Minimally invasive staged segmental artery coil embolization (MIS2ACE) is an emerging technology for priming of the paraspinous collateral network prior to open or endovascular thoracoabdominal aortic aneurysm (TAAA) repair. Its safety and efficacy have been previously proven in various experimental settings and confirmed in numerous multicentric pilot studies for open and endovascular repair. MIS2ACE is safe and has the potential to decisively reduce the risk of postoperative paraplegia, the most devastating complication of open and endovascular TAAA repair, still affecting up to 20% of patients. Up to now, MIS2ACE has been clinically implemented with excellent results, and is currently being investigated in the international, multicenter, randomized controlled trial PAPAartis, funded by the German Research foundation, and the European Union. MIS2ACE can be performed under local anesthesia, enabling continuous monitoring of neurological function, and in case of clinical signs of imminent ischemia, preemptive interruption of the procedure. A thorough evaluation of preoperative computed tomography (CT) imaging for identification of open and accessible segmental arteries (SAs) is critical. Segmental artery occlusion can be achieved with either micro coils, or vascular plugs. A maximum number of seven SAs is currently recommended to be occluded in the same session, and a minimum interval of 5 days should be awaited between either two MIS2ACE sessions or between MIS2ACE and the final repair. Adjuvant side-effects of MIS2ACE are the reduction in segmental back-bleeding during open repair leading to harmful steal phenomenon and the reduction of the incidence of type II endoleaks in endovascular repair. Current contraindications for MIS2ACE are emergency cases, hostile anatomy, and a shaggy aorta. Other neuroprotective adjuncts such as cerebrospinal fluid (CSF) drainage, permissive hypertension, motor-evoked potentials (MEP)/somato-sensory evoked potentials (SSEP) and monitoring of paraspinous muscle oxygenation by near-infrared spectroscopy should also be applied independent of prior MIS2ACE procedure.
Objective: Minimally invasive approaches are being used increasingly in cardiac surgery and applied in a wider range of operations, including complex aortic procedures. The aim of this study was to examine the safety and feasibility of a partial upper sternotomy approach for isolated elective aortic root replacement (a modified Bentall procedure). Methods: We performed a retrospective analysis of 768 consecutive patients who had undergone isolated Bentall surgery between January 2000 and January 2021 at our institution, with the exclusion of re-operations, endocarditis, acute aortic dissections, and root replacement with major concomitant procedures such as multi-valve or coronary bypass surgery. A total of 98 patients were operated on via partial sternotomy (PS) and were matched 2:1 to 196 patients operated on via full sternotomy (FS). Results: The procedure time was 12 min longer in the PS group (205 min vs. 192.5 min in the FS group, p = 0.002), however, cardiopulmonary bypass and aortic cross-clamp times were comparable between groups. Eight PS-procedures were converted to full sternotomy, predominantly for bleeding complications (n = 6). Re-exploration for acute bleeding was necessary in 11% of the PS group and 4.1% of the FS group (p = 0.02). Five FS patients and none in the PS group required emergency coronary bypass grafting for postoperative coronary obstruction (p = 0.2). PS patients were hospitalized for a significantly shorter period (9.5 days vs. 10.5 days in the FS group, respectively). There were no significant differences regarding in-hospital (p = 0.4) and mid-term mortality (p = 0.73), as well as for other perioperative complications. Conclusions: Performing Bentall operations via partial upper sternotomy is associated with similar perfusion and cross-clamp times, as well as overall mortality, when compared to a full sternotomy approach. A low threshold for conversion to full sternotomy should be accepted if limited access proves insufficient for the handling of intraoperative complications, particularly bleeding.
Objective: Acute aortic dissection is a rare but frequently fatal aortic catastrophe with high morbidity and mortality. Especially in pregnant patients, acute dissection is often misdiagnosed putting two lives on the line. Due to its scarcity, only case reports have been reported. The aim of this study is to analyze the time of aortic dissection during the course of pregnancy and the outcome of emergency surgery in pregnant women with and without hereditary connective tissue disorder. Methods: We retrospectively reviewed all acute aortic dissections (type A and B) who underwent emergency aortic surgery at our institution between 1994 and 2022 and identified 13 patients with acute aortic dissection during pregnancy or directly postpartum. Mann–Whitney U and Fisher’s exact tests were used for statistical analysis. Results: Of the 13 included patients, 5 had a genetic syndrome. These patients were significantly younger at the time of dissection and at an earlier stage of pregnancy (second trimester). Even though operative and in-house mortality was zero, we lost one patient on postoperative day 14 due to rupture of the aortic root after transfer to another hospital. Survival of neonates was 77% including two aborted pregnancies. Conclusions: Surgical treatment of acute aortic dissection during pregnancy can be performed with excellent operative mortality for the mothers and satisfying survival of their neonates. In patients with genetic syndrome, dissection occurs during the early second trimester, whereas non-syndromic patients experience acute dissection in the late third trimester. Long-term follow-up is essential for timely re-intervention, if needed.
Background: Atrial fibrillation, the world's predominant cardiac arrhythmia, frequently emerges as a complication post-cardiac surgery, leading to serious outcomes like strokes, heart failures, and even death. Due to its often-silent nature, detecting it can be challenging. Smartwatches present a potential solution, offering screening that is more rigorous. Objective: This prospective observational study sought to assess the Withings Scanwatch's efficacy in identifying post-surgical atrial fibrillation. Methods: After cardiac surgery, patients received a Withings Scanwatch. Over a span of 24 hours, both the smartwatch's Photoplethysmography (PPG) sensor and standard telemetry kept track of any atrial fibrillation incidents. Results: At the end of the study, data from 260 patients was available for assessment. Atrial fibrillation was identified in 32 of these patients, either via telemetry or the smartwatch. Our data revealed a sensitivity of 69.0%, specificity of 98.7%, a PPV of 87.0%, and an NPV of 96.2%. Conclusions: This clinical study is the first to evaluate the PPG sensor of the Withings Scanwatch, and it shows that the Scanwatch has high accuracy in detecting atrial fibrillation. Thus, Scanwatch may support the conventional screening for atrial fibrillation, and potentially reducing complications and costs of atrial fibrillation. Because of lower than expected sensitivity this technology cannot replace conventional monitoring in postoperative patients.