Marcelo Fernando Valdiviezo

Mr. Marcelo Fernando Valdiviezo

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 March 2024 in Energies
Verified
Journal Article
Open access
PDF file
Jorge Maldonado-CorreaJorge Maldonado-Correa
Jorge Maldonado-Correa
MVMarcelo Fernando Valdiviezo
Marcelo Fernando Valdiviezo
EAEstefania Artigao
Estefania Artigao
SMSergio Martin-Martinez
Sergio Martin-Martinez
Emilio Gomez-LazaroEmilio Gomez-Lazaro
Emilio Gomez-Lazaro
It is common knowledge that wind energy is a crucial, strategic component of the mix needed to create a green economy. In this regard, optimizing the operations and maintenance (O&M) of wind turbines (WTs) is key, as it will serve to reduce the levelized cost of electricity (LCOE) of wind energy. Since most modern WTs are equipped with a Supervisory Control and Data Acquisition (SCADA) system for remote monitoring and control, condition-based maintenance using SCADA data is considered a promising solution, although certain drawbacks still exist. Typically, large amounts of normal-operating SCADA data are generated against small amounts of fault-related data. In this study, we use high-frequency SCADA data from an operating WT with a significant imbalance between normal and fault classes. We implement several resampling techniques to address this challenge and generate synthetic generator fault data. In addition, several machine learning (ML) algorithms are proposed for processing the resampled data and WT generator fault classification. Experimental results show that ADASYN + Random Forest obtained the best performance, providing promising results toward wind farm O&M optimization.

4 November 2020 in Wind Engineering
Verified
Journal Article
Closed access
PDF file
Jorge Maldonado-CorreaJorge Maldonado-Correa
Jorge Maldonado-Correa
MVMarcelo Fernando Valdiviezo
Marcelo Fernando Valdiviezo
MVMarlon Santiago Viñán-Ludeña
Marlon Santiago Viñán-Ludeña
CSCarlos Samaniego-Ojeda
Carlos Samaniego-Ojeda
MRMarco Rojas-Moncayo
Marco Rojas-Moncayo
Wind energy is a non-programmable form of generation, hence, accurate and reliable wind energy prediction is of great importance for the efficient operation of wind farms. This article presents a study for the prediction of active power for the Villonaco Wind Farm (VWF), located in southern Ecuador at approximately 2700 m above sea level. Through the use of artificial neural networks, experimental tests are developed based on the models of Multi-Layer Perceptron (MLP), Long Short-Term Memory (LSTM), and Convolutional Neural Network (CNN) to obtain a hybrid model that fits the best characteristics of the individual models. Data from the active power SCADA (Supervisory Control and Data Acquisition) system for the years 2014 to 2018 are used to train and validate the models. Hybrid model is presented as the most appropriate option by the values obtained, viz., the mean absolute error (MAE), the mean squared error (MSE), and mean absolute percentage error (MAPE) that were 0.1365, 0.0974, and 144.26, respectively, outperforming to the others wind power forecast models.

23 August 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
JCJoel Stiven Torres Cabrera
Joel Stiven Torres Cabrera
Jorge Maldonado-CorreaJorge Maldonado-Correa
Jorge Maldonado-Correa
MVMarcelo Fernando Valdiviezo
Marcelo Fernando Valdiviezo
EAEstefania Artigao
Estefania Artigao
SMSergio Martin-Martinez
Sergio Martin-Martinez
Emilio Gomez-LazaroEmilio Gomez-Lazaro
Emilio Gomez-Lazaro
The imminent depletion of oil resources and increasing environmental pollution have driven the use of clean energy, particularly wind energy. However, wind turbines (WTs) face significant challenges, such as critical component failures, which can cause unexpected shutdowns and affect energy production. To address this challenge, we analyzed the Supervisory Control and Data Acquisition (SCADA) data to identify significant differences between the relationship of variables based on data reconstruction errors between actual and predicted values. This study proposes a hybrid short- and long-term memory autoencoder model with multihead self-attention (LSTM-MA-AE) for WT converter fault detection. The proposed model identifies anomalies in the data by comparing the reconstruction errors of the variables involved. However, more is needed. To address this model limitation, we developed a fault prediction system that employs an adaptive threshold with an Exponentially Weighted Moving Average (EWMA) and a fixed threshold. This system analyzes the anomalies of several variables and generates fault warnings in advance time. Thus, we propose an outlier detection method through data preprocessing and unsupervised learning, using SCADA data collected from a wind farm located in complex terrain, including real faults in the converter. The LSTM-MA-AE is shown to be able to predict the converter failure 3.3 months in advance, and with an F1 greater than 90% in the tests performed. The results provide evidence of the potential of the proposed model to improve converter fault diagnosis with SCADA data in complex environments, highlighting its ability to increase the reliability and efficiency of WTs.

3 March 2020
Verified
Book Chapter
Closed access
PDF file
Jorge Maldonado-CorreaJorge Maldonado-Correa
Jorge Maldonado-Correa
MVMarcelo Fernando Valdiviezo
Marcelo Fernando Valdiviezo
JJJuan Carlos Solano Jiménez
Juan Carlos Solano Jiménez
MRMarco Rojas
Marco Rojas
CSCarlos Samaniego-Ojeda
Carlos Samaniego-Ojeda

1 January 2022
Verified
Book Chapter
Closed access
PDF file
Jorge Maldonado-CorreaJorge Maldonado-Correa
Jorge Maldonado-Correa
JJJuan Carlos Solano Jiménez
Juan Carlos Solano Jiménez
MRMarco Rojas
Marco Rojas
JCJosé Cuenca
José Cuenca
MVMarcelo Fernando Valdiviezo
Marcelo Fernando Valdiviezo