The leakage of the ship’s pipeline system will bring great risks to the engine equipment and seriously threaten the vitality of the ship. In this paper, the pipeline leakage detection and localization research are carried out based on the vibration signal generated by pipeline leakage. First, the finite element model of the pipeline is constructed to obtain the variation law of the vibration signal when the pipeline leaks are carried out. Second, the vibration signal is processed based on the variational mode decomposition (VMD) and radial basis function (RBF) neural networks. The wavelet packet threshold noise reduction is conducted before signal decomposition to improve the signal-to-noise ratio. Then, the denoised signal is decomposed by VMD. The effective component is identified by analyzing the correlation coefficient between the component and the denoised signal. The center frequency and energy of the effective component are used as feature vector to train the RBF neural network to identify and locate leakage. Finally, a pipeline leakage test platform is built under laboratory conditions. After processing the data samples collected from the test, the RBF neural network is trained to identify and locate leaks. The test sample identification results show that the leak identification and localization method based on VMD-RBF has a high accuracy.
To address the limitations inherent in traditional simulation control schemes for dual-engine parallel operation systems in diesel engines—such as protracted development cycles, suboptimal interface compatibility, insufficient real-time performance, and inadequate support for dynamic condition simulation in applications like marine power systems—this paper proposes an embedded real-time controller based on model-based design. This methodology facilitates efficient development and high-precision real-time control of parallel operation systems. A multi-domain coupled simulation model integrating diesel power and parallel control algorithms is built in MATLAB/Simulink, with optimized C code auto-generated via Embedded Coder. Hardware centers on STM32F407VE, enabling 4–20 mA speed acquisition, CAN communication, and Ethernet transmission. Experimental results indicate that the architecture shortens development cycles from 8 to 3 weeks, with 895 microseconds of simulation steps meeting 1-millisecond real-time requirements. Vessel tests achieve ±1.8 r/min synchronization error and ±1.2% load distribution error at low cost. It adapts to varied diesel power via modular substitution and supports RS485/CAN-FD. In conclusion, the controller effectively handles real-time simulated diesel engine parallel systems and excels in efficiency, compatibility, and cost, offering a viable technical pathway for modernizing parallel power systems in applications such as marine vessels and power generation.
The controllable pitch propeller hydraulic system has high constraints and nonlinearity. Due to these inherent deficiencies, the proportional–integral–derivative (PID) control algorithm cannot meet the control accuracy requirements of nonlinear systems. A control law based on a model predictive control (MPC) algorithm is designed in this paper. The gain parameters of the predictive control are optimized. The MPC and PID control systems are compared and simulated to verify the MPC controller’s effectiveness. Subsequently, the embedded controller of a controllable pitch propeller is developed. The support package for the embedded circuit board target containing an underlying driver for each interface is written by introducing the C-MEX S-Function and TLC programming language. A semi-physical simulation experiment is performed. The results show that the established controllable pitch propeller with an embedded controller displays reliable running performance, good anti-interference, and the capacity to fulfill the control function of the pitch propeller under various working conditions.
Chillers serve as the core high-energy-consuming equipment in heating, ventilation, and air conditioning (HVAC) systems. During long-term continuous operation, they tend to suffer gradual subtle degradation, with a performance deviation less than 5%. Conventional fault diagnosis methods rely on manual threshold judgment or labeled fault data, which fail to realize accurate early warning signals. In addition, existing algorithms lack multi-dimensional baseline comparisons to verify their practical engineering performance. To address these limitations, this paper proposes an unsupervised health assessment method combining an LSTM autoencoder and Euclidean distance (LSTM-AE-ED). A multi-gradient fault time-series dataset is generated via a MATLAB R2022b/Simscape mechanism model verified by both summer field measurements and refrigeration pressure-enthalpy cycles, which resolves the practical engineering challenges of scarce on-site fault samples and potential equipment damage caused by actual fault tests. The proposed model is trained solely on healthy time-series data. It extracts dynamic coupling characteristics of chillers through LSTM, constructs a dimensionless health index based on Euclidean distance in feature space, and introduces the standard deviation of health index to improve evaluation stability. Baseline comparisons with vanilla AE and single-layer LSTM are carried out. Experimental results demonstrate that the proposed method achieves an identification accuracy of 96.3% and exhibits high sensitivity to mild degradation of four typical faults, adapting to dynamic multi-working-condition scenarios. This approach requires no additional acquisition devices for derived parameters such as power consumption and COP; online assessment can be realized merely with standard temperature, pressure, and flow sensors equipped on chillers. With lightweight inference performance, it is suitable for edge monitoring terminals of chillers in data centers, providing a low-cost and practical quantitative technical scheme for predictive maintenance and hierarchical early warning signals of refrigeration equipment.