子轩 王

Dr. 子轩 王


Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 September 2024 in Energies
Verified
Journal Article
Open access
PDF file
ZLZhihan Liu
Zhihan Liu
YGYongshuai Gong
Yongshuai Gong
子王子轩 王
子轩 王
YLYingfeng Li
Yingfeng Li
DLDongxue Liu
Dongxue Liu
Hot-spot generation is critical to the performance and lifespan of photovoltaic (PV) modules; however, the underlying mechanisms of hot-spot formation have not been fully elucidated. This work conducted a localized shading test on a PV module, measured the micro-electrical characteristics and temperature distributions of both the shaded and unshaded cells, calculated the heat-source power densities, and then predicted the occurrence and locations of hot and cold spots via numerical simulations. It was found that, under an irradiance of 750 W/m2, when one cell in a PV module is shaded by 1/2, the unshaded area within the shaded cell exhibited a hot spot, with the temperature reaching up to 77.66 °C, approximately 22.5 °C higher than the surrounding cells. The intrinsic mechanism for the occurrence of the hot spot is that, compared with the unshaded cells, the unshaded portion of the shaded cell can generate an extra significantly large Joule heat power density, about 1079.62 W/m2. The reason for generating such a large Joule heat power density is that this portion is in a reverse-bias state with a high current density flowing through it, according to our measurements. In contrast, the shaded portion forms a cold spot, about 7.5 °C cooler than the surrounding cells. This is because the shaded portion can only generate a Joule heat power density of about 46.98 W/m2 due to the small reverse-bias current density flowing through it and fails to absorb heat from solar irradiance, which is about 645 W/m2. Moreover, this work demonstrates that the hot-spot temperature initially rises and then decreases with increasing shading ratio, with the highest temperatures and the most pronounced temperature changes occurring around a shading ratio of 1/2. The presented method can be also used to evaluate the performance and reliability of various other PV modules under local shading conditions.

27 March 2024 in Energies
Verified
Journal Article
Open access
PDF file
YLYingfeng Li
Yingfeng Li
ZLZhihan Liu
Zhihan Liu
DLDongxue Liu
Dongxue Liu
子王子轩 王
子轩 王
YGYongshuai Gong
Yongshuai Gong
MLMeicheng LI
Meicheng LI
Shading on photovoltaic (PV) modules due to shadows, covering, dust, etc., usually characterized as semi-transparent, will significantly affect the power generation capacity. No systematic study has considered the impact of semi-transparent coverings on the power generation capacity of PV modules. This paper covers a single cell in the PV module using a covering with a transmittance of 18.55% and systematically investigates its impact on the power generation capacity. The open-circuit voltage (Voc) of the PV module is nearly unaffected by semi-transparent coverings because the covered cell can be considered as working at a lower irradiance and thus can output a voltage close to that of the uncovered cell. The short-circuit current (Isc) is significantly affected by coverings because it is co-contributed by the photocurrent (evaluated based on the covering ratio R and transmittance) and the reverse bias current ΔIsc (the covered cell is in a reverse bias state). The ΔIsc increases with R because more charge accumulates at the bi-ends of the covered cell; but, it decreases at full covering, which implies that in a partially covered case the uncovered part contributes more to ΔIsc than the covered part. The fill factor (FF) of the PV module first increases and then decreases with R, as the equivalent resistance of the covered cell increases rapidly with R, which replaces the wire resistance in dominating the series resistance of the PV module when R > 0.6. This work is of great theoretical significance in analyzing the output characteristics of PV modules under real conditions.