Ultrafine KAl(OH)2CO3 dry powder (UDWP), as a novel high-temperature-resistant ultrafine dry powder fire extinguishing agent, has garnered significant attention in the field of aviation fire protection. However, its development has been hindered by its hydrophilicity, which leads to hygroscopicity, and its tendency for re-ignition due to oil deposition. Therefore, this study employs perfluorodecyltrimethoxysilane (PFDTMS) to modify the surface of UDWP, resulting in hydrophobic and oleophobic M-UDWP. The thermal stability and hydrophobicity of M-UDWP ensure its long-term stable storage in aircraft equipment compartments, thereby reducing aircraft maintenance costs. Additionally, its oleophobicity provides excellent anti-re-ignition performance, protecting aircraft power compartments from secondary fire damage. Energy-dispersive X-ray spectroscopy (EDS), Fourier-transform infrared spectroscopy (FTIR), and X-ray photoelectron spectroscopy (XPS) analyses indicate that the PFDTMS modifier was successfully grafted onto KAl(OH)2CO3. Furthermore, M-UDWP exhibits a three-stage thermal decomposition process. The first-stage decomposition can be regarded as a single-step reaction, and the calculated kinetic parameters provide accurate predictions. Thermogravimetric analysis-Fourier transform infrared spectroscopy-mass spectrometry (TG-FTIR-MS) results reveal that M-UDWP significantly produces H2O and CO2 during thermal decomposition, which is one of its core fire extinguishing mechanisms. For the combustion of #RP-3 and #RP-5 aviation kerosene, commonly found in aircraft engine nacelles, the extinguishing times required by M-UDWP are 243 ms and 224 ms, respectively, with minimum extinguishing concentrations (MEC) of 25.9 g/m3 and 23.4 g/m3, respectively. The study of M-UDWP’s thermal stability aids in understanding its storage stability under high-temperature conditions and its fire extinguishing mechanisms in fire zones. Moreover, the research findings suggest that M-UDWP has the potential to replace Halon 1301 in aircraft engine nacelles.
In order to guide the optimization design of the pipeline network of the aircraft-fixed gas fire extinguishing system and improve its fire extinguishing performance, FLUENT software was used to simulate the influence of pipeline parameters such as diameter, length, and roughness on the release characteristics of the fire extinguishing agent. It can be found that the extinguishing agent can be divided into liquid and vapor extinguishing agents in the fire extinguishing pipeline system during the release. The spatial distribution and proportion of the liquid and vapor extinguishing agents are asymmetric. Results show that the peak value of the pressure drop rate () has a good quadratic function relationship with the pipeline diameter () and the functional relationship is which means that the peak value increased significantly with the increase in the pipeline diameter. Moreover, when the pipeline diameter is 25 , the average pressure drop rate of the vessel is about 35.02 , which is 5.97 times the value of the average pressure drop rate when the pipeline diameter is 10 . With the increase in the pipeline diameter, the release time decreases significantly, the mass flow rate increases obviously, while the gasification ratio decreases rapidly at first and then increases slightly. The pipeline length also has a significant influence on the release characteristics of the extinguishing agent. With the increase in the pipeline length, the release time and the gasification ratio increase linearly, while the mass flow rate decreases linearly. Compared with the pipeline diameter and pipeline length, the influence of the pipeline roughness on the release characteristics of the extinguishing agent is weak. With the increase in the pipeline roughness, the release time and the gasification ratio of the extinguishing agent increases slowly, while the mass flow rate decreases slowly.
The mass loss mechanisms of an aqueous film-forming foam (AF foam), an AR/AFFF water-soluble film-forming foam extinguishing agent (AR foam), and a Class A foam extinguishing agent (A foam) at different levels of thermal radiation, thermal convection, and heat conduction intensity were studied. At a relatively low thermal radiation intensity, the liquid separation rate of the AF, AR, and A foams is related to the properties of the foam itself, such as viscosity and surface/interface tension, which are relatively independent of the external radiation heat flux of the foam. At low radiation intensity (15 kW/m2 and 25 kW/m2), the liquid separation rate of the AF and A foams is relatively stable. When the heat flux intensity is 35 kW/m2, the liquid separation rate of the AF and A foams increases notably, which may be mainly due to the rapid decrease in foam viscosity. And the mass loss behavior is dominated by liquid separation in the AF, AR, and A foams under the influence of thermal radiation and thermal convection. Under the same experimental conditions, the liquid separation rate of AF is the fastest. There is no significant difference in the evaporation rates of the three kinds of foam in the same heat conduction condition. In addition, the AR and A foams usually have a 25% longer liquid separation time (t) under thermal radiation and thermal convection, and the thermal stability is better than AF foam. The temperature reached by the AF foam layer under thermal convection was lower than that of the AR and A foams, and the time for the foam layer to reach the highest temperature under heat conduction was longer than that of the AR and A foams.