closed access
PDF file
OOOrnella Ortenzia
Ornella Ortenzia
VTValeria Trojani
Valeria Trojani
MBMarco Bertolini
Marco Bertolini
ANAndrea Nitrosi
Andrea Nitrosi
MIMauro Iori
Mauro Iori
CGCaterina Ghetti
Caterina Ghetti
The goal of this paper was the comparison of radiation dose and imaging quality before and after the Clarity IQ technology installation in a Philips AlluraXper FD20/20 angiography system using a Channelized Hotelling Observer model (CHO). The core characteristics of the Allura Clarity IQ technology are its real-time noise reduction algorithms (NRT) combined with state-of-the-art hardware; this technology allows to implement acquisition protocols able to significantly reduce patient entrance dose. To measure the system performances in terms of image quality we used a contrast detail phantom in a clinical scatter condition. A Leeds TO10 phantom has been imaged between two 10 cm thick homogeneous solid water slabs. Fluoroscopy images were acquired using a cerebral protocol at 3 dose levels (low, medium and high) with a field- of view (FOV) of 31 cm. Cineangiography images were acquired using a cerebral protocol at 2 fps. Thus, 4 acquisitions were obtained for the conventional technology and 4 acquisitions were taken after the Clarity IQ upgrade, for a total of 8 different image sets. A validated 40 Gabor channels CHO with an internal noise model compared the image sets. Human observers’ studies were carried out to tune the internal noise parameter. We showed that the CHO did not detect any significant difference between any of the image sets acquired using the two technologies. Consequently, this x–ray imaging technology provides a non-inferior image quality with an average patient dose reduction of 57% and 28% respectively in cineangiography and fluoroscopy. The Clarity IQ installation has certainly allowed a considerable improvement in patient and staff safety, while maintaining the same image quality.

20 February 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
PGPasqualina Gallo
Pasqualina Gallo
ADAndrea D'Alessio
Andrea D'Alessio
RPRiccardo Pascuzzo
Riccardo Pascuzzo
Salvatore GalloSalvatore Gallo
Salvatore Gallo
MFMaria Luisa Fumagalli
Maria Luisa Fumagalli
EMElena De Martin
Elena De Martin
To quantitatively evaluate the possible advantages of quantifying and differentiating various soft tissues using virtual monochromatic images (VMI) derived from different dual-energy computed tomography (DECT) technologies. This study involved four DECT scanners with different technologies. CIRS phantom images were acquired in single-energy (SECT) and DECT modes with each scanner. The analysis focused on five equivalent soft-tissue inserts: adipose, breast, liver, muscle, and bone (200 mg). The signal-to-noise ratio (SNR) was calculated for each equivalent soft-tissue insert. Finally, the contrasts of tissue pairs between DECT and SECT images were compared using Wilcoxon signed-rank tests adjusted for multiple comparisons. Average CT numbers and noise showed a significant difference pattern between DECT with respect to SECT for each CT scanner. Generally, energy levels of 70 keV or higher led to improved SNR in VMI for most of the equivalent soft-tissue inserts. However, energy levels of 40–50 keV showed significantly higher contrasts in most of the equivalent soft-tissue insert pairs. DECT images at low energies, especially at 40–50 keV, outperform SECT images in discriminating soft tissues across all four DECT technologies. The combined use of DECT images reconstructed at different energy levels provides a more comprehensive set of information for diagnostic and/or radiotherapy evaluation compared to SECT. Some differences between scanners are evident, depending on the DECT acquisition technique and reconstruction method.

7 April 2023 in European Journal of Radiology
Verified
Journal Article
Closed access
CGCaterina Ghetti
Caterina Ghetti
OOOrnella Ortenzia
Ornella Ortenzia
MBMarco Bertolini
Marco Bertolini
GSGiada Sceni
Giada Sceni
NSNicola Sverzellati
Nicola Sverzellati
MMMichele Maddalo
Michele Maddalo

22 March 2024 in Physica Medica
Verified
Journal Article
Closed access
CGCaterina Ghetti
Caterina Ghetti
OOOrnella Ortenzia
Ornella Ortenzia
LPLaura Pagan
Laura Pagan
PGPaola Golinelli
Paola Golinelli
ANAndrea Nitrosi
Andrea Nitrosi
MBMarco Bertolini
Marco Bertolini