Lauri Lehmonen

Mr. Lauri Lehmonen

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2018 in Academic Radiology
Verified
Journal Article
Closed access
LLLauri Lehmonen
Lauri Lehmonen
AVAino-Maija Vuorinen
Aino-Maija Vuorinen
RKRiitta Koivuniemi
Riitta Koivuniemi
MLMarjatta Leirisalo-Repo
Marjatta Leirisalo-Repo
MHMiia Holmström
Miia Holmström
TKTouko Kaasalainen
Touko Kaasalainen

1 February 2019 in The International Journal of Cardiovascular Imaging
Verified
Journal Article
Open access
PDF file
LLLauri Lehmonen
Lauri Lehmonen
TKTouko Kaasalainen
Touko Kaasalainen
SASari Atula
Sari Atula
TMTuuli Mustonen
Tuuli Mustonen
MHMiia Holmström
Miia Holmström
Gelsolin (AGel) amyloidosis is a hereditary condition with common neurological effects. Myocardial involvement, especially strain, T1, or extracellular volume (ECV), in this disease has not been investigated before. Local myocardial effects and possible amyloid accumulation were the targets of interest in this study. Fifty patients with AGel amyloidosis were enrolled in the study. All patients underwent cardiovascular magnetic resonance imaging, including cine imaging, T1 mapping, tagging, and late gadolinium enhancement (LGE) imaging at 1.5 T. Results for volumetry, myocardial feature-tracking strain, rotation, torsion, native T1, ECV, and LGE were investigated. The population mean native T1 values in different segments of the left ventricle (LV) varied between 1003 and 1080 ms. Myocardial mean T1 was 1031 ± 37 ms. T1 was highest in the basal plane of the LV (1055 ± 40 ms), similarly to ECV (30.0% ± 4.4%). ECV correlated with native T1 in all LV segments (p < 0.005). Basal LGE was detected in 76% of patients, and mid-ventricular LGE in 32%. LV longitudinal strain was impaired (− 17.4% ± 2.6%), significantly decreasing apical rotation (p = 0.018) and concurrently myocardial torsion (p = 0.005). LV longitudinal strain correlated with mean T1 and ECV of different LV planes (p < 0.04; basal p < 0.01). Myocardial involvement in AGel amyloidosis is significant, but the effects are local, focusing on the basal plane of the LV.

4 December 2020 in Journal of Medical Imaging
Verified
Journal Article
Closed access
PDF file
JPJuha I. Peltonen
Juha I. Peltonen
TMTeemu Mäkelä
Teemu Mäkelä
LLLauri Lehmonen
Lauri Lehmonen
ASAlexey Sofiev
Alexey Sofiev
ESEero Salli
Eero Salli
<!-- *** Custom HTML *** --> Purpose: In addition to less frequent and more comprehensive tests, quality assurance (QA) protocol for a magnetic resonance imaging (MRI) scanner may include cursory daily or weekly phantom checks to verify equipment constancy. With an automatic image analysis workflow, the daily QA images can be further used to study scanner baseline performance and both long- and short-term variations in image quality. With known baselines and variation profiles, automatic error detection can be employed. Approach: Four image quality parameters were followed for 17 MRI scanners over six months: signal-to-noise ratio (SNR), image intensity uniformity, ghosting artifact, and geometrical distortions. Baselines and normal variations were determined. An automatic detection of abnormal QA images was compared with image deviations visually detected by human observers. Results: There were significant inter-scanner differences in the QA parameters. In some cases, the results exceeded commonly accepted tolerances. Scanner field strengths, or a unit being stationary versus mobile, did not have a clear relationship with the QA results. Conclusions: The variations and baseline levels of image QA parameters can differ significantly between MRI scanners. Scanner specific error thresholds based on parameter means and standard deviations are a viable option for detecting abnormal QA images.

1 July 2020 in BMC Medical Imaging
Verified
Journal Article
Open access
PDF file
LLLauri Lehmonen
Lauri Lehmonen
MJMikko Jalanko
Mikko Jalanko
MTMika Tarkiainen
Mika Tarkiainen
TKTouko Kaasalainen
Touko Kaasalainen
JKJohanna Kuusisto
Johanna Kuusisto
SSSauli Savolainen
Sauli Savolainen
Background: Left ventricle rotation and torsion are fundamental components of myocardial function, and several software packages have been developed for analysis of these components. The purpose of this study was to compare the suitability of two software packages with different technical principles for analysis of rotation and torsion of the left ventricle during systole. Methods: A group of hypertrophic cardiomyopathy (HCM) patients (N = 14, age 43 ± 11 years), mutation carriers without hypertrophy (N = 10, age 34 ± 13 years), and healthy relatives (N = 12, age 43 ± 17 years) underwent a cardiovascular magnetic resonance examination, including spatial modulation of magnetization tagging sequences in basal and apical planes of the left ventricle. The tagging images were analyzed offline using a harmonic phase image analysis method with Gabor filtering and a non-rigid registration-based free-form deformation technique. Left-ventricle rotation and torsion scores were obtained from end-diastole to end-systole with both software. Results: Analysis was successful in all cases with both software applications. End-systolic torsion values between the study groups were not statistically different with either software. End-systolic apical rotation, end-systolic basal rotation, and end-systolic torsion were consistently higher when analyzed with non-rigid registration than with harmonic phase-based analysis (p < 0.0001). End-systolic rotation and torsion values had significant correlations between the two software (p < 0.0001), most significant in the apical plane. Conclusions: When comparing absolute values of rotation and torsion between different individuals, software-specific reference values are required. Harmonic phase flow with Gabor filtering and non-rigid registration-based methods can both be used reliably in the analysis of systolic rotation and torsion patterns of the left ventricle.

