Leonardo Santana de Oliveira Dias

Dr. Leonardo Santana de Oliveira Dias

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2023 in REM - International Engineering Journal
Verified
Journal Article
Open access
PDF file
GSGilvan Sá
Gilvan Sá
MBMarco Antonio Braga
Marco Antonio Braga
LALuiz Antonio Pinto e Almeida
Luiz Antonio Pinto e Almeida
LDLeonardo Santana de Oliveira Dias
Leonardo Santana de Oliveira Dias
ACAlan de Souza Cunha
Alan de Souza Cunha
RTRicardo Luiz Teixeira Telles
Ricardo Luiz Teixeira Telles
The geotechnical monitoring of tailings dams combined with a suitable application of geophysical electrical methods can improve their structure evaluation, allowing several correlations between direct analyses and the resistivity anomaly pattern. Considering this synergy, twenty-three electrical resistivity sections (ERT) were acquired along the beach, abutments, and central part of a dam, totalizing 10,776 m of dataset. After the interpretation of each ERT section, comparing the anomaly ranges with the water level meters measurements, three resistivity zones were defined: Zones of low resistivity ( 357 ohm-m), interpreted as dry zones, and regions with intermediate resistivity values, located between these limits. The groundwater surface generated from the interpretation of the electrical resistivity dataset and the groundwater surface acquired from the water level gauges were almost coincident. On the right abutment, the conductive anomalies showed remarkable continuity, suggesting a high moisture content in this region with strong gradients (200 mV) directed towards the zone of low resistivity values identified in the sections. The analysis showed a robust correlation of the ERT data with localized physical geotechnical measurements, valuable for monitoring dam integrity, overseeing the structure's response to climate and operational changes, and ultimately mitigating the risks of failure. The results of this study support the adoption of a seasonal 4D electrical resistivity survey as an effective tool to monitor and manage surface and high humidity zones, key indicators of dam integrity throughout the entire structure.

14 October 2022 in Anuário do Instituto de Geociências
Verified
Journal Article
Open access
PDF file
LDLeonardo Santana de Oliveira Dias
Leonardo Santana de Oliveira Dias
MBMarco Antonio da Silva Braga
Marco Antonio da Silva Braga
ACAlan De Souza Cunha
Alan De Souza Cunha
GOGerrit Olivier
Gerrit Olivier
DMDaniel Monteiro Machado
Daniel Monteiro Machado
Mining induced seismicity can expose tailings dams to ground motions with potential to trigger a failure, if the structure reaches a certain level of vibrations that could exceed the seismic coefficient design criteria from pseudostatic analysis. Despite the cited risk, mainly for dams that are closer to open pits, few dams in Brazil are monitored by microseismic systems, and there are no references in the literature about continuous seismic monitoring both in open pit (source) and tailings dam, which represents the motivation of this paper. A microseismic system was commissioned in Cajati Mine, São Paulo, to record seismic events continuously in an array of 16 geophones (14 Hz and 4.5 Hz), installed in boreholes near the open pit (12 sensors) and in the dam (4 sensors), has measured values of PGA (Peak Ground Acceleration) and PGV (Peak Ground Velocity) related to 2,972 induced events from rock removal in the open pit. During the period monitored, the total of 109 events have triggered sensors in both structures, producing 920 seismograms, with the highest values of PGA and PGV of 0.0135 m/s2 (0.1358% of g) and 0.0892 mm/s. The highest PGA value is 36 times lower than the vertical coefficient of 3% of g defined by Brazilian technical standard to dam design criteria, normally used in common pseudostatic analysis from geotechnical engineers. A routine microseismic monitoring brings a new set of valuable actionable data and information to support the management of geotechnical tailings dams’ risks, under the conditions of vibrations induced by mining production.

5 December 2021 in Brazilian Journal of Geophysics
Verified
Journal Article
Closed access
PDF file
LDLeonardo Santana de Oliveira Dias
Leonardo Santana de Oliveira Dias
MBMarco Antônio Silva Braga
Marco Antônio Silva Braga
ACAlan de Souza Cunha
Alan de Souza Cunha
GOGerrit Olivier
Gerrit Olivier
RFRodrigo Peluci de Figueiredo
Rodrigo Peluci de Figueiredo
Ground motions caused by routine blasting activities represent a concern for mining companies, that face the challenge of producing without causing critical damage to tailings dams, mine pit slopes and waste piles. Few dams in Brazil are monitored by microseismic systems, and there are no references in the literature about monitoring in open pit mine and dam. In order to analyze the ground motion data induced by blats and their relationship with dam stability, it was installed a seismic system, that records events continuously in an array of 16 geophones (14 Hz and 4.5 Hz), 12 installed in an open pit and 4 in a tailings dam with value measurement of Peak Ground Acceleration, Peak Ground Velocity, dominant frequency, and seismic source parameters related to blast events. In the monitored period, sensors from the open pit and dam were analyzed and all accelerations recorded showed that ∼95% of the values are lower than 0.06 m/s2, with 90% of the records with higher dominant frequency (>10 Hz), that presents lower damage potential due to the lower capacity to produce high values of displacements. The system showed the potential to add new data and information to the current dam geotechnical instrumentation.Keywords: blast-induced seismicity, microseismic monitoring, tailings dam, risk management, geotechnical monitoring plan.Ground Motions Induzidos por Desmontes em Barragem de RejeitosRESUMO. Os ground motions gerados pelas atividades rotineiras de detonação representam uma preocupação para as mineradoras, que enfrentam o desafio de produzir sem causar danos críticos às barragens de rejeitos, taludes de cava e pilhas de estéril. Poucas barragens no Brasil são monitoradas por sistemas microssísmicos e não há referências na literatura sobre monitoramento em cava e barragem. Para analisar os dados dos ground motions causados pelas detonações e a sua relação com a estabilidade de uma barragem, foi instalado um sistema de monitoramento sísmico, que registra eventos continuamente num arranjo de 16 geofones (14 Hz e 4,5 Hz), instalados 12 na cava e 4 na barragem, com medição de valores de Peak Ground Acceleration, Peak Ground Velocity, frequência dominante e parâmetros da fonte sísmica dos desmontes. No período monitorado, quando foram analisados os sensores da mina e da barragem, todas as acelerações mostraram que ∼95% dos valores são menores que 0,06 m/s2, com 90% dos registros com maior frequência dominante (> 10 Hz), que apresenta menor potencial de dano devido à menor capacidade de produzir altos valores de deslocamentos. O sistema mostrou potencial para agregar novos dados e informações à atual instrumentação geotécnica da barragem.Palavras-chave: sismicidade induzida por desmontes, monitoramento microssísmico, barragem de rejeitos, gerenciamento de risco, plano de monitoramento geotécnico.