Shunsuke Nakakura

Dr. Shunsuke Nakakura

orcid

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2018 in Clinical Ophthalmology
Verified
Journal Article
Open access
PDF file
SNShunsuke Nakakura
Shunsuke Nakakura
The rebound tonometer has a unique mechanism for measuring intraocular pressure (IOP) and has become popular worldwide due to its ease of use. The most notable advantages are the lack of an air-puff and need for topical anesthesia, ease of operation and transport, and the ability to use it with children. Four rebound tonometers (Icare® TA01i, Icare PRO, Icare HOME, and Icare ic100) are currently available for clinical examination. It is important to understand the characteristics of each tonometer and select the most appropriate one because the IOP values and the purpose of measurement are different. In this review, with the goal of improving the understanding of a range of tonometers, the issues with each device are discussed.

9 April 2017 in International Ophthalmology
Verified
Journal Article
Closed access
PDF file
YKYoshitake Kato
Yoshitake Kato
SNShunsuke Nakakura
Shunsuke Nakakura
NMNaoko Matsuo
Naoko Matsuo
KYKayo Yoshitomi
Kayo Yoshitomi
MHMarina Handa
Marina Handa
YKYoshiaki Kiuchi
Yoshiaki Kiuchi

1 November 2018 in American Journal of Ophthalmology
Verified
Journal Article
Closed access
KHKazunori Hirasawa
Kazunori Hirasawa
SNShunsuke Nakakura
Shunsuke Nakakura
YNYoshitaka Nakao
Yoshitaka Nakao
YFYuri Fujino
Yuri Fujino
MMMasato Matsuura
Masato Matsuura
RARyo Asaoka
Ryo Asaoka

1 July 2018 in Journal of Glaucoma
Verified
Journal Article
Closed access
HMHiroki Masumoto
Hiroki Masumoto
HTHitoshi Tabuchi
Hitoshi Tabuchi
SNShunsuke Nakakura
Shunsuke Nakakura
NINaofumi Co Ishitobi
Naofumi Co Ishitobi
MMMasayuki Miki
Masayuki Miki
HEHiroki Enno
Hiroki Enno
Purpose: To evaluate the accuracy of detecting glaucoma visual field defect severity using deep-learning (DL) classifier with an ultrawide-field scanning laser ophthalmoscope. Methods: One eye of 982 open-angle glaucoma (OAG) patients and 417 healthy eyes were enrolled. We categorized glaucoma patients into 3 groups according to the glaucoma visual field damage (Humphrey Field Analyzer 24-2 program) [early; −6 dB (mean deviation) or better, moderate; between −6 and −12 dB, and severe as mean deviation of −12 dB or worse]. In total, 558 images (446 for training and 112 for grading) from early OAG patients, 203 images (162 for training and 41 for grading) from moderate OAG patients, 221 images (176 for training and 45 for grading) from severe OAG patients and 417 images (333 for training and 84 for grading) from normal subjects were analyzed using DL. The area under the receiver operating characteristic curve (AUC) was used to evaluate the accuracy after 100 trials. Results: The mean AUC between normal versus all glaucoma patients was 0.872, the sensitivity was 81.3% and the specificity was 80.2%. In normal versus early OAG, mean AUC was 0.830, the sensitivity was 83.8% and the specificity was 75.3%. In normal versus moderate OAG, mean AUC was 0.864, sensitivity was 77.5%, and specificity was 90.2%. In normal versus severe OAG glaucoma mean AUC was 0.934, sensitivity was 90.9%, and specificity was 95.8%. Conclusions: Despite using an ultrawide-field scanning laser ophthalmoscope, DL can detect glaucoma characteristics and glaucoma visual field defect severity with high reliability.

