Hybrid high voltage direct current transmission (HVDC) can avoid commutation failure of line commutated converter based HVDC (LCC-HVDC) and high costs from modular multilevel converter based HVDC (MMC-HVDC). The uncontrollability of reactive power from LCC results in the control performance of hybrid HVDC that is not comparable to MMC-HVDC. To address this shortcoming, a mathematical model with all AC and DC side characteristics of a three-terminal hybrid HVDC system is established. Then, the quantitative relationship between the reactive power, AC bus voltage, and control variables of three converter stations is revealed. Through this analysis, a coordinated control strategy that can achieve continuous and precise control of reactive power and AC bus voltage is proposed. This strategy is achieved by utilizing the self-regulating capabilities of the converter stations. Besides, the DC voltage is ensured to remain within a reasonable range through the coordinated operation of capacitor banks. Moreover, error feedback and gamma-kick are added to make the control objective more accurate. Finally, the simulation results indicate that the proposed reactive power coordination control strategy demonstrates ideal control performance.
27 October 2020 in IEEE Transactions on Industrial Electronics
Many methods have been studied to balance the capacitor voltage of the cascaded H-bridge rectifier (CHBR). However, these balancing control methods will fail while the difference of the DC-load connected in each cell exceeds the operating limitation. Therefore, it is necessary to analyze and optimize the limitation of the balancing control quantitatively to avoid the failure of the control system. In this paper, the voltage balancing limitation (VBL) is quantitatively derived and the stable operation region (SOR) is analyzed. Moreover, essential factors affecting the balancing ability are screened out. Then, the VBL and balancing dynamics of two typical methods are elaborated. And three novel methods are proposed to improve the balancing dynamics and extend the VBL. The effects of the five methods are compared. Finally, the correctness and effectiveness of the theoretical calculation and optimization methods of VBL are verified by the simulation and experimental tests. The work of this paper can provide a theoretical reference for the system parameter design of CHBR and the alternative control scheme under extreme load conditions.
9 December 2021 in IEEE Transactions on Power Electronics
For N-cells cascaded H-bridge (CHB) inverters based on unipolar double frequency phase-shifted pulsewidth modulation (PS-PWM), the output voltage is distorted and its harmonics are difficult to be suppressed under unbalanced conditions (different dc voltages and/or modulation indices). This article proposes a closed-loop harmonic suppression scheme based on the PS-PWM, and the scheme is easily implemented in the dq frame to adaptively adjust the displacement angles of the triangular carriers. The harmonic content can be suppressed to its possible minimum value without the limitation of the operational point by the proposed method. The adjustment rules of displacement angles and the harmonic suppression principle are presented in detail. This method can effectively restrain harmonic magnitudes without the limitation of the cells number and does not require complicated trigonometric function calculations or optimization algorithms. Moreover, the principle of symmetrical sideband harmonic suppression is also discussed. The effectiveness of the proposed method is verified by a downscale test platform of the single-phase CHB inverter.
18 April 2022 in IEEE Transactions on Power Electronics
Direct current (dc) voltage sensor in each cell of the cascaded H-bridge rectifier (CHBR) is traditionally indispensable for capacitor voltage balancing control. The cost of dc sensors will increase with the number of cells. This letter proposes a strategy for dc-voltage digital sampling based on sliding window recursive least square (RLS), which employs only one voltage sensor. Sliding window RLS is used to decouple voltage information within one sampling interval. For the actual situation where the modulation waves of cells are different, this method owns faster updating rate and higher detection precision compared to the existing multisampling method. A downscale test platform of the single-phase CHBR is built to verify the correctness and effectiveness of the proposed method. The result shows that better current quality and steadier dc voltage are achieved.
8 September 2020 in IEEE Journal of Emerging and Selected Topics in Power Electronics
The harmonic transfer of the modular multilevel converter (MMC) leads to the harmonics intersection between the AC- and DC- sides and introduces additional harmonics, which worsen the power quality. Especially, the low-order harmonics, which are difficult to filter out, may cause harmonic resonance and the aging of equipment. In this paper, the mechanism of harmonic transfer for MMC is revealed more easily and clearly based on the relation bewteen arm currents and voltages. The successive approximation method (SAM) is extended for the quantitative analysis of harmonic transfer. A digital-iteration scheme (DIS) is proposed to derive the general quantitative expressions of harmonics transfer of the MMC. And the DIS is appropriate for both conditions with and without considering the effect of the control system. By the iterative calculation, the harmonics can be calculated more accurately, especially the inner-harmonics. The effectiveness of the quantitative analysis is verified by comparing the calculation, simulation and experiment results.