Stavros A. Papathanassiou

Prof. Stavros A. Papathanassiou


Research Focus & Metrics

Academic Career Length

27Years (2000-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 April 2018 in IEEE Transactions on Power Electronics
Verified
Journal Article
Open access
Efstratios BatzelisEfstratios Batzelis
Efstratios Batzelis
SPStavros A. Papathanassiou
Stavros A. Papathanassiou
BPBikash C. Pal
Bikash C. Pal
The challenges of modern power systems will inevitably impose increased ancillary service requirements to photovoltaic (PV) plants in the future, including operating reserves. Recent studies have investigated methods to maintain active power reserves without energy storage in the standard case of uniform illumination. In this paper, this functionality is extended to partial shading conditions, often encountered in PV systems. A new control scheme is proposed that permits operation at a reduced power level, estimating at the same time the shading conditions and maximum available power. This is achieved by applying a least-squares curve fitting algorithm on voltage and current measurements, without relying on any irradiance or temperature sensors. To the best of our knowledge, this is the first power reserves control scheme for PV systems under partial shading presented in the literature. The robustness and effectiveness of the proposed method are validated under rapidly changing shading conditions through simulations and experimental tests on a 2-kW PV system prototype.

16 March 2018 in IEEE Transactions on Sustainable Energy
Verified
Journal Article
Closed access
GPGeorgios Psarros
Georgios Psarros
EKEleni G. Karamanou
Eleni G. Karamanou
SPStavros A. Papathanassiou
Stavros A. Papathanassiou
This paper analyzes the operating and economic benefits anticipated from the introduction of centrally managed battery energy storage systems (BESSs) in noninterconnected island (NII) grids with high renewable energy source (RES) penetration. A mixed integer linear programming based generation management model is developed to simulate the operation of NII systems with and without BESS facilities. The impact of BESS energy and power capacity sizing is discussed, showing that the main contribution of storage lies in the provision of fast response reserves that facilitate the integration of increased intermittent RES generation. A feasibility analysis is then performed, considering BESS facilities either as independent storage investments or as facilities being developed in conjunction with new wind power capacity. The levelized cost of energy or reserves is calculated to evaluate the required remuneration to ensure investment viability.

20 August 2021 in Energies
Verified
Journal Article
Open access
PDF file
PDPantelis Dratsas
Pantelis Dratsas
GPGeorgios Psarros
Georgios Psarros
SPStavros A. Papathanassiou
Stavros A. Papathanassiou
The objective of this paper is to evaluate the contribution of energy storage systems to resource adequacy of power systems experiencing increased levels of renewables penetration. To this end, a coherent methodology for the assessment of system capacity adequacy and the calculation of energy storage capacity value is presented, utilizing the Monte Carlo technique. The main focus is on short-duration storage, mainly battery energy storage systems (BESS), whose capacity values are determined for different power and energy configurations. Alternative operating policies (OPs) are implemented, prioritizing system cost or reliability, to demonstrate the significant effect storage management may have on its contribution to system adequacy. A medium-sized island system is used as a study case, applying a mixed integer linear programming (MILP) generation scheduling model to simulate BESS and system operation under each OP, in order to determine capacity contribution and overall performance in terms of renewable energy sources (RES) penetration, system operating cost and BESS lifetime expectancy. This study reveals that BESS contribution to system adequacy can be significant (capacity credit values up to ~85%), with energy capacity proving to be the most significant parameter. Energy storage may at the same time enhance system reliability, reduce generation cost and support RES integration, provided that it is appropriately managed; a combined reliability-oriented and cost-driven management approach is shown to yield optimal results.

19 July 2023 in IEEE Access
Verified
Journal Article
Open access
Apostolos PapakonstantinouApostolos Papakonstantinou
Apostolos Papakonstantinou
AKApostolos I. Konstanteas
Apostolos I. Konstanteas
SPStavros A. Papathanassiou
Stavros A. Papathanassiou
Seeking 100% renewable energy source (RES) penetration in low-inertia, isolated grids presents major challenges, including frequency control and stability. This is the case in small island systems relying on variable RES and pumped-hydro storage, where the limited ramping capabilities of hydro turbines compromise their frequency response. In this study, solutions are examined to allow the operation of such systems under 100% RES conditions. The Greek island of Ikaria is used as a study case, supplied by a hybrid RES-storage facility, consisting of hydroelectric units, a pumping facility and a wind farm. Solutions under study include the implementation of deflector control to allow provision of fast reserves by the Pelton hydro turbines, primary reserves provision by the wind farm, the enhancement of the variable speed pump control to contribute to primary frequency regulation, and, at a further step, the installation of battery energy storage to provide fast response for effective frequency regulation. All solutions are comparatively assessed via simulation to demonstrate that the proposed deflector control allows effective frequency regulation, albeit at the detriment of energy efficiency, whereas the variable speed pumps may also contribute to primary regulation in case of contingencies. It is battery storage that would decisively enhance frequency control and security of operation, while also allowing for improved tracking of wind power variations in normal operation; best results are achieved when batteries are combined with the other supplementary regulation measures, allowing a reduced battery capacity.


9 February 2023 in IEEE Transactions on Power Systems
Verified
Journal Article
Closed access
PDPantelis Dratsas
Pantelis Dratsas
GPGeorgios Psarros
Georgios Psarros
SPStavros A. Papathanassiou
Stavros A. Papathanassiou
This paper proposes a novel real-time redispatch method for energy storage systems (ESSs) in resource adequacy studies. In case of real-time contingencies, a realistic operating profile is generated for ESSs to enhance system reliability by mitigating loss of load events, while maintaining their market schedule to the extent possible. Contrary to the standard approaches in the literature, the proposed method neither adopts a perfect foresight for future events, such as generator failures, nor does it resort to “greedy” adequacy-oriented management strategies which are detached from normal operation. Instead, storages follow a market-driven schedule, being suitably redispatched during real-time operation when necessary for adequacy reasons, subject to their energy and power capacity constraints. The redispatch method is deterministically formulated through a sequence of logical conditions and is integrated into a stochastic adequacy assessment model built upon Monte Carlo technique. Multiple battery energy storage configurations have been examined, with the Greek power system serving as a realistic case study, to evaluate the method against others available in the literature and calculate the capacity value of battery ESS.