2 December 2016 in Current Eye Research
Verified
Journal Article
Closed access
ETEtsuko Terao
Etsuko Terao
SNShunsuke Nakakura
Shunsuke Nakakura
YFYasuko Fujisawa
Yasuko Fujisawa
YFYuki Fujio
Yuki Fujio
KMKanae Matsuya
Kanae Matsuya
YKYoshiaki Kiuchi
Yoshiaki Kiuchi
Purpose: We investigated the detailed time course of conjunctival hyperemia induced by ripasudil 0.4%, a novel Rho-kinase inhibitor anti-glaucoma eye drop, in healthy subjects. Methods: We recruited 51 healthy subjects and administered ripasudil 0.4% in their right eye. We evaluated conjunctival hyperemia using slit lamp photography and measured the intraocular pressure (IOP) using the Icare PRO Rebound Tonometer at baseline and after 5, 15, 30, 60, 90, and 120 min. The conjunctival hyperemia score was graded by three independent observers on a scale of 0 (none) to 3 (severe). Additionally, we analyzed the “percent coverage” of conjunctival hyperemia by using an automated hyperemia analysis software program; this program provides the pixel coverage of the conjunctival vessels in the region of interest. Dunnett and Steel multiple comparison tests were used, as appropriate, for the subsequent analyses. Results: The conjunctival hyperemia score and percent coverage increased rapidly after the instillation of ripasudil 0.4%, peaking at 15 min (score: 1.83 ± 0.29 [mean ± SD]) and 5 min (11.6% ± 4.7%), respectively, and then gradually decreasing until 120 min (0.45 ± 0.22 and 4.7% ± 1.8%, respectively), when they reached a level that was not significantly different from the baseline values. The IOP decreased significantly compared to the baseline at 30, 60, and 90 min, based on the Dunnett test. Conclusion: Conjunctival hyperemia induced by ripasudil 0.4% peaks rapidly to moderate severity, but subsides relatively quickly.

1 July 2021 in Eye and Vision
Verified
Journal Article
Open access
PDF file
SNShunsuke Nakakura
Shunsuke Nakakura
RARyo Asaoka
Ryo Asaoka
ETEtsuko Terao
Etsuko Terao
YNYuki Nagata
Yuki Nagata
YFYasuko Fukuma
Yasuko Fukuma
YKYoshiaki Kiuchi
Yoshiaki Kiuchi
Background: This study investigated the agreement between a new rebound tonometer, IC200, and IcarePRO and Goldmann applanation tonometry (GAT). Methods: This was a prospective cross-sectional study. We measured the intraocular pressure (IOP) in 145 eyes of 145 glaucoma patients in the sitting position using GAT, IcarePRO, and IC200. IcarePRO and IC200 measurements were also obtained in the supine position. IC200 measurement was performed using two modes: single six (IC200-single) and automatic (IC200-continuous) six-measurements mode. Results: All tonometers provided high reproducibility in both positions (all intraclass correlation coefficients > 0.90), although it was highest with GAT, followed by IC200-continuous and IC200-single and then IcarePRO. In the sitting position, the mean (± SD) IOPs of GAT, IcarePRO, IC200-single, and IC200-continuous were 14.5 ± 2.9 mmHg, 13.3 ± 3.2 mmHg, 11.6 ± 3.2 mmHg, and 11.5 ± 3.2 mmHg, respectively. IOPs measured with IcarePRO or IC200 were significantly lower than those with GAT, particularly in patients with low IOP. IOPs measured with all tonometers were significantly elevated in the supine position as compared with the sitting position, but this difference was significantly greater with IC200-single and IC200-continuous compared with IcarePRO. IOP elevation was significant in eyes without bleb versus those with bleb, but this finding was not observed when IOP was measured with IcarePRO. The IOPs of the single and continuous modes of IC200 were interchangeable in both positions. Conclusions: GAT, IcarePRO, and IC200 had sufficiently high reproducibility, but measurements with IcarePRO may not be accurate in the supine position. Elevation of IOP in the supine position, especially in eyes with bleb, was more sensitively captured with IC200 than with IcarePRO. Trial registration: Japan Clinical Trials Register, No. UMIN000039982.