1 February 2019 in American Journal of Ophthalmology
1 November 2018 in American Journal of Ophthalmology
27 June 2020 in British Journal of Ophthalmology
Background/Aim: To train and validate the prediction performance of the deep learning (DL) model to predict visual field (VF) in central 10° from spectral domain optical coherence tomography (SD-OCT). Methods: This multicentre, cross-sectional study included paired Humphrey field analyser (HFA) 10-2 VF and SD-OCT measurements from 591 eyes of 347 patients with open-angle glaucoma (OAG) or normal subjects for the training data set. We trained a convolutional neural network (CNN) for predicting VF threshold (TH) sensitivity values from the thickness of the three macular layers: retinal nerve fibre layer, ganglion cell layer+inner plexiform layer and outer segment+retinal pigment epithelium. We implemented pattern-based regularisation on top of CNN to avoid overfitting. Using an external testing data set of 160 eyes of 131 patients with OAG, the prediction performance (absolute error (AE) and R2 between predicted and actual TH values) was calculated for (1) mean TH in whole VF and (2) each TH of 68 points. For comparison, we trained support vector machine (SVM) and multiple linear regression (MLR). Results: AE of whole VF with CNN was 2.84±2.98 (mean±SD) dB, significantly smaller than those with SVM (5.65±5.12 dB) and MLR (6.96±5.38 dB) (all, p<0.001). Mean of point-wise mean AE with CNN was 5.47±3.05 dB, significantly smaller than those with SVM (7.96±4.63 dB) and MLR (11.71±4.15 dB) (all, p<0.001). R2 with CNN was 0.74 for the mean TH of whole VF, and 0.44±0.24 for the overall 68 points. Conclusion: DL model showed considerably accurate prediction of HFA 10-2 VF from SD-OCT.
30 July 2019 in British Journal of Ophthalmology
Aims Corvis ST (CST) yields biomechanical corrected IOP (bIOP) which is purported to be less dependent on biomechanical properties. In our accompanied paper, it was suggested that the repeatability of bIOP is high. The purpose of the current study was to assess the relationship between intraocular pressure (IOP) measured with CST and central corneal thickness (CCT) and corneal hysteresis (CH), in comparison with IOP measured with Goldmann applanation tonometry (GAT) and the ocular response analyzer (ORA). Methods A total of 141 eyes from 141 subjects (35 healthy eyes and 106 glaucomatous eyes) underwent IOP measurements with GAT, CST and ORA. The relationships between IOP measurements (ORA-IOPg, ORA-IOPcc, CST-bIOP and GAT IOP) and biomechanical properties (CCT, CH and corneal resistance factor (CRF)) were analysed using the linear regression analysis. Results IOPg, IOPcc and GAT IOP were significantly associated with CCT (p<0.001), whereas bIOP was not significantly associated with CCT (p=0.19). IOPg, bIOP and GAT IOP were significantly associated with CH (IOPg: p<0.001; bIOP: p<0.001; GAT IOP: p=0.0054), whereas IOPcc was not significantly associated with CH (p=0.18). All of IOP records were associated with CRF (p<0.001). Conclusion The bIOP measurement from CST is independent from CCT, but dependent on CH and CRF.
1 October 2020 in American Journal of Ophthalmology
14 July 2021 in British Journal of Ophthalmology
Background/aims To validate a deep learning algorithm to diagnose glaucoma from fundus photography obtained with a smartphone. Methods A training dataset consisting of 1364 colour fundus photographs with glaucomatous indications and 1768 colour fundus photographs without glaucomatous features was obtained using an ordinary fundus camera. The testing dataset consisted of 73 eyes of 73 patients with glaucoma and 89 eyes of 89 normative subjects. In the testing dataset, fundus photographs were acquired using an ordinary fundus camera and a smartphone. A deep learning algorithm was developed to diagnose glaucoma using a training dataset. The trained neural network was evaluated by prediction result of the diagnostic of glaucoma or normal over the test datasets, using images from both an ordinary fundus camera and a smartphone. Diagnostic accuracy was assessed using the area under the receiver operating characteristic curve (AROC). Results The AROC with a fundus camera was 98.9% and 84.2% with a smartphone. When validated only in eyes with advanced glaucoma (mean deviation value < −12 dB, N=26), the AROC with a fundus camera was 99.3% and 90.0% with a smartphone. There were significant differences between these AROC values using different cameras. Conclusion The usefulness of a deep learning algorithm to automatically screen for glaucoma from smartphone-based fundus photographs was validated. The algorithm had a considerable high diagnostic ability, particularly in eyes with advanced glaucoma.