3 October 2019 in Magnetic Resonance Materials in Physics, Biology and Medicine
Verified
Journal Article
Open access
PDF file
PYPekka Ylitalo
Pekka Ylitalo
LLLauri Lehmonen
Lauri Lehmonen
KLKirsi Lauerma
Kirsi Lauerma
MHMiia Holmström
Miia Holmström
OPOlli Pitkänen-Argillander
Olli Pitkänen-Argillander
EJEero Jokinen
Eero Jokinen
Objectives: Postoperative patients with tetralogy of Fallot (TOF) are often compromised by chronic pulmonary regurgitation and chronic right ventricular volume load. We sought to determine whether pulmonary regurgitation (PR) would affect right and left ventricle (RV and LV) strain. Materials and methods: This cross-sectional analysis included 40 patients who had TOF with surgical repair, with an average follow-up period of 11.8 ± 3.0 years. Altogether, 44 healthy volunteers with similar age and gender distribution were recruited. A cardiovascular magnetic resonance imaging study with feature tracking analysis was performed on all patients and controls. Results: RV peak longitudinal strain was increased in TOF patients with PR > 30 ml/m2 when compared to those with PR < 30 ml/m2 (− 22.5% ± 2.7% vs − 19.7% ± 3.5%, p = 0.018) and controls (p = 0.007). PR volume correlated with peak RV longitudinal strain (R = − 0.37, p = 0.030) and peak RV longitudinal strain rate (systolic: R = 0.37, p = 0.03; diastolic: R = 0.39, p = 0.021). The peak RV circumferential strain, from base to apex, increased more than in healthy controls (apex-base difference 7.6% ± 4.2% vs 3.3% ± 2.4%, p < 0.0001). Conclusions: Pediatric patients with TOF and a severe pulmonary regurgitation show an enhanced longitudinal strain when compared to patients with milder regurgitation or to control subjects. In addition, mean RV circumferential strain of the patients is significantly enhanced compared to healthy individuals.

24 January 2022 in Cardiology
Verified
Journal Article
Closed access
PDF file
PPPauli Pöyhönen
Pauli Pöyhönen
JKJouni Kuusisto
Jouni Kuusisto
JPJani Pirinen
Jani Pirinen
HRHeli Räty
Heli Räty
LLLauri Lehmonen
Lauri Lehmonen
VJVesa Järvinen
Vesa Järvinen
Purpose: There is growing evidence that paradoxical embolism through patent foramen ovale (PFO) is a cause for cryptogenic stroke. However, it is still unclear why the foramen ovale fails to close after birth. We studied whether the 3D relations between the atrial septum (AS) and the inferior vena cava (IVC) are associated with PFO. Methods: We recruited 30 patients (18–49 years) with a first-ever cryptogenic stroke and 30 age- and sex-matched stroke-free controls. Using cardiac magnetic resonance, an approach to evaluate the 3D relations between the AS and the IVC was developed. The presence of interatrial right-to-left shunt was evaluated with transesophageal echocardiography (TEE) in patients and transcranial Doppler in controls. Results: Of 30 patients, 29 underwent successful TEE, of which 12 (41%) had a shunt. Patients with a shunt had a greater mean 3D angle (γ) between the atrial septal plane and the vector from the orifice of the IVC to the middle of the AS compared with patients without a shunt (45 ± 9° vs. 36 ± 8°, p = 0.017). Of 30 controls, 12 (40%) had a shunt and a greater mean γ compared with controls without a shunt (47 ± 8° vs. 37 ± 10°, p = 0.007). In a pooled analysis, 24 (41%) of 59 subjects with a shunt had a mean γ of 46 ± 9° compared with subjects without a shunt of 37 ± 9° (p < 0.001). Conclusions: More perpendicular orientation of the atrial septal plane to the orifice of the IVC is associated with PFO, possibly by directing the IVC flow to PFO.