Epicardial access during electrophysiology procedures offers valuable insights and therapeutic options for managing ventricular arrhythmias (VAs). The current clinical consensus statement on epicardial VA ablation aims to provide clinicians with a comprehensive understanding of this complex clinical scenario. It offers structured advice and a systematic approach to patient management. Specific sections are devoted to anatomical considerations, criteria for epicardial access and mapping evaluation, methods of epicardial access, management of complications, training, and institutional requirements for epicardial VA ablation. This consensus is a joint effort of collaborating cardiac electrophysiology societies, including the European Heart Rhythm Association, the Heart Rhythm Society, the Asia Pacific Heart Rhythm Society, the Latin American Heart Rhythm Society, and the Canadian Heart Rhythm Society.
Some of the recently released smartwatch products feature a single-lead electrocardiogram (ECG) recording capability. The reliability of obtaining 3-lead ECG with smartwatches is yet to be confirmed in a large study. This study aimed to assess the feasibility and reliability of smartwatch to obtain 3-lead ECG recordings, the classical Einthoven ECG leads I-III compared to standard ECG. To record lead I, the watch was worn on the left wrist and the right index finger was placed on the digital crown for 30 s. For lead II, the watch was placed on the lower abdomen and the right index finger was placed on the digital crown for 30 s. For lead III, the same process was repeated with the left index finger. Spearman correlation and Bland-Altman tests were used for data analysis. A total of 300 smartwatch ECG tracings were successfully obtained. ECG waves’ characteristics of all three leads obtained from the smartwatch had a similar duration, amplitude, and polarity compared to standard ECG. The results of this study suggested that the examined smartwatch (Apple Watch Series 4) could obtain 3-lead ECG tracings, including Einthoven leads I, II, and III by placing the smartwatch on the described positions.
The ultra-low-temperature cryoablation (ULTC) ablation system using −196°C N2 cryogen has been reported to create lesions with freeze duration–dependent depth titratable to over 10 mm with minimum attenuation by scar. Cryocure-VT (NCT04893317) was a first-in-human clinical trial evaluating the safety and efficacy of a novel, purpose-built ULTC catheter in endocardial ablation of scar-dependent ventricular tachycardias (VTs). This prospective, multi-centre study enrolled patients referred for de novo or second ablations of recurrent monomorphic VT of both ischaemic and non-ischaemic aetiologies. Primary safety and efficacy endpoints of the study were freedom from device- or procedure-related major adverse events (MAEs) up to 30 days post-ablation, acute non-inducibility of clinical VTs at the end of the procedure, and freedom from sustained VT or implantable defibrillator intervention at 6 months. Ultra-low-temperature cryoablation was performed in 64 patients (age 67 ± 11 years, 78% ischaemic, ejection fraction = 35 ± 10%) at 9 centres. The primary acute effectiveness endpoint was achieved in 94% (51/54) of patients in whom post-ablation induction was attempted. There were no protocol-defined MAEs; four procedure-related serious adverse events resolved without clinical sequelae. At 6-month follow-up, 38 patients (60.3%) remained VT-free, and freedom from defibrillator shock was 81.0%, with no significant difference between ischaemic and non-ischaemic cohorts. In 47 patients with defibrillator for at least 6 months prior to the ablation, the VT burden was reduced from median of 4, inter-quartile range (IQR, 1–9) to 0, IQR (0–2). In this first-in-human multi-centre experience, endocardial ULTC ablation of monomorphic VT appears safe and effective in patients with both ischaemic-cardiomyopathy and non-ischaemic-cardiomyopathy. NCT04893317.
Aim: Cardiac sympathetic denervation (CSD) has been introduced as a bailout therapy in patients with structural heart disease and refractory ventricular arrhythmias (VAs), but available data are scarce. Purpose of this study was to estimate immediate results, complications, and mid-term outcomes of CSD following recurrent VA after catheter ablation. Methods and results: Adult patients who underwent CSD in the Heart Center Leipzig from March 2017 to February 2021 were retrospectively analysed. Follow-up (FU) was executed via implantable cardioverter defibrillator (ICD) interrogation, telephone interviews, and reviewing medical records. Twenty-one patients (age 63.7 ± 14.4 years, all men, 71.4% non-ischaemic cardiomyopathy, left ventricular ejection fraction 31.6 ± 12.6%) received CSD via video-assisted thoracoscopic surgery (90.5% bilateral, 9.5% left-sided only). Indication for CSD was monomorphic ventricular tachycardia in 76.2% and ventricular fibrillation in 23.8 with 71.4% of patients presenting with electrical storm before index hospitalization. Procedure-related major complications occurred in 9.5% of patients. In-hospital adverse events not related to surgery were common (28.6%) and two patients died during the index hospital stay. During FU (mean duration 9.1 ± 6.5 months), five more patients died. Of the remaining patients, 38.5 and 76.9% were free from any VA or ICD shocks, respectively. Conclusions: The CSD showed additional moderate efficacy to suppress VAs, when performed as a bailout therapy after previously unsuccessful catheter ablation. At 9 months, it was associated with freedom of ICD shocks in two-thirds of patients. In a population with many comorbidities, the rate of CSD-related complications was acceptable, although there was an overall high risk of procedure unrelated adverse events and death.
The Apple Watch is capable of recording single-lead electrocardiograms (ECGs). To incorporate such devices in routine medical care, the reliability of such devices to obtain precordial leads needs to be validated. The purpose of this study was to assess the feasibility and reliability of a smartwatch (SW) to obtain precordial leads compared to standard ECGs. We included 100 participants (62 male, aged 62.8 ± 13.1 years) with sinus rhythm and recorded a standard 12-lead ECG and the precordial leads with the Apple Watch. The ECGs were quantitively compared. A total of 98 patients were able to record precordial leads without assistance. A strong correlation was observed between the amplitude of the standard and SW-ECGs’ waves, in terms of P waves, QRS-complexes, and T waves (all p-values < 0.01). A significant correlation was observed between the two methods regarding the duration of the ECG waves (all p-values < 0.01). Assessment of polarity showed a significant and a strong concordance between the ECGs’ waves in all six leads (91–100%, all p-values < 0.001). In conclusion, 98% of patients were able to record precordial leads using a SW without assistance. The SW is feasible and reliable for obtaining valid precordial-lead ECG recordings as a validated alternative to a standard ECG.